As wind power retains a significant proportion of generation mix in the electric system, we foresee that less fossil fuel units will be on service. Under this situation, it may impact system's frequency security due to the lack of frequency support from units. To make up for such a system change, wind turbines should actively provide frequency response upon request. For wind turbines to achieve this goal, active power output of the wind turbine should be controllable so that the generating margin could be preserved for frequency response. Therefore, the presentation of this paper will begin with the demonstration of the control scheme for the doubly fed induction generator (DFIG). Simulation results validate the effectiveness of the methodology in regulating wind power upon operator's request, while stability is assured under variant wind speeds. Following that, this paper will explore several operating strategies for DFIGs to support system frequency with less sacrifice in the wind energy production. Simulation results show that the proposed strategies can enhance regulation performance in the high wind penetrated power system.
25 November 2013 in IEEE Transactions on Power Systems
Wind power has become one of the most prominent renewable energy applications in the power industry. Its annual installation is continuously setting a record high. Due to the large portion of generation mix within the system, it is desirable to operate wind power under the automatic generation control (AGC). This issue also raises another concern on the modeling of wind farms under AGC. The traditional way of portraying wind farm production in simulation is to use an aggregated wind turbine model that is generally operated in maximum power point tracking (MPPT). This approach is not suitable for wind's participation in AGC. Therefore, more studies should be done to investigate how the individual wind turbines affect the wind farm performance under the set-point operation. This paper first illustrates the controllability of wind turbines under the set-point control. Following that, a comprehensive guidance of wind generator modeling is demonstrated to yield different approaches for developing the wind farm model. Two types of wind farm models are derived and demonstrated to portray the capability of set-point tracking under the intermittent wind condition. Associated simulations are presented and compared to show the different characteristics of these two wind farm models in depicting the set-point operation under AGC.
9 September 2009 in IEEE Transactions on Energy Conversion
As installed capacity of wind power retains a significant proportion of generation mix in the electric system, operators have the increasing expectation that wind turbines should function in some ways similar to the conventional plants. In addition to some basic capabilities to regulate reactive power for voltage support, the counterpart in active power control is also the major concern. This paper presents a control strategy to regulate active power for doubly fed induction generator under various operating conditions. Testing results showing the control performance in the simulated conditions validate the feasibility of the operation in power dispatch upon operator's request, and maintain stability under variant wind speed. Additionally, supplemental functions in generation margin assessment, in spinning reserve support, and in governor droop are presented to make the wind farm operation more like a conventional power plant.
Demand response (DR) is considered to be one of the most incentive smart grid functions to enhance power system reliability and control. For the purpose of system security, DR has been utilized to deal with contingent events. In this way, load shedding conducted by the DR program is no longer sorely considered as the last defense line to save system frequency, it should be considered as part of the available fast response resources to cooperate with spinning reserve for balancing generation and demand under some specific conditions. This paper proposes an overall frequency restoration plan considering the DR and spinning reserve. The frequency restoration is designed using the DR as the first option to intercept frequency decline for a large disturbance, followed by the scheduled spinning reserve to raise frequency back to the pre-disturbance level. The proposed scheme is especially developed to intelligently deploy DR for coordinating with different spinning reserve constraints and contingency scenarios. Tests of the proposed frequency restoration scheme are evaluated by simulation where the system data was retrieved from frequency events in a utility. Test results show that the proposed spinning reserve and DR deployment could effectively restore frequency under various contingency scenarios.
22 April 2008 in IEEE Transactions on Power Systems
With the increasing wind penetration into the power system, guidelines of the operating reserve need to be revised to ensure system security. Due to the uncertain characteristics of the wind production, the general way of the reserve management for wind integration is to provide additional reserve margin by conventional plants. Such a strategy could not only increase the operating cost but also impose additional unit stress during the frequency event. This paper presents a strategy that incorporates doubly-fed induction generator (DFIG) wind farms to actively provide primary reserve for frequency control. The wind reserve allocation according to available wind speed is proposed. An integrated system that consists of the traditional units and DFIG wind farms has been developed to assess the frequency response and generating interactions. Simulation results are discussed to illustrate the superiority of the presented strategy in reserve operation.
30 July 2013 in IEEE Transactions on Sustainable Energy
Wind energy is achieving worldwide acceptance as the most appealing renewable resource. Due to its increasing portion of generation mix, wind farms are expected to play the role similar to the traditional power plants. Down the road toward this goal, the intermittency and uncertainty of wind are the two important factors that should be solved. Today, storage systems present a very interesting alternative to deal with the wind variability. Among various storage types, the hydrogen system is showing a promising future due to the high storage efficiency, low emissions, and wide applications. This paper presents a new coordination control scheme between the offshore wind farm and a hydrogen management system (HMS) for reducing the adverse impacts of wind variability. In the proposed scheme, the HMS is situated onshore to provide medium- to long-term energy balancing service. A supercapacitor bank is supplemented to the system for providing the short-term transient compensation. System configuration and control strategies are also presented. Simulation tests were conducted to verify the feasibility and effectiveness of the proposed control. Test results indicate that the proposed control makes the wind farm be more flexible to satisfy the grid operation.