Jia Zhang

Dr. Jia Zhang


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2021 in Physics of Plasmas
Verified
Journal Article
Closed access
PDF file
JZJia Zhang
Jia Zhang
XJXin Ji
Xin Ji
QCQi Cheng
Qi Cheng
JJJing Jia
Jing Jia
Results simulating time-resolved pulsed electron-beam emission from a triggered four-gap pseudospark device are presented. It is important for many applications to explore the mechanisms of the pulsed electron-beam current generated in the multi-gap pseudospark discharge devices. From experiments, it is known that the pulsed emitted electron pulse is principally at the beginning, characterized by a rather short part of high energetic electrons followed by a broad pulse of electrons with an average energy of half of applied voltage. These characteristics of the electron-beam current have been simulated for a four-gap pseudospark discharge device with anode voltages from 20 to 50 kV, and with Ar as working gas in a pressure range from 20 to 60 Pa. According to the results, when the pressure becomes higher than a specific threshold, the two peaks are found to merge together. When the anode voltage is 20 kV, the pressure threshold is about 30 Pa. When the anode voltage is above 30 kV, the pressure threshold is about 40 Pa. It is observed that the energy spectrum of the high-energetic part of pulsed electron-beam contains a large peak corresponding to several keVs in the initial stage, and then it shifts toward lower energies. From the simulation, this specific characteristic is verified that the time duration of the high-energetic part of the pulsed electron-beam current grows with increasing anode voltage and decreasing pressure.

2 December 2022 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
CZChengwei Zhao
Chengwei Zhao
XLXiaoping Li
Xiaoping Li
YLYanming Liu
Yanming Liu
DLDonglin Liu
Donglin Liu
CSChao Sun
Chao Sun
WBWeimin Bao
Weimin Bao
In the diagnosis of plasma microwave transmission, when the plasma size is large and the electron density is high, the microwave will cause a phase period ambiguity problem. In order to solve the phase ambiguity, a novel method of using the phase shift group delay (PSGD) to recover the true phase shift is proposed. The PSGD method is used to recover the simulated phase shift and diagnose the plasma. The diagnostic accuracy is all greater than 91%, which verifies the method. And the new method is used to diagnose the real inductively coupled plasma with high precision. Through analysis, the method of group delay recover phase shift is more suitable for stable plasma or slow-varying plasma.

14 September 2023 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
CLCheng Luo
Cheng Luo
JZJia Zhang
Jia Zhang
YLYanming Liu
Yanming Liu
QWQiang Wei
Qiang Wei
XLXin Liu
Xin Liu
MLMengjiao Lin
Mengjiao Lin
A plasma sheath will be generated around the hypersonic vehicle during reentry, and a large number of electrons in the plasma sheath will seriously affect the communication of the vehicle. In order to reduce the electron density of plasma sheath, based on the air dissociation and ionization model including seven components and 18 chemical reactions, the reduction effect of aerodynamic actuation on the electron density of plasma sheath is studied by numerical simulation. First, the plasma flow field around RAMC-II vehicle at an altitude of 30 km is calculated. The calculated electron density distribution is basically consistent with flight test and NASA data. On this basis, the effects of aerodynamic actuation with different number and pressure on the electron density of the plasma sheath is studied. The simulation results show that aerodynamic actuation hinders the incoming flow from flowing downstream, reduces the velocity and temperature of the downstream flow field, ultimately resulting in a significant attenuation of the downstream electron density. The attenuation of the electron density caused by double aerodynamic actuation is significantly greater than that caused by single actuation, with a maximum attenuation amplitude of about 75 $\%$ . Finally, the propagation characteristic of electromagnetic (EM) wave of 5.8 GHz ( $C$ -band) frequency in the plasma sheath is studied by simulation. The results indicate that after the sheath is disturbed by aerodynamic actuation, the signal loss of electromagnetic wave is significantly reduced, with a maximum reduction of about 20 dB.

26 May 2021 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
WDWeifeng Deng
Weifeng Deng
YLYanming Liu
Yanming Liu
JZJia Zhang
Jia Zhang
MYmin yang
min yang
WOWenchong Ouyang
Wenchong Ouyang
The purpose of this article is to study the influence of different powers, pressures, frequencies, and gases on the electron density distribution in special structures. A simulation model is established, and the electronic density in a special capacitance coupled plasma (CCP) device is calculated over the power range of 0-10 kW, pressure range of 0-50 Pa, and frequency range of 13.56-300 MHz. The results show that the power is a logarithmic function of the electron density in helium and argon plasmas, and the peak value for the electron density occurs in the diffusion region. At a certain power, collisions between particles increase with increasing pressure, which leads to an increase in electron density. However, the high electron density region in the helium plasma is concentrated near the electrode, while the high density region in the argon plasma moves from the center of the device to the electrode with increasing gas pressure. At the same time, the increase in the power frequency increases the ionization rate, and energy is transferred to the electrons, which increases the electron density. However, the rate of increase in the electron density decreases with increasing power frequency at the same voltage and pressure. With increasing power frequency, the 2-D electron density distribution in the argon and helium plasmas is found to vary in a similar way to that found for increasing pressure.

1 May 2023 in Journal of Instrumentation
Verified
Journal Article
Closed access
PDF file
WDWeifeng Deng
Weifeng Deng
YLYanming Liu
Yanming Liu
RLRui Li
Rui Li
JZJia Zhang
Jia Zhang
XLXiaoping Li
Xiaoping Li
WBWeimin Bao
Weimin Bao
In this paper, a single probe (SP) has been designed for study plasma parameters of High enthalpy ICP-heated wind tunnel. It is found that the electron temperature in the core region is about 2.4 eV and that in the edge region is about 3–4 eV. At the maximum power of the High Enthalpy ICP-heated wind tunnel, the electron density reach 4.34 × 1013 cm-3. Meanwhile, the radial electron density distribution of SP is numerically integrated to calculate the line integral density, which is compared with the line integral density measured by 890 GHz HCN laser interferometer. The results show that the probe diagnosis results have the same trend as the laser diagnosis results. The line integral electron density measured by SP is 0.8 times higher than that measured by the HCN interferometer.

1 March 2022 in Physics of Plasmas
Verified
Journal Article
Closed access
PDF file
WDWeifeng Deng
Weifeng Deng
YLYanming Liu
Yanming Liu
JZJia Zhang
Jia Zhang
XLXiaoping Li
Xiaoping Li
DLDonglin Liu
Donglin Liu
WBWeimin Bao
Weimin Bao
This paper explains the physical behavior of the electron density of high-power and large-volume plasma wind tunnel using a single channel hydrogen cyanide (HCN) laser interferometer. Based on the characteristics of inductively coupled plasma (ICP)-heated wind tunnel, the temperature and pressure distribution of the ICP-heated wind tunnel are obtained from numerical simulations, during which the influence of neutral particles is considered to calculate the accurate electron density. The typical electron density order of ICP-heated wind tunnel is 1018m−3 . We discovered that there is a positive correlation between the electron density of argon plasma jet and mass flow rate, while that of air plasma jet decreases slightly. We also found that the peak of electron density appears when the argon is switched to air. Within the voltage range of 6–10 kV, the electron density of argon and air plasma increases slowly. However, when the voltage increases from 10 to 12 kV, the electron density of air plasma increases sharply with the mass flow rate of 15 g/s. Finally, the electron density of argon plasma is much higher than that of air plasma at the same mass flow rate and voltage.