David Ryan

Dr. David Ryan


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

21 February 2022 in Nanomaterials
Verified
Journal Article
Open access
PDF file
YZYipei Zhang
Yipei Zhang
ABAnila Bello
Anila Bello
DRDavid Ryan
David Ryan
PDPhilip Demokritou
Philip Demokritou
DBDhimiter Bello
Dhimiter Bello
Inhalation exposures to nanoparticles (NPs) from printers and photocopiers have been associated with upper airway and systemic inflammation, increased blood pressure, and cases of autoimmune and respiratory disorders. In this study we investigate oxidative stress induced by exposures to copier-emitted nanoparticles using a panel of urinary oxidative stress (OS) biomarkers representing DNA damage (8-hydroxydeoxyguanosine, 8-OHdG; 8-hydroxyguanosine, 8-OHG; 5-hydroxymethyl uracil 5-OHMeU), lipid peroxidation (8-isoprostane; 4-hydroxynonenal, HNE), and protein oxidation biomarkers (o-tyrosine, 3-chlorotyrosine, and 3-nitrotyrosine) under conditions of acute (single 6 h exposure, 9 volunteers, 110 urine samples) and chronic exposures (6 workers, 11 controls, 81 urine samples). Urinary biomarkers were quantified with liquid chromatography–tandem mass spectrometry after solid phase extraction sample cleanup. 8-OHdG, 8-OHG, 8-isoprostane, and HNE were significantly elevated in both the acute and chronic exposure study participants relative to the controls. In the acute exposure study, the geometric mean ratios post-/pre-exposure were 1.42, 1.10, 2.0, and 2.25, respectively. Urinary 8-OHG and HNE increased with time to at least 36 h post-exposure (post-/pre-exposure GM ratios increased to 3.94 and 2.33, respectively), suggesting slower generation and/or urinary excretion kinetics for these biomarkers. In chronically exposed operators, the GM ratios of urinary biomarkers relative to controls ranged from 1.52 to 2.94, depending on the biomarker. O-Tyrosine and 5-OHMeU biomarkers were not significantly different from the controls. 3-chlorotyrosine and 3-nitrotyrosine were not detected in the urine samples. We conclude that NPs from photocopiers induce systemic oxidative stress by damaging DNA, RNA, and lipids. Urinary levels of 8-OHdG, 8-OHG, HNE, and 8-isoprostane were orders of magnitude higher than in nanocomposite processing workers, comparable to nano titanium dioxide and fiberglass manufacturing workers, but much lower than in shipyard welding and carbon nanotube synthesis workers. Biomarkers 8-OHdG, 8-OHG, 8-isoprostane, and HNE appear to be more sensitive and robust urinary biomarkers for monitoring oxidative stress to NPs from photocopiers.

19 September 2018
Verified
Book Chapter
Open access
PDF file
BZbingqi zhu
bingqi zhu
DRDavid Ryan
David Ryan
The environmental problem of uranium waste has attracted global attention, and the investigation of its migration behavior in the environment has become an important topic. Uranyl ion is the most distributed form of uranium in water, and its mobility is highly affected by dissolved organic matter (DOM) due to its complexation in aquatic systems. In this study, DOMs in a variety of water samples from the Merrimack Valley of Massachusetts in the USA were studied using fluorescence excitation-emission matrix (EEM) techniques and regional integration analysis (RIA) data treatment method. RIA divided an EEM of DOM into five regions according to its fluorescence features and categorized them as humic-acid-like, fulvic-acid-like and amino-acid-like. Fluorescence quenching techniques were used to study the complexation properties of DOM with uranyl ion in aquatic systems at pH 3.5. Intense peaks in regions III and V were found to be quenched during the titration by uranyl ion. Results obtained showed that the stability constants (log K) were 4.01–4.19 and 3.83–3.97 for regions III and V, respectively. This study provides an easy, nondestructible and effective approach for studying the complexation of uranyl ion with DOM by applying the RIA method with fluorescence quenching.