Piergiorgio Tozzi

Prof. Dr. Piergiorgio Tozzi

Department of Cardiac Surgery, Centre Hospitalier Universitaire Vaudois CHUV, University of Lausanne, Lausanne, Switzerland
orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 October 2020 in European Journal of Cardio-Thoracic Surgery
Verified
Journal Article
Open access
PDF file
PTPiergiorgio Tozzi
Piergiorgio Tozzi
ZGZiyad GUNGA
Ziyad GUNGA
LNLars Niclauss
Lars Niclauss
DDDominique Delay
Dominique Delay
ARAurelian Roumy
Aurelian Roumy
MKMatthias Kirsch
Matthias Kirsch
Current guidelines recommend prophylactic replacement of the ascending aorta at an aneurysmal diameter of >55 mm to prevent acute Type A aortic dissection (TAAD) in non-Marfan patients. Several publications have challenged this threshold, suggesting that surgery should be performed in smaller aneurysms to prevent this devastating disease. We reviewed our experience with measuring aortic size at the time of TAAD to validate the existing recommendation for prophylactic ascending aorta replacement. All patients who had been admitted for TAAD to our emergency department from 2014 to 2019 and underwent ascending aorta replacement were included. Marfan patients were excluded. The maximum diameter of the dissected aorta was measured preoperatively using CT scan. We estimated the aortic diameter at the time of dissection to be 7 mm smaller than the measured maximum diameter of the dissected aorta (modelled pre-dissection diameter). Overall, 102 patients were included. Of these, 67 were male (65.6%) and 35 were female (34.4%), and the cohort’s mean age was 65 ± 12.1 years. In addition, 66% were treated for arterial hypertension. The mean maximum modelled pre-dissection diameter was 39.6 ± 4.8 mm: 39.1 ± 5.1 mm in men and 40.7 ± 2.8 mm in women (P = 0.1). The cumulative 30-day mortality rate was 19.6% (20/102). TAAD occurred at a modelled aortic diameter below 45 mm in 87.7% of our patients. Therefore, the current aortic diameter threshold of 55 mm excludes ∼99% of patients with TAAD from prophylactic replacement of the ascending aorta. The maximum diameter of the ascending aorta warrants reappraisal and this parameter should be a distinct part of a personalized decision-making process that also takes into account age, gender and body surface area to establish the surgical indication for preventive aorta replacement aimed to improve the survival benefit of this procedure.

9 August 2021 in Interactive CardioVascular and Thoracic Surgery
Verified
Journal Article
Open access
PDF file
LCLouis-Emmanuel Chriqui
Louis-Emmanuel Chriqui
PMPierre Monney
Pierre Monney
MKMatthias Kirsch
Matthias Kirsch
PTPiergiorgio Tozzi
Piergiorgio Tozzi
: OBJECTIVES: Between 10% and 40% of patients who receive a left ventricular assistance device (LVAD) suffer from right ventricular failure (RVF) shortly after the device is implanted. Patients with post-LVAD RVF tend to have poor outcomes. Only a few predictive factors concerning the right ventricle (RV) have been investigated. Our goal was to search for non-invasive variables that correlate with RV function, focusing on echocardiographic parameters of the RV.METHODS: We selected 3 parameters: tricuspid annular plane systolic excursion, right ventricular fractional area change and right ventricular global longitudinal strain. We searched the literature and pooled relevant studies in a meta-analysis. Finally, we performed a statistical analysis to confirm whether each parameter was a reliable predictor of RVF after LVAD implantation.RESULTS: We retained 19 articles involving a total of 1561 patients. We found a pooled standardized mean deviation of −0.13 cm for the tricuspid annular plane systolic excursion, with the lower and upper tails of −0.21 and −0.04 cm, respectively. Concerning the right ventricular fractional area change, the averaged standardized mean deviation was equal to −2.61%, with the lower and upper extremities of −4.12% and −1.09%, respectively. Finally, regarding the global longitudinal strain, the standardized mean deviation was equal to −2.06% with an uncertainty value between −3.23% and −0.88%.CONCLUSIONS: The tricuspid annular plane systolic excursion could be a reliable parameter in RVF prediction. The right ventricular fractional area change and global longitudinal strain are likely to be stronger predictors of RVF after LVAD implantation. Prospective studies should be carried out to confirm this observation.

6 September 2017 in Journal of Cardiothoracic Surgery
Verified
Journal Article
Open access
PDF file
Enrico FerrariEnrico Ferrari
Enrico Ferrari
EEEric Eeckhout
Eric Eeckhout
SKSanjiv Keller
Sanjiv Keller
OMOlivier Muller
Olivier Muller
PTPiergiorgio Tozzi
Piergiorgio Tozzi
LSLudwig Karl von Segesser
Ludwig Karl von Segesser
Transcatheter aortic valve implantation is indicated in high-risk patients with aortic stenosis. We compared the clinical outcome of 180 consecutive patients who underwent transapical (TA) and transfemoral (TF) procedures in a single centre. Ninety consecutive TA (TA-group) and 90 consecutive TF (TF-group) were performed from 2009 to 2014. Clinical variables were prospectively collected and retrospectively analysed for hospital outcomes and to identify risk factors for hospital mortality, vascular complications and stroke. Mean age was 80 ± 8.5 and 83 ± 8.4 years, in the TA and TF-group, respectively. TA-group presented higher prevalence of comorbidities: more vascular disease (79% vs 22%, p < 0.001), chronic pulmonary disease (32% vs 10%, p < 0.001), previous vascular surgery (14% vs 4%, p = 0.039), coronary disease (60% vs 40%, p = 0.007), and previous cardiac surgery (28% vs 17%, p = 0.073). Logistic Euroscore was 36 ± 15% in the TA-group and 25 ± 14% in the TF-group (p < 0.001), but hospital mortality was similar (TA:9%, TF:10%, p = 0.799). Access-related vascular complications occurred more often in transfemoral patients (TA:3%, TF:11%, p = 0.081) while major bleeding (TA:3%, TF:4%, p = 1) and stroke (TA:2%, TF:3%, p = 1) were equally distributed. Postoperative renal failure and dialysis were associated with impaired neurological outcome (p = 0.035 and p = 0.020, respectively). Mild to severe paravalvular leak was more prevalent in transfemoral patients (TA:5%, TF:25%, p < 0.001). In our experience, the TA and TF-group presented different risk profiles but mortality rate and adverse neurological outcome had a similar incidence. The transfemoral approach carried more vascular complications and paravalvular leaks but last-generation devices will improve this outcome.

4 July 2023 in Infection
Verified
Journal Article
Open access
PDF file
Matthaios Papadimitriou-OlivgerisMatthaios Papadimitriou-Olivgeris
Matthaios Papadimitriou-Olivgeris
BGBenoit Guery
Benoit Guery
NINicoleta Ianculescu
Nicoleta Ianculescu
DADenise Auberson
Denise Auberson
PTPiergiorgio Tozzi
Piergiorgio Tozzi
PMPierre Monney
Pierre Monney
Purpose: Embolic events (EEs) are a common complication of left-side infective endocarditis (IE). The aim of the present study was to identify risk factors for the occurrence of EEs before or after antibiotic treatment instauration among patients with definite or possible IE. Methods: This retro-prospective study was conducted at the Lausanne University Hospital, Lausanne, Switzerland, from January 2014 to June 2022. EEs and IE were defined according to modified Duke criteria. Results: A total of 441 left-side IE episodes were included (334: 76% were definite and 107; 24% possible IE). EE were diagnosed in 260 (59%) episodes; in 190 (43%) before antibiotic treatment initiation and 148 (34%) after. Central nervous system (184; 42%) was the most common site of EE. Multivariable analysis identified S. aureus (P 0.022), immunological phenomena (P < 0.001), sepsis (P 0.027), vegetation size ≥ 10 mm (P 0.003) and intracardiac abscess (P 0.022) as predictors of EEs before antibiotic treatment initiation. For EEs after antibiotic treatment initiation, multivariable analysis revealed vegetation size ≥ 10 mm (P < 0.001), intracardiac abscess (P 0.035) and prior EE (P 0.042), as independent predictors of EEs, while valve surgery (P < 0.001) was associated with lower risk for EEs. Conclusions: We reported a high percentage of EEs among patients with left-side IE; vegetation size, intracardiac abscess, S. aureus and sepsis were independently associated with the occurrence of EEs. In addition to antibiotic treatment, early surgery led to further decrease in EEs incidence.

8 July 2016 in BMC Infectious Diseases
Verified
Journal Article
Open access
PDF file
S(Swiss Transplant Cohort Study (STCS)
Swiss Transplant Cohort Study (STCS)
DHDelphine Héquet
Delphine Héquet
GKGeorg Kralidis
Georg Kralidis
TCThierry Pierre Carrel
Thierry Pierre Carrel
ACAlexia Cusini
Alexia Cusini
OMOriol Manuel
Oriol Manuel
Ventricular assist devices (VAD) are valuable options for patients with heart failure awaiting cardiac transplantation. We assessed the impact of pre-transplant VAD implantation on the incidence of post-transplant infections in a nationwide cohort of heart transplant recipients. Heart transplant recipients included in the Swiss Transplant Cohort Study between May 2008 and December 2012 were analyzed. Cumulative incidence curves were used to calculate the incidence of bacterial or Candida infections (primary endpoint) and of other infections (secondary endpoint) after transplant. Cox regression models treating death as a competing risk were used to identify risk factors for the development of infection after transplant. Overall, 119 patients were included in the study, 35 with a VAD and 84 without VAD. Cumulative incidences of post-transplant bacterial or Candida infections were 37.7 % in VAD patients and 40.4 % in non-VAD patients. In multivariate analysis, the use of cotrimoxazole prophylaxis was the only variable associated with bacterial/Candida infections after transplant (HR 0.29 [95 % CI 0.15-0.57], p < 0.001), but presence of a VAD was not (HR 0.94, [95 % CI 0.38-2.32], p = 0.89, for continuous-flow devices, and HR 0.45 [0.15 – 1.34], p = 0.15, for other devices). Risk for post-transplant viral and all fungal infections was not increased in patients with VAD. One-year survival was 82.9 % (29/35) in the VAD group and 82.1 % (69/84) in the non-VAD group. All 6 patients in the VAD group that died after transplant had a history of pre-transplant VAD infection. In this nationwide cohort of heart transplant recipients, the presence of VAD at the time of transplant had no influence on the development of post-transplant infections.

1 December 2009 in European Journal of Cardio-Thoracic Surgery
Verified
Journal Article
Open access
PDF file
BPBertrand R.M. Perrin
Bertrand R.M. Perrin
MDMichel Dupeux
Michel Dupeux
PTPiergiorgio Tozzi
Piergiorgio Tozzi
DDDominique Delay
Dominique Delay
PGPhilippe Gersbach
Philippe Gersbach
LSLudwig K. von Segesser
Ludwig K. von Segesser
Objective: The aim of this study is to create a standard test to approve the efficacy of a surgical sealant. An industrial test, the bulge-and-blister test, which is very convenient for measuring adhesion energy, is applied to the surgical field to quantify adhesion of bioadhesives. Methods: Samples were composed of two circular layers of equine pericardium glued by the surgical sealant studied. The sample was fixed to a support with an industrial glue. The support and the bottom layer were perforated in the centre to allow injection of pressurised water. Water was progressively introduced through the hole in the support and the bottom layer to create a blister with constant radius, increasing height and internal pressure during this first step. At a critical pressure, delamination started, the radius and height of the blister increased and the pressure decreased. At this point, the adhesion energy could be determined. The experimental parameters were measured with a pressure sensor and an optical profilometry device for deflection. Results: Adhesion testing was carried out in eight paired equine pericardium samples bonded with a Dermabond® cyanoacrylate glue. The average value of the practical adhesion energy is 2.3 J m−2 with a standard deviation of 1.5 J m−2. Conclusion: Application of the bulge-and-blister test to the surgical field was achieved and allowed a quantification of adhesion of a surgical glue. Such information is essential to compare the different surgical glues presently available. The study of the impact of bonding conditions such as pressure, hygrometry or setting conditions will provide a better understanding of the characteristics of adhesion in the surgical field.