Giuseppe Rizzelli Martella

Prof. Dr. Giuseppe Rizzelli Martella

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 June 2021 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
GRGiuseppe Rizzelli
Giuseppe Rizzelli
ANAntonino Nespola
Antonino Nespola
SSStefano Straullu
Stefano Straullu
FFFabrizio Forghieri
Fabrizio Forghieri
RGRoberto Gaudino
Roberto Gaudino
International standardization bodies (IEEE and ITU-T) working on the evolution of transmission technologies are still considering traditional direct detection solutions for the most relevant short-reach optical link applications, that are Passive Optical Networks (PON) and intra-data center interconnects. Anyway, future jumps towards even higher bit rates per wavelength will require a complete paradigm shift, moving towards coherent technologies. In this paper, we thus study both analytically and experimentally the scaling laws of unamplified coherent transmission in the short-reach communications ecosystems. We believe that, given the extremely tight techno-economic constraints, such a revolutionary transition towards coherent in short-reach first requires a very detailed study of its intrinsic capabilities in largely extending the limitation currently imposed by direct detection systems. To this end, this paper focuses on the ultimate physical layer limitations of unamplified coherent systems in terms of bit rate and power budget. The main parameters of our performance estimation model are extracted through fitting with a set of experimental characterizations and later used as the starting point of a scaling laws study regarding local oscillator power, modulator-induced attenuation, bit rate, and maximum achievable power budget. The analytically predicted performance is then verified through transmission experiments, including a demonstration on a 37-km installed metropolitan dark fiber in the city of Turin. Our findings show that coherent detection without optical pre-amplification and using PM-QPSK can tolerate optical power budget (OPB) well above, for instance, the 29 dB imposed by the current PON standards even at extremely high raw bit rates up to 800 $Gbps$ . PM-16QAM, on the other hand, can provide up to 190 $Gbps$ at 29 dB OPB only if combined with soft FEC algorithms. Even higher bit rates are also shown for the less demanding power budget needed in intra-data centers links.

14 January 2021 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
ILIlaria Di Luch
Ilaria Di Luch
Pierpaolo BoffiPierpaolo Boffi
Pierpaolo Boffi
MFMaddalena Ferrario
Maddalena Ferrario
GRGiuseppe Rizzelli
Giuseppe Rizzelli
RGRoberto Gaudino
Roberto Gaudino
Mario MartinelliMario Martinelli
Mario Martinelli
The optical fiber deployed in the metropolitan infrastructure carrying high-speed WDM traffic data is used also for network surveillance, identifying and localizing the onset of vibrations and dynamic stress events, potentially dangerous for the integrity of the fiber telecom asset. A coherent approach is adopted in a counter-propagating interferometer to develop a sensing system exploiting the ring layout of the metro net- work. With respect to usual dual Mach-Zehnder interferometric sensors, where typically the reference arm is kept isolated, in our arrangement we use as reference arm a fiber inside the same deployed cable, minimizing the impact of the city strong environmental noise. Preliminary assessments of the proposed sensing solution have been experimented in a metro ring of 32 km standard single-mode fiber deployed in the city of Turin, Italy, devoted to telecom applications. The sensor is demonstrated to operate preserving the coexistence with the high-speed WDM telecom traffic. With respect to complex and expensive sensing solutions based on pulsed phase-OTDR techniques, in the present case continuous-wave counter-propagating optical signals are exploited and the spatial resolution in dynamic event localization depends only on the receiver sampling rate: in our implementation, by adopting off-the shelf low-cost commercial 20MS/s sampling boards, 10-meter spatial resolution is experimentally achieved. The proposed sensing solution provides significant added value to the deployed metro fiber infrastructure and the same interferometric approach based on the counter-propagating layout can be easily exploited in metro networks even in case of presence of optical nodes equipped with reconfigurable optical add-drop multiplexers useful for WDM traffic routing.

8 December 2022 in Optics Express
Verified
Journal Article
Closed access
AHAbir Hraghi
Abir Hraghi
GRGiuseppe Rizzelli
Giuseppe Rizzelli
APAnnachiara Pagano
Annachiara Pagano
VFValter Ferrero
Valter Ferrero
RGRoberto Gaudino
Roberto Gaudino
Passive optical network (PON) based on coherent detection has attracted a great deal of attention in recent years as a future solution for 100+ Gbps per wavelength. Particularly for 200G-PON, one of the most attractive options would be to switch to QAM transmission and coherent detection, due to its well know advantages compared to the Direct-Detection approaches used so far in PON. However, coherent technology, extensively used in core networks, has costs that are still perceived as too high for the access ecosystem. In order to perform cost reduction, some groups have studied the option of coherent polarization-independent (PI) detection, since it halves the number of optoelectronic components in the receiver front end. In this paper, we thus present a detailed simulative and experimental investigation of polarization-independent receivers to achieve 200 Gbps transmission in C band using the Alamouti polarization time block coding (PTBC). Our goal is to show what would be the system requirements in terms of optoelectronic bandwidths, laser phase noise and ultimate power budget limitations. We study two different modulation formats: quadrature phase-shift keying (QPSK) and 16 quadrature amplitude modulation (16QAM). We also compare heterodyne and homodyne/intradyne solutions through simulations. As a summarizing result, we experimentally show that 200G PON based on 50 Gbaud-16QAM single-polarization Alamouti coded signals would be possible with today state-of-the-art coherent technologies, demonstrating an Optical Distribution Network loss above 33 dB with 25 km fiber length, a very promising result that is compliant with the PON power budget E1 class.

23 January 2025 in Journal of Optical Communications and Networking
Verified
Journal Article
Closed access
SPSaverio Pellegrini
Saverio Pellegrini
LMLeonardo Minelli
Leonardo Minelli
LALorenzo Andrenacci
Lorenzo Andrenacci
GRGiuseppe Rizzelli
Giuseppe Rizzelli
DPDario Pilori
Dario Pilori
RGRoberto Gaudino
Roberto Gaudino
Given the ubiquity of optical fiber networks in both terrestrial and submarine environments, leveraging these facilities for sensing anomalous conditions alongside telecommunications can provide significant added value. In this context, distributed acoustic sensing (DAS) systems have been widely employed and discussed due to their sensitivity and ability to locate events. However, integrating them within existing networks is complex and expensive. On the other hand, the received state of polarization (SOP) is also sensitive to external factors, and it can be used for sensing: in this case, no extra hardware would be required since the SOP is already estimated in coherent receivers for data demodulation. The sensing information is provided “for free” by the already installed hardware, potentially requiring only a software upgrade. In this work, we analyze the feasibility of using polarization-based sensing to detect anomalous conditions in metropolitan environments. A polarimeter was used to evaluate SOP noise induced by urban factors, while a commercial coherent transceiver was employed to assess SOP estimation noise. We propose two algorithms for processing polarization data: a time-based method called SOP angular speed (SOPAS) and an adaptive, frequency-based approach named SOP-power spectral density gap (SOP-PSDG). These algorithms were compared by processing Stokes vector samples from the polarimeter when different sinusoidal vibrations are applied to the fiber through a mechanical shaker. Results demonstrate that a sampling rate of just a few tens of Hz is sufficient to effectively identify various hazardous conditions, with SOP-PSDG consistently outperforming SOPAS. Additionally, preliminary findings on the performances of these algorithms using SOP samples from a commercial coherent receiver are discussed.

19 November 2021 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
PTPablo Torres-Ferrera
Pablo Torres-Ferrera
GRGiuseppe Rizzelli
Giuseppe Rizzelli
HWhaoyi wang
haoyi wang
VFValter Ferrero
Valter Ferrero
RGRoberto Gaudino
Roberto Gaudino
Passive Optical Networks (PON), able to operate at 50 Gbps per wavelength (), are under development and standardization, based on intensity-modulation (IM) and direct-detection (DD) systems. The next step in PON evolution will be driven by 5G/6G fronthauling capacity demands, and will require the development of 100 Gbps/ (and beyond) systems, which poses big challenges if maintaining the DD-format. In this contribution, we analyze a 100 Gbps/ PON architecture able to preserve the IM-DD approach at the Optical Network Unit (ONU), placing the complexity at the Optical Line Terminal (OLT), thanks to Digital Signal Processing (DSP). We experimentally demonstrate a 100 Gbps/ transmission using this architecture in the downstream (DS) direction. Chromatic dispersion digital pre-compensation (CD-DPC) in combination with an IQ Mach-Zehnder Modulator (IQ-MZM) is used at the transmitter (TX). Keeping the ONU DSP as simple as possible, as compared with current DSP proposals for 50 Gbps/ PON, is another main goal of this work. Adaptive equalization (AEQ) is used to correct for linear impairments, in addition to digital non-linear correction (NLC) at the receiver (RX). We compare two NLC approaches: a full Volterra Non-Linear Equalizer (VNLE) and a simpler NLC technique based on a square-root like function (SQRT). Operation over standard single-mode fiber (SMF) in C-band, achieving reaches from 0 km to 100 km and Optical Path Loss (OPL) values higher than 29 dB, are shown. The analyzed proposal is directly applicable to Terabit-capable wavelength division multiplexing (WDM)-PON, and can be extended to very high-speed Time Division Multiplexing (TDM)-PON and TWDM-PON, with some modifications discussed here.

4 September 2020 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
PTPablo Torres-Ferrera
Pablo Torres-Ferrera
GRGiuseppe Rizzelli
Giuseppe Rizzelli
VFValter Ferrero
Valter Ferrero
RGRoberto Gaudino
Roberto Gaudino
We experimentally demonstrate a single-wavelength 100 Gbps downstream PON transmission aided by chromatic dispersion digital pre-compensation (CD-DPC) using simple Digital Signal Processing (DSP) Finite Impulse Response (FIR) filters in combination with an IQ Mach-Zehnder Modulator (IQ-MZM) at the transmitter side and direct-detection receiver at the Optical Network Unit (ONU). A reach of 50 km over standard single-mode fiber in C-band and an Optical Distribution Network (ODN) loss of 28.5 dB are achieved. Transmission of 50 and 125 Gbps over 50 km of fiber is also tested, achieving 32 dB and 24 dB of ODN loss, respectively. The complexity of the filters, the optimization of the main design parameters and the tolerance of the CD-DPC to the uncertainty of the exact accumulated link dispersion are analyzed in detail.