M. Selles

Mr. M. Selles

University of Twente, Enschede, the Netherlands
+1
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 December 2023 in European Journal of Radiology
Verified
Journal Article
Closed access
M. SellesM. Selles
M. Selles
JOJochen A.C. van Osch
Jochen A.C. van Osch
MMMario Maas
Mario Maas
MBMartijn F. Boomsma
Martijn F. Boomsma
RWRuud H.H. Wellenberg
Ruud H.H. Wellenberg

20 April 2023 in European Journal of Radiology
Verified
Journal Article
Closed access
M. SellesM. Selles
M. Selles
DSDerk J. Slotman
Derk J. Slotman
JOJochen A.C. van Osch
Jochen A.C. van Osch
INIngrid M. Nijholt
Ingrid M. Nijholt
RWRuud.H.H. Wellenberg
Ruud.H.H. Wellenberg
MBMartijn. F. Boomsma
Martijn. F. Boomsma

24 November 2021 in Insights into Imaging
Verified
Journal Article
Open access
PDF file
M. SellesM. Selles
M. Selles
VSVera H. Stuivenberg
Vera H. Stuivenberg
RWRuud H. H. Wellenberg
Ruud H. H. Wellenberg
LRLoes van de Riet
Loes van de Riet
INIngrid M. Nijholt
Ingrid M. Nijholt
MBMartijn F. Boomsma
Martijn F. Boomsma
Objective: To quantify metal artifact reduction using 130 keV virtual monochromatic imaging (VMI) with and without orthopedic metal artifact reduction (O-MAR) in total hip arthroplasty. Methods: Conventional polychromatic images and 130 keV VMI of a phantom with pellets representing bone with unilateral or bilateral prostheses were reconstructed with and without O-MAR on a dual-layer CT. Pellets were categorized as unaffected, mildly affected and severely affected. Results: When 130 keV VMI with O-MAR was compared to conventional imaging with O-MAR, a relative metal artifact reduction in CT values, contrast-to-noise (CNR), signal-to-noise (SNR) and noise in mildly affected pellets (67%, 74%, 48%, 68%, respectively; p < 0.05) was observed but no significant relative metal artifact reduction in severely affected pellets. Comparison between 130 keV VMI without O-MAR and conventional imaging with O-MAR showed relative metal artifact reduction in CT values, CNR, SNR and noise in mildly affected pellets (92%, 72%, 38%, 51%, respectively; p < 0.05) but negative relative metal artifact reduction in CT values and noise in severely affected pellets (− 331% and -223%, respectively; p < 0.05), indicating aggravation of metal artifacts. Conclusion: Overall, VMI of 130 keV with O-MAR provided the strongest metal artifact reduction.

14 March 2024 in European Radiology Experimental
Verified
Journal Article
Open access
PDF file
M. SellesM. Selles
M. Selles
RWRuud H. H. Wellenberg
Ruud H. H. Wellenberg
DSDerk J. Slotman
Derk J. Slotman
INIngrid M. Nijholt
Ingrid M. Nijholt
JOJochen A. C. van Osch
Jochen A. C. van Osch
MBMartijn F. Boomsma
Martijn F. Boomsma
Background: To compare image quality, metal artifacts, and diagnostic confidence of conventional computed tomography (CT) images of unilateral total hip arthroplasty patients (THA) with deep learning-based metal artifact reduction (DL-MAR) to conventional CT and 130-keV monoenergetic images with and without orthopedic metal artifact reduction (O-MAR). Methods: Conventional CT and 130-keV monoenergetic images with and without O-MAR and DL-MAR images of 28 unilateral THA patients were reconstructed. Image quality, metal artifacts, and diagnostic confidence in bone, pelvic organs, and soft tissue adjacent to the prosthesis were jointly scored by two experienced musculoskeletal radiologists. Contrast-to-noise ratios (CNR) between bladder and fat and muscle and fat were measured. Wilcoxon signed-rank tests with Holm-Bonferroni correction were used. Results: Significantly higher image quality, higher diagnostic confidence, and less severe metal artifacts were observed on DL-MAR and images with O-MAR compared to images without O-MAR (p < 0.001 for all comparisons). Higher image quality, higher diagnostic confidence for bone and soft tissue adjacent to the prosthesis, and less severe metal artifacts were observed on DL-MAR when compared to conventional images and 130-keV monoenergetic images with O-MAR (p ≤ 0.014). CNRs were higher for DL-MAR and images with O-MAR compared to images without O-MAR (p < 0.001). Higher CNRs were observed on DL-MAR images compared to conventional images and 130-keV monoenergetic images with O-MAR (p ≤ 0.010). Conclusions: DL-MAR showed higher image quality, diagnostic confidence, and superior metal artifact reduction compared to conventional CT images and 130-keV monoenergetic images with and without O-MAR in unilateral THA patients. Relevance statement: DL-MAR resulted into improved image quality, stronger reduction of metal artifacts, and improved diagnostic confidence compared to conventional and virtual monoenergetic images with and without metal artifact reduction, bringing DL-based metal artifact reduction closer to clinical application. Key points: • Metal artifacts introduced by total hip arthroplasty hamper radiologic assessment on CT. • A deep-learning algorithm (DL-MAR) was compared to dual-layer CT images with O-MAR. • DL-MAR showed best image quality and diagnostic confidence. • Highest contrast-to-noise ratios were observed on the DL-MAR images. Graphical

17 January 2022 in European Journal of Radiology
Verified
Journal Article
Closed access
M. SellesM. Selles
M. Selles
JKJ.H. Korte
J.H. Korte
HBH.J. Boelhouwers
H.J. Boelhouwers
INIngrid Nijholt
Ingrid Nijholt
JOJ.A.C. van Osch
J.A.C. van Osch
MBMartijn Boomsma
Martijn Boomsma

6 December 2020 in Diagnostics
Verified
Journal Article
Open access
PDF file
OMOnno Mennes
Onno Mennes
M. SellesM. Selles
M. Selles
JNJaap J. Van Netten
Jaap J. Van Netten
JBJeff G. van Baal
Jeff G. van Baal
WSWiendelt Steenbergen
Wiendelt Steenbergen
Riemer H.J.A. SlartRiemer H.J.A. Slart
Riemer H.J.A. Slart
Foot ulcers are a severe complication of diabetes mellitus. Assessment of the vascular status of diabetic foot ulcers with Laser Speckle Contrast Imaging (LSCI) is a promising approach for diagnosis and prognosis. However, manual assessment during analysis of LSCI limits clinical applicability. Our aim was to develop and validate a fast and robust tracking algorithm for semi-automatic analysis of LSCI data. The feet of 33 participants with diabetic foot ulcers were recorded with LSCI, including at baseline, during the Post-Occlusive Reactive Hyperemia (PORH) test, and during the Buerger’s test. Different regions of interest (ROIs) were used to measure microcirculation in different areas of the foot. A tracking algorithm was developed in MATLAB to reposition the ROIs in the LSCI scans. Manual- and algorithm-tracking of all recordings were compared by calculating the Intraclass Correlation Coefficient (ICC). The algorithm was faster in comparison with the manual approach (90 s vs. 15 min). Agreement between manual- and algorithm-tracking was good to excellent during baseline (ICC = 0.896–0.984; p < 0.001), the PORH test (ICC = 0.790–0.960; p < 0.001), and the Buerger’s test (ICC = 0.851–0.978; p < 0.001), resulting in a tracking algorithm that delivers assessment of LSCI in diabetic foot ulcers with results comparable to a labor-intensive manual approach, but with a 10-fold workload reduction.