Background: Soft materials, with their compliant properties, enable conformity and safe interaction with human body. With the advance in actuation and sensing of soft materials, new paradigm in robotics called “soft robotics” emerges. Soft robotics has become a new approach in designing medical devices such as wearable robotic gloves and exoskeleton. However, application of soft robotics in surgical instrument inside human body is still in its infancy.Aims: In this paper, current application and design of soft robots specifically applied for endoscopy are reviewed.Materials & Methods: Different aspects in the implementation of soft robotics in endoscope design were reviewed. The key studies about MIS and NOTES were reviewed to establish the clinical background and extract the limitations of current endoscopic device in the last decade.Results and discussion: In this review study, the implementation of soft robotics concepts in endoscopic application, with highlights on different features of several soft endoscopes, were evaluated. The progress in different aspects of soft robotics endoscope, current state, and future perspectives were also discussed.Conclusion: Based on the survey on the structural specification, actuation, sensing, and stiffening the future soft surgical endoscopes are recommended to fulfil the following specifications: safe especially from pressure leakage, fully biocompatible materials, MR‐compatible, capable for large bending in at least two antagonistic directions, modularity, adjustable stiffness.
The finite element (FE) method has been widely used to investigate knee biomechanics. Time integration algorithms for dynamic problems in finite element analysis can be classified as either implicit or explicit. Although previously both static/dynamic implicit and dynamic explicit method have been used, a comparative study on the outcomes of both methods is of high interest for the knee modeling community. The aim of this study is to compare static, dynamic implicit and dynamic explicit solutions in analyses of the knee joint to assess the prediction of dynamic effects, potential convergence problems, the accuracy and stability of the calculations, the difference in computational time, and the influence of mass-scaling in the explicit formulation. The heel-strike phase of fast, normal and slow gait was simulated for two different body masses in a model of the native knee. Our results indicate that ignoring the dynamic effect can alter joint motion. Explicit analyses are suitable to simulate dynamic loading of the knee joint in high-speed simulations, as this method offers a substantial reduction of the computational time with a similar prediction of cartilage stresses and meniscus strains. Although mass-scaling can provide even more gain in computational time, it is not recommended for high-speed activities, in which inertial forces play a significant role.
In finite element models of the either implanted or intact human knee joint, soft tissue structures like tendons and ligaments are being incorporated, but usually skin, peripheral knee soft tissues, and the posterior capsule are ignored and assumed to be of minor influence on knee joint biomechanics. It is, however, unknown how these peripheral structures influence the biomechanical response of the knee. In this study, the aim was to assess the significance of the peripheral soft tissues and posterior capsule on the kinematics and laxities of human knee joint, based on experimental tests on three human cadaveric specimens. Despite the high inter-subject variability of the results, it was demonstrated that the target tissues have a considerable influence on posterior translational and internal and valgus rotational laxities of lax knees under flexion. Consequently, ignoring these tissues from computational models may alter the knee joint biomechanics.