Charuksha Walgama

Dr. Charuksha Walgama

ACS
+2
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 November 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Sayo FakayodeSayo Fakayode
Sayo Fakayode
Charuksha WalgamaCharuksha Walgama
Charuksha Walgama
VNVivian Fernand Narcisse
Vivian Fernand Narcisse
CGCidya Grant
Cidya Grant
Human exposure to acute and chronic levels of heavy metal ions are linked with various health issues, including reduced children’s intelligence quotients, developmental challenges, cancers, hypertension, immune system compromises, cytotoxicity, oxidative cellular damage, and neurological disorders, among other health challenges. The potential environmental HMI contaminations, the biomagnification of heavy metal ions along food chains, and the associated risk factors of heavy metal ions on public health safety are a global concern of top priority. Hence, developing low-cost analytical protocols capable of rapid, selective, sensitive, and accurate detection of heavy metal ions in environmental samples and consumable products is of global public health interest. Conventional flame atomic absorption spectroscopy, graphite furnace atomic absorption spectroscopy, atomic emission spectroscopy, inductively coupled plasma–optical emission spectroscopy, inductively coupled plasma–mass spectroscopy, X-ray diffractometry, and X-ray fluorescence have been well-developed for HMIs and trace element analysis with excellent but varying degrees of sensitivity, selectivity, and accuracy. In addition to high instrumental running and maintenance costs and specialized personnel training, these instruments are not portable, limiting their practicality for on-demand, in situ, field study, or point-of-need HMI detection. Increases in the use of electrochemical and colorimetric techniques for heavy metal ion detections arise because of portable instrumentation, high sensitivity and selectivity, cost-effectiveness, small size requirements, rapidity, and visual detection of colorimetric nanosensors that facilitate on-demand, in situ, and field heavy metal ion detections. This review highlights the new approach to low-cost, rapid, selective, sensitive, and accurate detection of heavy metal ions in ecosystems (soil, water, air) and consumable products. Specifically, the review highlights low-cost, portable, and recent advances in smartphone-operated screen-printed electrodes (SPEs), plastic chip SPES, and carbon fiber paper-based nanosensors for environmental heavy metal ion detection. In addition, the review highlights recent advances in colorimetric nanosensors for heavy metal ion detection requirements. The review provides the advantages of electrochemical and optical nanosensors over the conventional methods of HMI analyses. The review further provides in-depth coverage of the detection of arsenic (As), cadmium (Cd), chromium (Cr), copper (Cu), mercury (Hg), manganese (Mn), nickel (Ni), lead (Pb), and zinc (Zn) ions in the ecosystem, with emphasis on environmental and biological samples. In addition, the review discusses the advantages and challenges of the current electrochemical and colorimetric nanosensors protocol for heavy metal ion detection. It provides insight into the future directions in the use of the electrochemical and colorimetric nanosensors protocol for heavy metal ion detection.

10 March 2020 in ACS Sensors
Verified
Journal Article
Closed access
NPNicole E. Pollok
Nicole E. Pollok
CRCharlie Rabin
Charlie Rabin
Charuksha WalgamaCharuksha Walgama
Charuksha Walgama
LSLeilani Smith
Leilani Smith
IRIan Richards
Ian Richards
RCRichard M Crooks
Richard M Crooks

7 December 2020 in Sensors
Verified
Journal Article
Open access
PDF file
DBDavid Bwambok
David Bwambok
NSNoureen Siraj
Noureen Siraj
SMSamantha Macchi
Samantha Macchi
NLNathaniel Larm
Nathaniel Larm
GBGary A. Baker
Gary A. Baker
SFSayo Fakayode
Sayo Fakayode
Quality checks, assessments, and the assurance of food products, raw materials, and food ingredients is critically important to ensure the safeguard of foods of high quality for safety and public health. Nevertheless, quality checks, assessments, and the assurance of food products along distribution and supply chains is impacted by various challenges. For instance, the development of portable, sensitive, low-cost, and robust instrumentation that is capable of real-time, accurate, and sensitive analysis, quality checks, assessments, and the assurance of food products in the field and/or in the production line in a food manufacturing industry is a major technological and analytical challenge. Other significant challenges include analytical method development, method validation strategies, and the non-availability of reference materials and/or standards for emerging food contaminants. The simplicity, portability, non-invasive, non-destructive properties, and low-cost of NIR spectrometers, make them appealing and desirable instruments of choice for rapid quality checks, assessments and assurances of food products, raw materials, and ingredients. This review article surveys literature and examines current challenges and breakthroughs in quality checks and the assessment of a variety of food products, raw materials, and ingredients. Specifically, recent technological innovations and notable advances in quartz crystal microbalances (QCM), electroanalytical techniques, and near infrared (NIR) spectroscopic instrument development in the quality assessment of selected food products, and the analysis of food raw materials and ingredients for foodborne pathogen detection between January 2019 and July 2020 are highlighted. In addition, chemometric approaches and multivariate analyses of spectral data for NIR instrumental calibration and sample analyses for quality assessments and assurances of selected food products and electrochemical methods for foodborne pathogen detection are discussed. Moreover, this review provides insight into the future trajectory of innovative technological developments in QCM, electroanalytical techniques, NIR spectroscopy, and multivariate analyses relating to general applications for the quality assessment of food products.

7 April 2020 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
Charuksha WalgamaCharuksha Walgama
Charuksha Walgama
MNMichael P. Nguyen
Michael P. Nguyen
LBLisa M. Boatner
Lisa M. Boatner
IRIan Richards
Ian Richards
RCRichard M Crooks
Richard M Crooks
In the present article we report a new hybrid microfluidic device (hyFlow) comprising a disposable paper electrode and a three-dimensional (3D) printed plastic chip for the electrochemical detection of a magnetic bead–silver nanoparticle (MB–AgNP) bioconjugate. This hybrid device evolved due to the difficulty of incorporating micron-scale MBs into paper-only fluidic devices. Specifically, paper fluidic devices can entrap MB-containing conjugates within their cellulose or nitrocellulose fiber matrix. The hyFlow system was designed to minimize such issues and transport MB conjugates more efficiently to the electrochemical detection zone of the device. The hyFlow system retains the benefit of fluid transport by pressure-driven flow, however, no pump is required for its operation. The hyFlow device is capable of detecting either pre-formed MB–AgNP conjugates or conjugates formed in situ. The detection limit of AgNPs using this device is 12 pM, which represents just 22 AgNPs per MB.

12 April 2015 in Analytical Chemistry
Verified
Journal Article
Open access
Charuksha WalgamaCharuksha Walgama
Charuksha Walgama
RNRajasekhara Nerimetla
Rajasekhara Nerimetla
NMNicholas F. Materer
Nicholas F. Materer
DSDeniz Schildkraut
Deniz Schildkraut
JEJames F. Elman
James F. Elman
SKSadagopan Krishnan
Sadagopan Krishnan
In order to design a green microsomal bioreactor on suitably identified carbon electrodes, it is important to understand the direct electrochemical properties at the interfaces between various carbon electrode materials and human liver microsomes (HLM). The novelty of this work is on the investigation of directly adsorbed HLM on different carbon electrodes with the goal to develop a simple, rapid, and new bioanalytical platform of HLM useful for drug metabolism and inhibition assays. These novel biointerfaces are designed in this study by a one step adsorption of HLM directly onto polished basal plane pyrolytic graphite (BPG), edge plane pyrolytic graphite (EPG), glassy carbon (GC), or high-purity graphite (HPG) electrodes. The estimated direct electron transfer (ET) rate constant of HLM on the smooth GC surface was significantly greater than that of the other electrodes. On the other hand, the electroactive surface coverage and stability of microsomal films were greater on highly surface defective, rough EPG and HPG electrodes compared to the smooth GC and less defective hydrophobic BPG surfaces. The presence of significantly higher oxygen functionalities and flatness of the GC surface is attributed to favoring faster ET rates of the coated layer of thin HLM film compared to other electrodes. The cytochrome P450 (CYP)-specific bioactivity of the liver microsomal film on the catalytically superior, stable HPG surface was confirmed by monitoring the electrocatalytic conversion of testosterone to 6β-hydroxytestosterone and its inhibition by the CYP-specific ketoconazole inhibitor. The identification of optimal HPG and EPG electrodes to design biologically active interfaces with liver microsomes is suggested to have immense significance in the design of one-step, green bioreactors for stereoselective drug metabolite synthesis and drug metabolism and inhibition assays.

17 April 2017 in ACS Catalysis
Verified
Journal Article
Closed access
RNRajasekhara Nerimetla
Rajasekhara Nerimetla
Charuksha WalgamaCharuksha Walgama
Charuksha Walgama
VSVini Singh
Vini Singh
SHSteven D. Hartson
Steven D. Hartson
SKSadagopan Krishnan
Sadagopan Krishnan