This paper presents an original method, based on artificial neural networks, to reduce the torque ripple in a permanent-magnet nonsinusoidal synchronous motor. Solutions for calculating optimal currents are deduced from geometrical considerations and without a calculation step, which is generally based on the Lagrange optimization. These optimal currents are obtained from two hyperplanes. This paper takes into account the presence of harmonics in the back-EMF and the cogging torque. New control schemes are thus proposed to derive the optimal stator currents giving exactly the desired electromagnetic torque (or speed) and minimizing the ohmic losses. The torque and the speed control scheme both integrate two neural blocks, one dedicated for optimal-current calculation and the other to ensure the generation of these currents via a voltage source inverter. Simulation and experimental results from a laboratory prototype are shown to confirm the validity of the proposed neural approach.
5 January 2015 in IEEE Transactions on Industrial Electronics
Multiphase machines are well known for their fault-tolerant capability. Star-connected multiphase machines have fault tolerance in an open circuit. For an inverter switch short-circuit fault, it is possible to keep a smooth torque of a permanent magnet synchronous machine if the currents of the faulty phases are determined and their values are acceptable. This paper investigates fault-tolerant operations of an open-end five-phase drive, i.e., a multiphase machine fed with a dual-inverter supply. Inverter switch short-circuit fault is considered and handled with a simple solution. Original theoretical developments are presented. Simulation and experimental results validate the proposed strategy.
14 April 2016 in IEEE Transactions on Industrial Electronics
A novel centroid-based diagnostic method of the power switches in five-leg voltage source inverter is proposed in this paper. Using a vectorial multimachine description, a five-phase drive presenting an opened switch or an opened phase faults has typical operating characteristics in comparison to classical three-phase drives. Based on such characteristics, this paper aims to provide a simple and robust diagnostic process for switches fault regardless of the shape of the back electromotive forces (harmonic components) and the transient states due to the load variation. Original theoretical developments are presented. Experimental results are shown to validate the proposed strategy.
26 June 2017 in IEEE Journal of Emerging and Selected Topics in Power Electronics
This paper proposes a procedure that is suitable for experimental investigation of real-time open-switch and open-phase faults diagnosis of a five-leg voltage source inverter feeding a five-phase biharmonic permanent magnet synchronous machine (PMSM). The algorithm is based on the specific characteristics of multiphase machines, which allows inverter fault detection with sufficient robustness of the algorithm in the presence of fundamental and third harmonic components. First, the inverter fault effects analysis is achieved in the characteristic subspaces of the five-phase PMSM. Specificities that are interesting for the elaboration of a real-time fault detection and identification (FDI) process are highlighted. Original and particular algorithms are used for an accurate 2-D normalized fault vector extraction in a defined fault reference frame. This frame is dedicated only for FDI. To ensure the high immunity of the FDI process against transient states, a particular normalization procedure is applied. The normalized diagnostic signals are formulated from the defined frame and other variables derived from the reference and measured currents. Simulation and experimental results of open-switch and open-phase faults are provided to validate the proposed algorithm.
20 February 2017 in IEEE Transactions on Power Electronics
This paper analyzes two fault-tolerant dual-multiphase motor drives, a series-connected topology, and a standard H-bridge topology. Previous studies have shown that the series connected topology is appropriate to an aerospace application and has lower peak current in degraded mode in comparison with the H-bridge topology, which may consequently diminish the system's weight and cost. This paper extends the study to compare different control strategies of these structures under two fault conditions: short-circuit of an inverter's switch and an open-phase of the machine. The control strategies analyzed in this paper do not impact the fundamental current or the torque generation, but the amplitudes of some harmonics in degraded mode are expected to be narrowed down in order to reduce the inverter's size. Some analyses of maximum voltage and peak current in degraded mode have been used for inverter dimensioning. Experimental results are shown and compared to the simulated ones to confirm the validity of this study.
Multi-phase machines are known for their fault-tolerant capability. However, star-connected machines have no fault tolerance to inverter switch short-circuit fault. This paper investigates the fault-tolerant operation of an open-end five-phase drive, i.e. a multi-phase machine fed with a dual-inverter supply. Inverter switch short-circuit faults are considered and handled with various degrees of reconfiguration. Theoretical developments and experimental results validate the proposed strategies.