Xiaoyun Zhao

Prof. Dr. Xiaoyun Zhao

Department of Respiratory and Critical Care Medicine & Sleep Center, Tianjin Chest Hospital, Tianjin 300222, China
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 March 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Xiaoyun ZhaoXiaoyun Zhao
Xiaoyun Zhao
XWXiaohong Wang
Xiaohong Wang
TYTianshun Yang
Tianshun Yang
SJSiyu Ji
Siyu Ji
HWHuiquan Wang
Huiquan Wang
QWQi Wu
Qi Wu
Sleep apnea syndrome (SAS) is a disorder in which respiratory airflow frequently stops during sleep. Alterations in electroencephalogram (EEG) signal are one of the physiological changes that occur during apnea, and can be used to diagnose and monitor sleep apnea events. Herein, we proposed a method to automatically distinguish sleep apnea events using characteristics of EEG signals in order to categorize obstructive sleep apnea (OSA) events, central sleep apnea (CSA) events and normal breathing events. Through the use of an Infinite Impulse Response Butterworth Band pass filter, we divided the EEG signals of C3-A2 and C4-A1 into five sub-bands. Next, we extracted sample entropy and variance of each sub-band. The neighbor composition analysis (NCA) method was utilized for feature selection, and the results are used as input coefficients for classification using random forest, K-nearest neighbor, and support vector machine classifiers. After a 10-fold cross-validation, we found that the average accuracy rate was 88.99%. Specifically, the accuracy of each category, including OSA, CSA and normal breathing were 80.43%, 84.85%, and 95.24%, respectively. The proposed method has great potential in the automatic classification of patients' respiratory events during clinical examinations, and provides a novel idea for the development of an automatic classification system for sleep apnea and normal events without the need for expert intervention.

20 December 2020 in Chronobiology International
Verified
Journal Article
Closed access
Ramón C. HermidaRamón C. Hermida
Ramón C. Hermida
MSMichael H. Smolensky
Michael H. Smolensky
HBHoria Balan
Horia Balan
RCRichard J. Castriotta
Richard J. Castriotta
JCJuan J. Crespo
Juan J. Crespo
Xiaoyun ZhaoXiaoyun Zhao
Xiaoyun Zhao
Current hypertension guidelines fail to provide a recommendation on when-to-treat, thus disregarding relevant circadian rhythms that regulate blood pressure (BP) level and 24 h patterning and medication pharmacokinetics and pharmacodynamics. The ideal purpose of ingestion-time (chronopharmacology, i.e. biological rhythm-dependent effects on the kinetics and dynamics of medications, and chronotherapy, i.e. the timing of pharmaceutical and other treatments to optimize efficacy and safety) trials should be to explore the potential impact of endogenous circadian rhythms on the effects of medications. Such investigations and outcome trials mandate adherence to the basic standards of human chronobiology research. In-depth review of the more than 150 human hypertension pharmacology and therapeutic trials published since 1974 that address the differential impact of upon-waking/morning versus at-bedtime/evening schedule of treatment reveals diverse protocols of sometimes suboptimal or defective design and conduct. Many have been “time-of-day,” i.e. morning versus evening, rather than circadian-time-based, and some relied on wake-time office BP rather than around-the-clock ambulatory BP measurements (ABPM). Additionally, most past studies have been of too small sample size and thus statistically underpowered. As of yet, there has been no consensual agreement on the proper design, methods and conduct of such trials. This Position Statement recommends ingestion-time hypertension trials to follow minimum guidelines: (i) Recruitment of participants should be restricted to hypertensive individuals diagnosed according to ABPM diagnostic thresholds and of a comparable activity/sleep routine. (ii) Tested treatment-times should be selected according to internal biological time, expressed by the awakening and bed times of the sleep/wake cycle. (iii) ABPM should be the primary or sole method of BP assessment. (iv) The minimum-required features for analysis of the ABPM-determined 24 h BP pattern ought to be the asleep (not “nighttime”) BP mean and sleep-time relative BP decline, calculated in reference to the activity/rest cycle per individual. (v) ABPM-obtained BP means should be derived by the so-called adjusted calculation procedure, not by inaccurate arithmetic averages. (vi) ABPM should be performed with validated and calibrated devices at least hourly throughout two or more consecutive 24 h periods (48 h in total) to achieve the highest reproducibility of mean wake-time, sleep-time and 48 h BP values plus the reliable classification of dipping status. (vii) Calculation of minimum required sample size in adherence with proper statistical methods must be provided. (viii) Hypertension chronopharmacology and chronotherapy trials should preferably be randomized double-blind, randomized open-label with blinded-endpoint, or crossover in design, the latter with sufficient washout period between tested treatment-time regimens.

17 November 2020 in IEEE Access
Verified
Journal Article
Open access
YWYao Wang
Yao Wang
SJSiyu Ji
Siyu Ji
TYTianshun Yang
Tianshun Yang
XWXiaohong Wang
Xiaohong Wang
HWHuiquan Wang
Huiquan Wang
Xiaoyun ZhaoXiaoyun Zhao
Xiaoyun Zhao
Hypopnea refers to the state in which insufficient alveolar ventilation during night sleep decreases the respiratory airflow by more than 50% of the airflow. However, sleep apnea is a more serious respiratory event, such as complete cessation of respiratory airflow for 10 seconds. The occurrence of hypopnea is a precursor to the occurrence of apnea events and the two are closely connected. In this paper, we propose a method based on the combination of discrete wavelet transform and approximate entropy of EEG signals to detect sleep apnea and hypopnea events. For this purpose, first, data preprocessing is performed on the EEG record data set obtained from Tianjin Chest Hospital, and then infinite impulse response (IIR) Butterworth bandpass filter is used to decompose the data into delta, theta, alpha, beta and gamma. Second, descriptive features are extracted based on sub-bands discrete wavelet transform such as the approximate entropy of high-frequency coefficients. Third, the features are filtered based on Support Vector Machine (SVM) recursive elimination. Finally, several machine learning algorithms including SVM, K-Nearest Neighbor (KNN) and Random forest (RF) are employed to identify the occurrence of sleep hypopnea-apnea events. The highest accuracy rate reached 94.33%, the sensitivity reached 93.10%, and the specificity reached 95.07%. The obtained results validate that the proposed method is an effective and practical diagnostic method to detect the occurrence of hypopnea-apnea events.

4 January 2022 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
YWYao Wang
Yao Wang
ZXZhuangwen Xiao
Zhuangwen Xiao
SFShuaiwen Fang
Shuaiwen Fang
WLWeiming Li
Weiming Li
JWJinhai Wang
Jinhai Wang
Xiaoyun ZhaoXiaoyun Zhao
Xiaoyun Zhao

18 April 2022 in The FASEB Journal
Verified
Journal Article
Open access
MKManale El Kharbili
Manale El Kharbili
KAKatja Aviszus
Katja Aviszus
SSSarah K. Sasse
Sarah K. Sasse
Xiaoyun ZhaoXiaoyun Zhao
Xiaoyun Zhao
KSKarina A. Serban
Karina A. Serban
FGFabienne Gally
Fabienne Gally
Resolution of inflammation is an active process that is tightly regulated to achieve repair and tissue homeostasis. In the absence of resolution, persistent inflammation underlies the pathogenesis of chronic lung disease such as chronic obstructive pulmonary disease (COPD) with recurrent exacerbations. Over the course of inflammation, macrophage programming transitions from pro‐inflammatory to pro‐resolving, which is in part regulated by the nuclear receptor Peroxisome Proliferator‐Activated Receptor γ (PPARγ). Our previous work demonstrated an association between Fatty Acid Binding Protein 5 (FABP5) expression and PPARγ activity in peripheral blood mononuclear cells of healthy and COPD patients. However, a role for FABP5 in macrophage programming has not been examined. Here, using a combination of in vitro and in vivo approaches, we demonstrate that FABP5 is necessary for PPARγ activation. In turn, PPARγ acts directly to increase FABP5 expression in primary human alveolar macrophages. We further illustrate that lack of FABP5 expression promotes a pro‐inflammatory macrophage programming with increased secretion of pro‐inflammatory cytokines and increased chromatin accessibility for pro‐inflammatory transcription factors (e.g., NF‐κB and MAPK). And finally, real‐time cell metabolic analysis using the Seahorse technology shows an inhibition of oxidative phosphorylation in FABP5‐deficient macrophages. Taken together, our data indicate that FABP5 and PPARγ reciprocally regulate each other's expression and function, consistent with a novel positive feedback loop between the two factors that mediates macrophage pro‐resolving programming. Our studies highlight the importance of defining targets and regulatory mechanisms that control the resolution of inflammation and may serve to inform novel interventional strategies directed towards COPD.

15 October 2021 in BMC Pulmonary Medicine
Verified
Journal Article
Open access
PDF file
HYHui Yu
Hui Yu
JZJing Zhao
Jing Zhao
DLDongyi Liu
Dongyi Liu
ZCZhen Chen
Zhen Chen
JSJinglai Sun
Jinglai Sun
Xiaoyun ZhaoXiaoyun Zhao
Xiaoyun Zhao
Background: Chronic obstructive pulmonary disease (COPD) is a chronic respiratory disease that seriously threatens people’s health, with high morbidity and mortality worldwide. At present, the clinical diagnosis methods of COPD are time-consuming, invasive, and radioactive. Therefore, it is urgent to develop a non-invasive and rapid COPD severity diagnosis technique suitable for daily screening in clinical practice. Results: This study established an effective model for the preliminary diagnosis of COPD severity using lung sounds with few channels. Firstly, the time-frequency-energy features of 12 channels lung sounds were extracted by Hilbert–Huang transform. And then, channels and features were screened by the reliefF algorithm. Finally, the feature sets were input into a support vector machine to diagnose COPD severity, and the performance with Bayes, decision tree, and deep belief network was compared. Experimental results show that high classification performance using only 4-channel lung sounds of L1, L2, L3, and L4 channels can be achieved by the proposed model. The accuracy, sensitivity, and specificity of mild COPD and moderate + severe COPD were 89.13%, 87.72%, and 91.01%, respectively. The classification performance rates of moderate COPD and severe COPD were 94.26%, 97.32%, and 89.93% for accuracy, sensitivity, and specificity, respectively. Conclusion: This model provides a standardized evaluation with high classification performance rates, which can assist doctors to complete the preliminary diagnosis of COPD severity immediately, and has important clinical significance.