Katarzyna Polak-Kraśna

Dr. Katarzyna Polak-Kraśna


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 August 2017 in Journal of Materials Chemistry A
Verified
Journal Article
Open access
PDF file
SRSebastien Rochat
Sebastien Rochat
KPKatarzyna Polak-Kraśna
Katarzyna Polak-Kraśna
Mi TianMi Tian
Mi Tian
LHLeighton T. Holyfield
Leighton T. Holyfield
Tim MaysTim Mays
Tim Mays
ABAndrew D. Burrows
Andrew D. Burrows
Microporous polymer-based membranes (PIM-1) doped with a porous aromatic framework (PAF-1) combine mechanical flexibility with enhanced hydrogen uptake capacities: they can potentially store up to 6.7 wt% H2at 77 K.

21 December 2016 in Journal of Materials Science
Verified
Journal Article
Open access
PDF file
KPKatarzyna Polak-Kraśna
Katarzyna Polak-Kraśna
Robert DawsonRobert Dawson
Robert Dawson
LHLeighton T. Holyfield
Leighton T. Holyfield
Chris BowenChris Bowen
Chris Bowen
ABAndrew D. Burrows
Andrew D. Burrows
Tim MaysTim Mays
Tim Mays
Polymers of intrinsic microporosity (PIMs) are currently attracting interest due to their unusual combination of high surface areas and capability to be processed into free-standing films. However, there has been little published work with regards to their physical and mechanical properties. In this paper, detailed characterisation of PIM-1 was performed by considering its chemical, gas adsorption and mechanical properties. The polymer was cast into films, and characterised in terms of their hydrogen adsorption at −196 °C up to much higher pressures (17 MPa) than previously reported (2 MPa), demonstrating the maximum excess adsorbed capacity of the material and its uptake behaviour in higher pressure regimes. The measured tensile strength of the polymer film was 31 MPa with a Young’s modulus of 1.26 GPa, whereas the average storage modulus exceeded 960 MPa. The failure strain of the material was 4.4%. It was found that the film is thermally stable at low temperatures, down to −150 °C, and decomposition of the material occurs at 350 °C. These results suggest that PIM-1 has sufficient elasticity to withstand the elastic deformations occurring within state-of-the-art high-pressure hydrogen storage tanks and sufficient thermal stability to be applied at the range of temperatures necessary for gas storage applications.

1 June 2021 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
KPKatarzyna Polak-Kraśna
Katarzyna Polak-Kraśna
AAAli Reza Abaei
Ali Reza Abaei
RSReyhaneh Neghabat Shirazi
Reyhaneh Neghabat Shirazi
EPEoin Parle
Eoin Parle
OCOliver Carroll
Oliver Carroll
TVTed Vaughan
Ted Vaughan
This study presents a systematic evaluation of the physical, thermal and mechanical performance of medical-grade semi-crystalline PLLA undergoing thermally-accelerated degradation. Samples were immersed in phosphate-buffered saline solution at 50 °C for 112 days and mass loss, molecular weight, thermal properties, degree of crystallinity, FTIR and Raman spectra, tensile elastic modulus, yield stress and failure stress/strain were evaluated at consecutive time points. Samples showed a consistent reduction in molecular weight and melting temperature, a consistent increase in percent crystallinity and limited changes in glass transition temperature and mass loss. At day 49, a drastic reduction in tensile failure strain was observed, despite the fact that elastic modulus, yield and tensile strength of samples were maintained. Brittleness increase was followed by rapid increase in degradation rate. Beyond day 70, samples became too brittle to test indicating substantial deterioration of their load-bearing capacity. This study also presents a computational micromechanics framework that demonstrates that the elastic modulus of a semi-crystalline polymer undergoing degradation can be maintained, despite a reducing molecular weight through compensatory increases in percent crystallinity. This study presents novel insight into the relationship between physical properties and mechanical performance of medical-grade PLLA during degradation and could have important implications for design and development of bioresorbable stents for vascular applications.

10 May 2019 in Adsorption
Verified
Journal Article
Open access
PDF file
Mi TianMi Tian
Mi Tian
SRSebastien Rochat
Sebastien Rochat
KPKatarzyna Polak-Kraśna
Katarzyna Polak-Kraśna
LHLeighton T. Holyfield
Leighton T. Holyfield
ABAndrew D. Burrows
Andrew D. Burrows
Tim MaysTim Mays
Tim Mays
The exploration and evaluation of new composites possessing both processability and enhanced hydrogen storage capacity are of significant interest for onboard hydrogen storage systems and fuel cell based electric vehicle development. Here we demonstrate the fabrication of composite membranes with sufficient mechanical properties for enhanced hydrogen storage that are based on a polymer of intrinsic microporosity (PIM-1) matrix containing nano-sized fillers: activated carbon (AX21) or metal–organic framework (MIL-101). This is one of the first comparative studies of different composite systems for hydrogen storage and, in addition, the first detailed evaluation of the diffusion kinetics of hydrogen in polymer-based nanoporous composites. The composite films were characterised by surface area and porosity analysis, hydrogen adsorption measurements, mechanical testing and gas adsorption modelling. The PIM-1/AX21 composite with 60 wt% AX21 provides enhanced hydrogen adsorption kinetics and a total hydrogen storage capacity of up to 9.35 wt% at 77 K; this is superior to the US Department of Energy hydrogen storage target. Tensile testing indicates that the ultimate stress and strain of PIM-1/AX21 are higher than those of the MIL-101 or PAF-1 containing composites, and are sufficient for use in hydrogen storage tanks. The data presented provides new insights into both the design and characterisation methods of polymer-based composite membranes. Our nanoporous polymer-based composites offer advantages over powders in terms of safety, handling and practical manufacturing, with potential for hydrogen storage applications either as means of increasing storage or decreasing operating pressures in high-pressure hydrogen storage tanks.

1 January 2019 in International Journal of Hydrogen Energy
Verified
Journal Article
Open access
SRSebastien Rochat
Sebastien Rochat
KPKatarzyna Polak-Kraśna
Katarzyna Polak-Kraśna
Mi TianMi Tian
Mi Tian
TMTimothy J. Mays
Timothy J. Mays
Chris BowenChris Bowen
Chris Bowen
ABAndrew D. Burrows
Andrew D. Burrows

1 March 2019 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
KPKatarzyna Polak-Kraśna
Katarzyna Polak-Kraśna
SRSandra Robak-Nawrocka
Sandra Robak-Nawrocka
SSSylwia Szotek
Sylwia Szotek
MCMarcin Czyż
Marcin Czyż
DGDaniel Gheek
Daniel Gheek
CPCelina Pezowicz
Celina Pezowicz