Vikrant C. Aute

Dr. Vikrant C. Aute

Department of Mechanical Engineering, Center for Environmental Energy Engineering, Maryland Energy Innovation Institute, University of Maryland, College Park, MD 20742-2115, USA

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 April 2013 in Structural and Multidisciplinary Optimization
Verified
Journal Article
Closed access
PDF file
VAVikrant C. Aute
Vikrant C. Aute
KSK. Saleh
K. Saleh
Omar AbdelazizOmar Abdelaziz
Omar Abdelaziz
SAS. Azarm
S. Azarm
RRR. Radermacher
R. Radermacher

21 July 2017 in Science and Technology for the Built Environment
Verified
Journal Article
Open access
DBDaniel Bacellar
Daniel Bacellar
VAVikrant C. Aute
Vikrant C. Aute
ZHZhiwei Huang
Zhiwei Huang
RRReinhard Radermacher
Reinhard Radermacher

1 July 2019 in International Journal of Refrigeration
Verified
Journal Article
Closed access
ZLZhenning Li
Zhenning Li
VAVikrant C. Aute
Vikrant C. Aute
JLJiazhen Ling
Jiazhen Ling

5 April 2017 in Science and Technology for the Built Environment
Verified
Journal Article
Closed access
JBJohn Bush
John Bush
MBMohamed Beshr
Mohamed Beshr
VAVikrant C. Aute
Vikrant C. Aute
RRReinhard Radermacher
Reinhard Radermacher
Transcritical CO2 booster refrigeration systems have seen a growing interest in recent years as they can provide two-stage refrigeration with R744, which has a global warming potential of 1.0, as the working fluid. However, the efficiency of these systems, particularly in transcritical operation, is often not as good as the efficiency of comparable conventional equipment. One possible way to improve performance in hot climates is through the use of a mechanical subcooler. This study describes laboratory testing of a lab-scale transcritical booster system, with and without mechanical subcooling and in transcritical and subcritical operating modes. In addition, a new steady-state model for generalized vapor compression systems was developed and is presented here. The model is used to simulate the system tested in the current article. The testing showed a significant improvement in both capacity and efficiency at all operating conditions with the subcooler. The solver was able to match capacity, power, and efficiency to within 3% for all test conditions. The model was used to perform a parametric study of subcooler capacity on the cycle; the results show that added subcooling substantially improves overall coefficient of performance and reduces the need for bypass flow, but the overall coefficient of performance benefit diminishes as the efficiency of the main cycle increases.

24 August 2016 in The International Journal of Life Cycle Assessment
Verified
Journal Article
Closed access
PDF file
MBMohamed Beshr
Mohamed Beshr
VAVikrant C. Aute
Vikrant C. Aute
Omar AbdelazizOmar Abdelaziz
Omar Abdelaziz
BFBrian Fricke
Brian Fricke
RRReinhard Radermacher
Reinhard Radermacher

1 February 2020 in International Journal of Refrigeration
Verified
Journal Article
Closed access
RERadia Eldeeb
Radia Eldeeb
VAVikrant C. Aute
Vikrant C. Aute
RRReinhard Radermacher
Reinhard Radermacher