To improve the problem of turbulence in the forebay of the lateral inlet pumping station, a typical lateral inlet pumping station project in Xuzhou, Jiangsu Province, China was taken as the research object. The forebay of the pumping station is a building connecting the river channel and the pumping station into the water tank. Based on the Reynolds-averaged Navier-Stokes (RANS) law and the k-ε turbulence model, the computational fluid dynamics method (CFD) technology compares and analyzes the numerical simulation with or without rectification measures for the forebay of the lateral intake pumping station when multiple units are operating. The three-dimensional model was created by SolidWorks modeling software and the numerical simulation simulated by CFX-ANSYS. To alter the flow pattern in the forebay of the pumping station, various rectification measures were chosen. Internal rectification flow patterns in the forebay under multiple plans, uniformity of flow velocity distribution in the measuring section, and vortex area reduction rates are investigated and compared. Based on the analysis and comparison of numerical simulation results, when the parabolic wall and some rectification piers are set significantly it improves the flow pattern of the forebay of the lateral inlet pumping station. It also makes the flow pattern of the inlet pool better and increases the uniformity of the flow velocity distribution by 8%. Further, it reduced the vortex area by 70%, effectively improving the operating efficiency of the pump. The research results of this paper provide a technical reference for the improvement of the flow pattern in the forebay of the lateral inlet pumping station.
In order to study the variation law of the flow field and pressure fluctuation in the hump section of the siphon outlet conduit, the flow field characteristics and frequency spectrum characteristics of the flow field were analyzed by combining a physical model test and numerical simulation under the conditions of the interaction between the axial flow pump and siphon outlet conduit, and the influence of the residual circulation at the outlet of the guide vane on the siphon outlet flow was investigated. Based on the influence of the flow field and hydraulic loss in the conduit, the equivalent surface method based on the Q criterion was used to analyze the vortex structure in the siphon outlet conduit and to analyze the internal vortex state. The results showed that with the increase of the flow rate, the intensity of the vortices in the cross-section of the hump section of the siphon outlet conduit decreased gradually, the average velocity circulation decreased gradually and the axial velocity distribution uniformity increased and tended to be stable; water flow stratification existed under three characteristic conditions with no circulation, and the hydraulic loss was greater with the circulation flow while it had a circulation under the small flow condition. Under the low flow rate conditions, the hydraulic loss was 6.6 times higher under the condition of circulation than without. Under a high flow condition, it was 1.3 times. Under the condition of a small flow rate, the vortex structure was distributed centrally at the inlet of the flow conduit, and under the other two characteristic conditions, the vortex structure mostly appeared as a strip; the pressure fluctuation in the hump section had obvious periodicity, and with the increase of the flow rate, the maximum pressure fluctuation amplitude in the hump section decreased gradually; with the decrease of the rotational speed, the pressure amplitude at the same measuring point in the hump section decreased gradually and at the optimum condition. Under the following conditions, the mean value of the pressure amplitude at the top of the hump section was reduced by 69.63%, and the mean value of the pressure amplitude at the bottom of the hump section was reduced by 63.5%. Under all the calculation conditions, the main frequency of pulsation at each measuring point of the hump section was twice the frequency of the rotation.
An axial-flow pump as a turbine (PAT), as compared to the conventional Francis turbine, has the advantages of not being restricted by the terrain and having lower cost to reverse the pump as a turbine for power generation. When an axial-flow pump is reversed as a turbine, the internal flow pattern is more complicated than when in the pump mode, which can cause instability in the whole system and result in degradation of the hydraulic performance and structural vibration. The impeller and guide vane are the core of the axial-flow PAT unit. This research compares the experimental and numerical simulation results in order to verify the energy performance and pressure pulsation signal of the axial-flow PAT. The unsteady flow regime, fluid force, and pressure pulsation characteristics of the impeller-guide vane hydraulic coupling zone are analyzed in detail. The findings demonstrate that both the dominant frequency of the fluid force pulsation signal and the flow field pressure pulsation signal appear at 3 times of the rotation frequency. The blade passing frequency (BPF) of the impeller is the dominant frequency, and other frequency components are also dominated by the harmonic frequency of the BPF. The impeller and guide vane are primarily subject to radial fluid force. Under partial working conditions, the pressure pulsation intensity in the flow field greatly increases, and the pressure pulsation amplitude at the guide vane outlet and impeller outlet appears to be more sensitive to the flow rate change.