Yahya Kurama

Yahya Kurama


Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2018 in Journal of Structural Engineering
Verified
Journal Article
Closed access
YKYahya Kurama
Yahya Kurama
SSSri Sritharan
Sri Sritharan
RFRobert B. Fleischman
Robert B. Fleischman
JRJose I. Restrepo
Jose I. Restrepo
RHRichard S. Henry
Richard S. Henry
PBPatricio Bonelli
Patricio Bonelli
Precast concrete facilitates a construction method using durable and rapidly erectable prefabricated members to create cost-effective and high-quality structures. In this method, the connections between the precast members as well as between the members and the foundation require special attention to ensure good seismic performance. Extensive research conducted since the 1980s has led to new precast concrete structural systems, designs, details, and techniques that are particularly suited for use in regions of high seismic hazard. This paper reviews the state of the art of these advances, including code developments and practical applications, related to four different systems: (1) moment frames; (2) structural walls; (3) floor diaphragms; and (4) bridges. It is concluded from this review that the widespread use of precast concrete in seismic regions is feasible today and that the jointed connection innovation introduced through precast research leads to improved seismic performance of building and bridge structures.

1 November 2013 in Journal of Structural Engineering
Verified
Journal Article
Closed access
BSBrian J. Smith
Brian J. Smith
YKYahya Kurama
Yahya Kurama
MMMichael J. McGinnis
Michael J. McGinnis
This paper discusses the lateral load behavior of two, 0.40-scale, hybrid, precast concrete shear wall test specimens and the behavior of a third precast specimen designed to emulate monolithic cast-in-place RC shear walls. The walls had identical overall geometry and were constructed by placing rectangular precast panels across horizontal joints. The hybrid walls used mild steel bars [Grade 400 (U.S. Grade 60)] and high-strength unbonded posttensioning (PT) strands for lateral resistance, whereas the emulative wall used only mild steel bars. The mild steel bars crossing the base joint were designed to yield and provide energy dissipation, with the PT steel in the hybrid walls reducing the residual displacements of the structure. The mild steel bars at the base of the emulative wall and one of the hybrid walls used Type II mechanical splices, while the other hybrid wall used continuous bars grouted into the foundation. Because of the lack of PT steel, the emulative wall developed a large residual ...

1 October 2011 in Journal of Structural Engineering
Verified
Journal Article
Closed access
BSBrian J. Smith
Brian J. Smith
YKYahya Kurama
Yahya Kurama
MMMichael J. McGinnis
Michael J. McGinnis
This paper presents the measured behavior from the testing of a 0.4-scale “hybrid” precast concrete wall specimen under reversed-cyclic lateral loading and provides an assessment of the seismic design and analysis of the wall by using the experimental results. The hybrid precast wall system investigated in the paper utilizes a combination of mild (i.e., Grade 400) steel and high-strength unbonded posttensioning (PT) steel for lateral resistance across horizontal joints. A seismic design procedure that conforms to ACI 318 and ACI ITG-5.2 was used for the design of the test specimen based on ACI ITG-5.1. The behavior of the specimen was measured with conventional data acquisition techniques and also full-field digital image correlation of the base panel and the critical joint between the base panel and the foundation, providing unprecedented information on the wall performance. The paper compares these measurements with the design and analytical predictions, focusing specifically on the applied lateral load and displacement, energy dissipation, behavior of the steel reinforcement, and behavior along the horizontal joints. The test specimen was not able to reach the expected ultimate drift level owing to a combination of poor unconfined concrete strength and poor placement of the confinement reinforcement at the toes. However, the performance of the wall up to the failure point was consistent with the predicted behavior based on both the design procedure and the analytical models.

1 November 2007 in Journal of Structural Engineering
Verified
Journal Article
Closed access
BMBrian G. Morgen
Brian G. Morgen
YKYahya Kurama
Yahya Kurama
This paper presents the seismic design of unbonded posttensioned precast concrete frame structures that use friction dampers for supplemental energy dissipation. A procedure is described to determine the friction damper slip forces and posttensioning steel areas needed to satisfy prescribed design lateral strength and energy dissipation requirements for a trial frame with given geometry, beam and column member dimensions, and selected damper distribution. The proposed design procedure assumes that the lateral strength requirements for the frame have been obtained from a linear elastic analysis of the structure under equivalent lateral forces. Nonlinear reversed-cyclic analyses of friction-damped precast concrete beam-column subassemblies and multistory frame structures under lateral loads are conducted to critically evaluate the design procedure and to identify areas where improvement may be needed. The analytical results show that friction-damped precast frames can be designed to achieve significant ener...

1 July 2010 in Journal of Structural Engineering
Verified
Journal Article
Closed access
SESherif El-Tawil
Sherif El-Tawil
KHKent A. Harries
Kent A. Harries
PFPatrick J. Fortney
Patrick J. Fortney
BSBahram M. Shahrooz
Bahram M. Shahrooz
YKYahya Kurama
Yahya Kurama
Hybrid coupled walls (HCWs) are comprised of two or more reinforced concrete wall piers connected with steel coupling beams distributed over the height of the structure. Extensive research over the past several decades suggests that such systems are particularly well suited for use in regions of moderate to high seismic risk. This paper reviews the state of the art in seismic modeling, analysis, and design of HCW systems. Design methodologies are presented in both prescriptive and performance-based design formats and a discussion of alterative types of hybrid wall systems is provided.

22 September 2003 in Earthquake Engineering & Structural Dynamics
Verified
Journal Article
Closed access
PDF file
YKYahya Kurama
Yahya Kurama
KFK. T. Farrow
K. T. Farrow