We investigated the effects of silver nanomaterials (AgNMs) on five well-characterized soils with distinct physicochemical properties using two standardized test systems. The carbon transformation test (OECD217) showed minimal sensitivity whereas the ammonia oxidizing bacteria test (ISO 15685) showed extreme sensitivity over 28 days of exposure. AgNM toxicity was compared with the physicochemical properties of the soils, revealing that toxicity declined with increasing clay content and increasing pH. AgNM toxicity did not appear to be affected by the organic carbon content of the soil. Our results showed that AgNM toxicity cannot be attributed to any single soil property but depends on the same parameters that determine the toxicity of conventional chemicals. Recommendations in the test guidelines for soil ecotoxicity studies are therefore applicable to AgNMs as well as conventional chemicals.
Silver nanoparticles (AgNPs) are widely used in many fields of application and consumer products due to their antibacterial properties. The aim of this study was to prepare a hazard assessment for one specific AgNP in soil, incorporated via sewage sludge (the sewage sludge pathway). The effects of pristine AgNPs on microorganisms, plants and earthworms were first determined in screening tests. Long-term tests over 140 days were then conducted with AgNPs added to soil via sewage sludge. AgNPs were incorporated into the sludge through a simulated sewage treatment plant (STP) over 10 days to allow transformation to occur and also by manual spiking over 2 h. The results of the most sensitive organism from the long-term tests, the soil microorganisms, are presented.
Increasing amounts of engineered nanoparticles (NPs) in wastewater can reach the aquatic environment by passing through the sewage treatment plant (STP). NPs can induce ecotoxicological effects due to their specific chemical properties. However, their bioavailability and toxicity are potentially influenced by transformation processes caused by substances present in the STP, e.g., humic acids or sulfides. Due to the lack of a test system allowing to test NPs under realistic environmental conditions, we coupled two existing test systems, the activated sludge simulation test (OECD TG 303A 2001) and the chronic exposure test with the freshwater amphipod Hyalella azteca (Environment Canada 2013), to gain a test scenario that allows to consider the altered behavior and fate of NPs induced by the STP process. This should improve the environmental realism of the chronic exposure test with Hyalella. In the first study, we tested the STP effluent containing AgNPs. In the second and third study, tap water and control STP effluent were spiked with AgNPs and used as test media. The chronic exposure studies with the freshwater amphipod H. azteca showed that the investigated AgNPs lose most of their toxicity while passing through the STP. Over all studies with total Ag concentrations ranging from 0.85 to 68.70 µg/L, significant effects of the AgNPs were only observed in the survival of test animals exposed to tap water containing the highest Ag concentration (62.59 µg/L). Accumulation of silver in the body of test animals was clearly dependent on the pretreatment of the AgNPs. Silver ions (Ag+) released from AgNPs are supposed to be the major pathway leading to body burden following exposure to test media containing AgNPs. The coupled test system is suitable for testing substances that can reach the environment via the STP effluent. The investigated AgNPs lose most of their toxicity while passing through the STP. Accumulation of silver in the animals exposed to the different treatments was apparent, whereby silver ions (Ag+) released from AgNPs were supposed to be the major pathway leading to body burden.
Nanomaterials enter the terrestrial environment via the repeated application of sludge to soils over many years. The goal of this investigation was to compare the effects of CuO and Ag nanomaterials on soil microorganisms after a single application and after repeated applications ultimately resulting in the same test concentrations. The effect on soil microorganisms was determined using the ammonium oxidation (ISO 15685), enzymatic activity patterns (ISO 22939) and MicroResp™ tests on days 28, 56 and 84. The comparability of single and repeated applications of ion-releasing nanomaterials depended on the test endpoint and duration. No significant differences between single and repeated applications were observed when testing nitrifying microorganisms and exoenzymes, but differences were observed in the substrate-induced respiration test. The three test systems used together provide more comprehensive information about the impact of different nanomaterials on the soil microflora and its diversity.
Sewage sludge is repeatedly applied as fertilizer on farmland due to its high nutrient content. This may lead to a significant increase of silver nanomaterials (AgNM) in soil over years. Therefore, our aim was to investigate the ecotoxicity and fate of AgNM under environmentally relevant conditions in outdoor lysimeters over 25 months. Two AgNM concentrations (1.7 and 8.0 mg/kg dry matter soil) were applied via sewage sludge into soil. In subsamples of the soil, incubated under laboratory conditions for 180 days, the comparability of outdoor and laboratory results regarding ecotoxicity was determined. The results from our long term lysimeter experiments show no detectable horizontal displacement in combination with very low remobilization to the percolate water. Thus, indicate that the sludge applied AgNM remains nearly immobile in the pathway between soils and leachate. However, Ag uptake to the roots of wheat and canola suggests that the chemical conditions in the rhizosphere induce AgNM remobilization from the incorporated sewage sludge even after two harvesting cycles. At the higher AgNM concentration a steady inhibition of the soil microflora was observed over 25 month in the lysimeter study, while there was no effect at the lower AgNM concentration. The results of the laboratory experiment reflect the findings of the lysimeter study and indicate that a risk assessment for AgNM based on data from laboratory tests is acceptable.