Total knee arthroplasty (TKA) surgery with manual instruments provides a quantitatively balanced knee in approximately 50% of cases. This study examined the effect of combining robotics technology with real-time intra-operative sensor feedback on the number of quantitatively balanced cases in a consecutive series of 200 robotic-assisted primary TKAs. The robotics platform was used to plan the implant component position using correctable poses in extension and a manual, centrally pivoting the balancer in flexion, prior to committing to the femoral cuts. During the initial trialing, the quantitative state of balance was assessed using an instrumented tibial tray that measured the intra-articular loads in the medial and lateral compartments. These sensor readings informed a number of surgical corrections, including bone recuts, soft-tissue corrections, and cement adjustments. During initial trialing, a quantitatively balanced knee was achieved in only 65% of cases. After performing the relevant soft-tissue corrections, bone recuts, and cement adjustments, 87% of cases ended balanced through the range of motion. Meanwhile, this resulted in a wide range of coronal alignment conditions, ranging from 6° valgus to 9° varus. It is therefore concluded that gaps derived from robotics navigation are not indicative for a quantitatively balanced knee, which was only consistently achieved when combining the robotics platform with real-time feedback from intra-operative load sensors.
Wearable sensors have the potential to facilitate remote monitoring for patients recovering from knee replacement surgery. Using IMU sensors attached to the patients’ leg, knee flexion can be monitored while the patients are recovering in their home environment. Ideally, these flexion angle measurements will have an accuracy and repeatability at least on par with current clinical standards. To validate the clinical accuracy of a two-sensor IMU system, knee flexion angles were measured in eight subjects post-TKA and compared with other in-clinic angle measurement techniques. These sensors are aligned to the patients’ anatomy by taking a pose resting their operated leg on a box; an initial goniometer measurement defines the patients’ knee flexion while taking that pose. The repeatability and accuracy of the system was subsequently evaluated by comparing knee flexion angles against goniometer readings and markerless optical motion capture data. The alignment pose was repeatable with a mean absolute error of 1.6 degrees. The sensor accuracy through the range of motion had a mean absolute error of 2.6 degrees. In conclusion, the presented sensor system facilitates a repeatable and accurate measurement of the knee flexion, holding the potential for effective remote monitoring of patients recovering from knee replacement surgery.
To achieve a balanced total knee, various surgical corrections can be performed, while intra-operative sensors and surgical navigation provide quantitative, patient-specific feedback. To understand the impact of these corrections, this paper evaluates the quantitative impact of both soft tissue releases and bone recuts on knee balance and overall limb alignment. This was achieved by statistically analyzing the alignment and load readings before and after each surgical correction performed on 479 consecutive primary total knees. An average of three surgical corrections were required following the initial bone cuts to achieve a well aligned, balanced total knee. Various surgical corrections, such as an arcuate release or increasing the tibial polyethylene insert thickness, significantly affected the maximum terminal extension. The coronal alignment was significantly impacted by pie-crusting the MCL, adding varus to the tibia, or releasing the arcuate ligament or popliteus tendon. Each surgical correction also had a specific impact on the intra-articular loads in flexion and/or extension. A surgical algorithm is presented that helps achieve a well-balanced knee while maintaining the sagittal and coronal alignment within the desired boundaries. This analysis additionally indicated the significant effect that soft tissue adjustments can have on the limb alignment in both anatomical planes.