Traditionally, analytical chemistry and diagnosis relied on wet laboratories and skilled professionals utilizing sophisticated instruments for sample handling and analysis. However, with the development of novel materials and sensing techniques, there has been a significant shift towards the use of standalone sensors, allowing tests to be conducted on-site or even in real time, leading to cost- and time-efficiency. With their widespread adoption globally, smartphones have emerged as an ideal platform for such sensors, boasting extensive sensor capabilities, advanced processing power, and communication functionalities. Smartphone-based assays make use of optical and electrochemical sensors, utilizing built-in cameras, ambient light sensors, and other features for optical sensing, while the micro-USB port, Bluetooth, and wireless connection facilitate data transmission and analog voltage application for electrochemical sensing. Previous overview papers have explored smartphone-based sensing in specific domains; this review provides a comprehensive examination of recent advancements in smartphone-based sensors, encompassing both optical and electrochemical sensing methods. The review provides the fundamental principles of these sensors and their implementation using smartphones, showcases recent applications, and presents innovative designs that take advantage of the inherent functionalities and sensor capabilities of smartphones. The review concludes by offering an outlook on the prospects of smartphone-based sensing and includes a reflective section emphasizing the potential impact of sensors in chemical and biological analyses. This comprehensive resource aims to provide information to researchers and practitioners interested in using smartphones for cutting-edge analytical methodologies.
Measurement of contact angle is important in many areas of science and engineering research. Contact angle analyzers are however not easily accessible due to their expensive cost, which hinders their use in research and also in education. In this study we propose a low-cost contact angle analyzer that can be assembled with 3D printed parts. Mobile phone is used for imaging, and the image is analyzed using an open-source ImageJ plugin. Commercial camera tripods are used as platform that provides movement in many degrees of freedom, which are important in leveling of the substrate and proper imaging of droplets. We utilize the tripods to build imaging modules, sample plate module and volume metering module, each of which perform distinct tasks. Especially, we characterize the usefulness of the volume metering module, which helps users dispense same volume of liquid to reduce human error during measurement. The cost of an analyzer is $255.10, which is an order of magnitude lower compared to commercial products. With the advancement in open source software and upgrades in the hardware modules, we expect that the proposed contact angle analyzer to have a positive impact in resource limited research labs and educational environments.
1 November 2021 in Sensors and Actuators B: Chemical
In a human host, bacterial Staphylococcus aureus and fungal Candida albicans pathogens form a mixed biofilm that causes severe mortality and morbidity. However, research on the formation and eradication of mixed biofilms under dynamic conditions is lacking. Thus, this study employed a microfluidic technique to analyze the real-time formation of mono- and dual-species (S. aureus and C. albicans) biofilms and noninvasive optical treatment of the established mature biofilm using 405-nm laser light. A herringbone mixer thoroughly mixed both bacterial and fungal cells in the growth media before being injected into the observation channels on the microfluidic chip. At a flow rate of 1.0 µL/min of growth media for 24 h, the bacterial biofilm coverage was up to 15% higher than that of the fungal biofilm (50% for bacteria vs. 35% for fungus). On the other hand, the dual-species biofilm yielded the highest coverage of ~ 96.5% because of the collective interaction between S. aureus and C. albicans. The number of cell proliferation events in S. aureus was higher than that of C. albicans for 12 h, which indicates that the S. aureus biofilm was developed faster than C. albicans. The novel in situ test platform showed a significant bactericidal effect (80%) of the 405-nm laser light at 1080 J/cm2 towards the established S. aureus biofilm, whereas the same treatment removed approximately 69% of the mixed cells in the dual-species biofilm. This study revealed that the developed microfluidic platform could be utilized to monitor the formation of dual-species biofilms in real-time and laser-induced antimicrobial effects on dual-species biofilms.
We present a low cost, 3D printed open-source antibody dispenser that can be easily built and used for the development of lateral flow assay (LFA) strips. The fabrication of LFA strips need dispensing of antibodies or antigens in a linear fashion and commercially available dispensers typically cost from few thousands to few tens of thousands of US dollars. In this paper, an antibody dispenser was built by using 3D printed and commercially available parts, which cost no more than 30 USD. This paper presents a detailed instruction on how to assemble the printer and how to achieve a specific line width for the dispensed antibody. By using syringe needles of different gauges, line width ranging from 0.23 to 1.8 mm can be dispensed, and by varying the speed controller, the dispensing needle’s speed can be varied between 2.8 and 3.8 cm/s. We demonstrate uniform dispensing of anti-C-reactive protein (CRP) antibody and anti-rabbit antibody to draw a test line and a control line, which are used for the detection of CRP. The dispenser can also be equipped with two dispensing needles to allow simultaneous dispensing of multiple reagents, which can be useful for LFA strip development.