In vivo, cardiomyocytes are exposed to multiple biochemical and physical cues including topographical and electrical cues. During prolonged in vitro cultivation in standard tissue culture set-ups, cardiomyocytes are known to de-differentiate due to the lack of appropriate micro-environmental cues. Most currently available cell culture systems provide only a single biophysical cue, thus development of advanced cell cultivation systems incorporating multiple cues is urgently needed. We report here the development of a microfabricated system, incorporating topographical and electrical cues on a single chip, which enables cultivation of differentiated cardiomyocytes. The cell culture chips were created by hot embossing of polystyrene, to create microgrooves and microridges of precisely defined depth, width and periodicity. Substrates consisting of 0.5 µm-wide grooves and 0.5 µm-wide ridges (1 µm period) and those consisting of 3 µm-wide grooves and 1 µm-wide ridges (4 µm period) were investigated, with smooth surfaces used as controls. The depth of the microgrooves was 400 nm. The two gold electrodes were electrodeposited 1 cm apart such that the microgrooves in-between were oriented either parallel or perpendicular to the electrodes, enabling studies of interaction between topographical and electrical cues. Neonatal rat cardiomyocytes cultivated on microgrooved substrates for 7 days were elongated and aligned along the microgrooves forming a well developed contractile apparatus, as evidenced by sarcomeric α-actinin staining, with a more pronounced effect on substrates with 1µm compared to 4 µm periodicity. Importantly, simultaneous application of biphasic electrical pulses and topographical cues resulted in gap junctions confined to the cell-cell end junctions rather than the punctate distribution found in neonatal cells. Electrical field stimulation further enhanced cardiomyocyte elongation when microgrooves were oriented parallel to the electric field. Due to the compatibility of the described cell culture chips with fluorescence and optical microscopy as well as the ability to independently control field stimulation parameters, biochemical and topographical cues on each chip, this system may in the future become a useful tool in drug development and maturation of cardiomyocytes derived from stem cells.
This paper reports a novel method of controlling liquid motion on a centrifugal microfluidic platform based on the integration of a regulated pressure pump and a programmable electromechanical valving system. We demonstrate accurate control over the displacement of liquids within the system by pressurizing simultaneously multiple ports of the microfluidic device while the platform is rotating at high speed. Compared to classical centrifugal microfluidic platforms where liquids are solely driven by centrifugal and capillary forces, the method presented herein adds a new degree of freedom for fluidic manipulation, which represents a paradigm change in centrifugal microfluidics. We first demonstrate how various core microfluidic functions such as valving, switching, and reverse pumping (i.e., against the centrifugal field) can be easily achieved by programming the pressures applied at dedicated access ports of the microfluidic device. We then show, for the first time, that the combination of centrifugal force and active pneumatic pumping offers the possibility of mixing fluids rapidly (~0.1 s) and efficiently based on the creation of air bubbles at the bottom of a microfluidic reservoir. Finally, the suitability of the developed platform for performing complex bioanalytical assays in an automated fashion is demonstrated in a DNA harvesting experiment where recovery rates of about 70% were systematically achieved. The proposed concept offers the interesting prospect to decouple basic microfluidic functions from specific material properties, channel dimensions and fabrication tolerances, surface treatments, or on-chip active components, thus promoting integration of complex assays on simple and low-cost microfluidic cartridges.
16 December 2010 in The Journal of Physical Chemistry C
This paper describes the development of an on-chip nucleic acid (NA) extraction assay from whole blood using a centrifugal microfluidic platform that allows for pneumatic actuation of liquids during rotation. The combination of pneumatic and centrifugal forces makes it possible to perform fluidic operations without the need for integrating active control elements on the microfluidic cartridge. The cartridge is fabricated from thermoplastic polymers (e.g., Zeonor 1060R) and features a simple design that is compatible with injection molding. In addition, the cartridge is interfaced with two external vials for off-chip storage of the blood sample and retrieval of the eluted NA solution, respectively. On-chip capture of NAs is performed using an embedded solid-phase extraction matrix composed of commercial glass microfiber filters (Whatman GF/D and GF/F). The yield of the automated, on-chip extraction protocol, determined by measuring absorbance at 260 nm, is comparable to some of the best manually operated kits (e.g., Qiagen QIAamp DNA Mini Kit) while providing low assay-to-assay variability due to the high level of control provided by the platform for each processing step. The A260/A280 and A260/A230 ratios of the absorbance spectra also reveal that protein contamination of the sample is negligible. The capability of the pneumatic platform to circulate air flux through the microfluidic conduit was used to dry leftover ethanol residues retained in the capture matrix during washing. This method, applied in combination with localized heating, proved effective for reducing ethanol contamination in eluted samples from ∼12% to 1% (v/v).
Infections caused by foodborne pathogens such as Listeria monocytogenes pose a threat to public health while timely detection is challenging due to pathogen low numbers. The development of robust and efficient sample preparation techniques is crucial to improve detection sensitivity and workflow. Immunomagnetic separation using magnetic nanoparticles (MNPs) is attractive, as it can efficiently capture target cells. For food safety applications, a platform is needed to rapidly process large sample volumes, allowing capture and release of target bacteria conjugated to immunomagnetic nanoparticles (IMNPs). Herein, we demonstrate a method for magnetic capture and release of bacteria-IMNPs complex based on a 3D magnetic trap integrated on a polymeric microfluidic device. The 3D magnetic capture region consist of a dense array of high-aspect ratio (3 : 1) cylindrical pillars embossed in thermoplastic polymer and coated with soft ferromagnetic nickel by an electroless deposition technique. This allows the generation of strong and switchable magnetic capture regions due to the very low remanence of the nickel shell. We propose and validate an optimized configuration of capture regions for efficient localized capture and rapid release of MNPs and IMNPs conjugated to L. monocytogenes. A maximum recovery rate for MNPs corresponded to 91% while a maximum capture efficiency of 30% was obtained for live bacteria, with a minimum detectable sample concentration of ~10 cfu ml−1 in 1 ml volume using plate-culture method. We believe that the flexible design and low-cost fabrication process of the proposed system will allow rapid sample preparation for applications beyond food and water safety, including point-of-care diagnosis.