Repeated blood pressure (BP) measurements allow better control of hypertension. Current measurements rely on cuff-based devices. The aim of the present study was to compare BP measurements using a novel cuff-less photoplethysmography-based device to a standard sphygmomanometer device. Males and females were recruited from within the general population who arrived at a public BP screening station. One to two measurements were taken from each using a sphygmomanometer-based and the photoplethysmography-based devices. Devices were considered equal if the mean difference between paired measurements was below 5 mmHg and the Standard Deviation (SD) was no greater than 8 mmHg. Agreement and reliability analyses were also performed. 1057 subjects were included in the study analysis. There were no adverse events during the study. The mean (± SD) difference between paired measurements for all subjects was -0.1 ± 3.6 mmHg for the systolic and 0.0 ± 3.5 mmHg for the diastolic readings. We found 96.31% agreement in identifying hypertension and an Interclass Correlation Coefficient of 0.99 and 0.97 for systolic and diastolic measurements, respectively. The photoplethysmography-based device was found similar to the gold-standard sphygmomanometer-based device with high agreement and reliability levels. The device might enable a reliable, more convenient method for repeated BP monitoring.
Toxins are hazardous biochemical compounds derived from bacteria, fungi, or plants. Some have mechanisms of action and physical properties that make them amenable for use as potential warfare agents. Currently, some toxins are classified as potential biological weapons, although they have several differences from classic living bio-terror pathogens and some similarities to manmade chemical warfare agents. This review focuses on category A and B bio-terror toxins recognized by the Centers for Disease Control and Prevention: Botulinum neurotoxin, staphylococcal enterotoxin B, Clostridium perfringens epsilon toxin, and ricin. Their derivation, pathogenesis, mechanism of action, associated clinical signs and symptoms, diagnosis, and treatment are discussed in detail. Given their expected covert use, the primary diagnostic challenge in toxin exposure is the early detection of morbidity clusters, apart from background morbidity, after a relatively short incubation period. For this reason, it is important that clinicians be familiar with the clinical manifestations of toxins and the appropriate methods of management and countermeasures.
BACKGROUND: Ambulatory blood pressure monitoring (ABPM) using cuff-based devices is used for diagnosis and treatment of hypertension. Technical limitations, low compliance, and complex procedures limit their use. The aim of the present study was to test the accuracy of a new photoplethysmography-based, wearable device (Wrist-monitor) as compared with the standard cuff-based ABPM device. METHODS: Twenty-four-hour (24H) ABPM was performed in parallel for both devices on volunteers aged 18–65 years, while documenting their daily activities. Level of comfort and activity disturbance of both devices were recorded. Linear regression and Bland–Altman were used to evaluate the agreement between devices. Receiver operating characteristic (ROC) curve analysis was used to classify hypertension based on the average Wrist-monitor measurements as compared with a cuff-based ABPM device. RESULTS: The study included 28 subjects (18 men) mean age 41.5 ± 16.2 years. Bland–Altman analysis resulted in 24H bias of −1.1 mm Hg for both diastolic blood pressure (DBP) and systolic blood pressure (SBP). Mean daytime bias was −1.9 mm Hg for DBP and SBP, while nighttime bias was smaller (0.7 and 0.4 mm Hg for DBP and SBP, respectively). ROC curve analysis yielded a mean area under the curve (AUC) of 1 for SBP and 24H blood pressure measurements. AUCs of 0.994 and 0.955 were found for the daytime DBP and night DBP, respectively. 24H ABPM with the Wrist-monitor caused significantly less inconvenience compared with the cuff-based device (P < 0.001). CONCLUSIONS: The cuffless device provides comparable measurements to those obtained with the currently used cuff-based ABPM device, with significantly less inconvenience to the subject. Clinical trials registration: Trial Number NCT03810586.
Accurate and continuous monitoring of critically ill patients is frequently achieved using invasive catheters, which is technically complex. Our purpose was to evaluate the validity and accuracy of a photoplethysmography (PPG)-based remote monitoring device compared to invasive methods of arterial line (AL) and Swan-Ganz (SG) catheters in a swine model of controlled hemorrhagic shock. Following a baseline phase, hemorrhagic shock was induced in 11 pigs by bleeding 35% of their blood volume, followed by a post-bleeding follow-up phase. Animals were monitored concomitantly by the PPG device, an AL and a SG catheter, for a median period of 447 min. Heart rate (HR), systolic and diastolic blood pressure (SBP and DBP, respectively), and cardiac output (CO) were recorded continuously. The complete data set consisted of 1312 paired observations. Correlations between the PPG-based technique and the invasive methods were significant (p < 0.001) during baseline, bleeding and follow-up phases for HR (r = 0.90–0.98), SBP (r = 0.90–0.94), DBP (r = 0.89–0.93), and CO (r = 0.76–0.90). Intraclass correlations for all phases combined were 0.96, 0.92, 0.93 and 0.87 for HR, SBP, DBP and CO, respectively. Correlations for changes in CO, SBP and DBP were significant (p < 0.001) and strong (r > 0.88), with concordance rates (determined by quadrant plots) of 86%, 66% and 68%, respectively. The novel PPG-based device was accurate and valid compared to existing invasive techniques and might be used for continuous monitoring in several clinical settings following further studies.
1 November 2017 in American Journal of Infection Control