Roman Studenikin

Dr. Roman Studenikin


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 August 2021 in International Journal of Dentistry
Verified
Journal Article
Open access
PDF file
RSRoman Studenikin
Roman Studenikin
SNSabukhi Niftaliev
Sabukhi Niftaliev
Introduction. Reducing the time of implant integration and the period of prosthetics is an important task of dentistry since this leads to improved quality of life and successful rehabilitation of the patient. Therefore, currently, there is an intensely increased interest in immediate or early loading of the implant, when certain parameters of primary implant stability in the bone tissue are achieved. Materials and Methods. The materials used to perform the procedure for placement of a customized provisional composite abutment were a provisional prefabricated abutment with a retention grip for the composite; aluminum oxide powder with a particle size of 27 mu m for better adhesion of the composite, with which the retention grip of the provisional abutment is coated; 3M Single Bond Universal light-curing adhesive applied to the provisional abutment; and Filtek Bulk Fill 3M composite including a low-viscosity radiopaque nanocomponent and ytterbium trifluoride filler with a particle size of 0.01-3.5 nm. Methods used in this study were as follows: fabrication technique using the Cervico system for a customized provisional composite abutment; sandblasting of the provisional abutment using the apparatus RONDOFLEX (KERR); light polymerization of low-viscosity composite using Demi Ultra Kerr lamp (luminous flux power not less than 1100 mW/cm(2)); and radiographic control of the abutment fit in the implant. Results. The surgical and orthopedic treatment of 20 patients was performed using this technique. The control group consisted of 11 patients with similar pathology, in whose surgery the fabrication of a provisional prosthesis was used. As a result, it was possible to form a gingival profile, in comparison with the control group, to accelerate mucogingival and bone integration, as well as to quickly carry out orthopedic rehabilitation of the patient. The average value of the time required for the final formation of soft tissues for prosthetics in patients in the experimental group was significantly lower than those in the comparison group (p=0.007 and p=0.028, respectively). In most clinical cases, there is no need for surgery on soft tissues, which eliminates the possibility of additional traumas. Conclusions. The use of a promising technology for the fabrication of a crown on the implant and a customized provisional composite abutment significantly reduced the period of orthopedic rehabilitation of the patient. Immediate implantation with a customized provisional composite abutment completely forms the gingival profile, reduces the risk of microbial contamination in the area of bone formation, minimizes soft tissue ischemia, and accelerates the processes of mucogingival and bone integration around the implant.

30 December 2017 in The Journal of scientific articles "Health and Education millennium"
Verified
Journal Article
Open access
RSRoman Studenikin
Roman Studenikin
OSO.V. Serikova
O.V. Serikova

20 April 2021 in International Journal of Dentistry
Verified
Journal Article
Open access
PDF file
RSRoman Studenikin
Roman Studenikin
The removable platform switching technology (multiunit, On1) was tested intraoperatively using the passive placement technique as exemplified by a conical connection implant system, which makes it possible to visually control the placement of these platforms with respect to the alveolar bone in the correct orthopedic position. The technology is characterized by a rapid epithelialization of tissues around the base platform until the final integration of the implant, minimal trauma in the emergence profile zone, and an improved minimally invasive orthopedic protocol for working on a removable platform switching base.

21 December 2021 in Stomatology for all / International Dental Review
Verified
Journal Article
Closed access
RSRoman Studenikin
Roman Studenikin
AMA.A. Mamedov
A.A. Mamedov
According to the literature, was made overview of the current state of development of CAD/CAM technology: the optical and mechanical scanners used, software, methods of implementing production technology, milling devices, materials used, features of dental preparation. The technology of full digitalization of dental restoration proposed by the authors is described in detail including all stages from computer-aided design to the production of dentures. The technique has been tested on 20 patients. The conclusions note the competitive advantages of the technology used and its existing disadvantages.

7 April 2022 in Medical alphabet
Verified
Journal Article
Closed access
PDF file
RSRoman Studenikin
Roman Studenikin
AMA. A. Mamedov
A. A. Mamedov
Purpose. The purpose of the study was to evaluate the stability during healing and before loading of implants placed at different levels depending on the texture of their neck.Materials and methods. The study included patients with the same type of bone (type II), who were implanted with screw implants with a conical connection: – parallel walls (polished collar – 0.3 mm), installed at the level of the alveolar ridge without immersion (group A); – root-shaped with micro-thread in the collar area, set below the level of the alveolar ridge by 1 mm (group B); – root-shaped (polished collar – 0.75 mm), installed above the level of the alveolar ridge by 1 mm (group B).All implants were used with shapers. The values of the implant stability coefficient (ISQ) were determined using resonance frequency analysis immediately after implant placement during surgery and 1, 4, 8 and 12 weeks after it. Other evaluated stability factors are the diameter and length of the implant, the place of their installation (upper or lower jaw).Results. A total of 60 implants were evaluated (20 in each group). Mean ISQ values at baseline on the day of surgery and 1 week after insertion were significantly higher in group B (p=0.006, p=0.022 and p=0.031, respectively, for groups B, C, A). There were no differences at subsequent observation points. The ISQ value was higher for wide (diameter – 4.3 mm) implants than with a smaller diameter value (3.5 mm) and for mandibular implants than for maxillary implants at all points of observation. Neglecting the diameter data, the length of the implant did not affect the ISQ values.Conclusion. Inserting the implant deeper into the bone may only matter for primary stability. Moreover, the diameter of the implant and its location affect the primary and secondary stability before loading, while the length of the implant does not play an important role if the diameter is not taken into account.

20 July 2023 in Эндодонтия Today
Verified
Journal Article
Open access
PDF file
RSRoman Studenikin
Roman Studenikin
ASA. V. Sushchenko
A. V. Sushchenko
AMA. A. Mamedov
A. A. Mamedov
Aim. Comparison of the secondary stability and osseointegration rate of dental implants with fine and coarse threads placed in bones of various types.Materials and Methods. The study considered the data of 60 implants with fine and coarse threads, installed in the bone types I-III. After two and six months, an analysis of the loss of marginal bone, micromotion tests were carried out, changes in the stability coefficients were determined by the method of frequency magnetic resonance.Results. The 30 coarse threaded implants showed higher secondary stability compared to the finely threaded implants in all three bone types. Marginal bone loss was observed for both types of implants only in type III bone – but when comparing the absolute values, it is noticeable that they are smaller with large threads. Micromotion was absent in all cases for bone types I and II. For implants with large threads in type III bone, micromotion was less than 30 μm, and for implants with fine threads, it was 150-160 μm.Conclusions. High secondary stability is typical for implants installed in type I-II bone, regardless of the thread pitch, but the value of the stability coefficient is higher for specimens with coarse threads. In addition, there is no loss of marginal bone in these cases. Finely threaded implants placed in Type III bone are subject to micromovement.