Raquel Catalán Carrió

Ms. Raquel Catalán Carrió

Universidad del País Vasco
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2021 in Analytica Chimica Acta
Verified
Journal Article
Open access
JSJanire Saez
Janire Saez
Raquel Catalán CarrióRaquel Catalán Carrió
Raquel Catalán Carrió
RORóisín M. Owens
Róisín M. Owens
LBLourdes Basabe-Desmonts
Lourdes Basabe-Desmonts
Fernando Benito-LopezFernando Benito-Lopez
Fernando Benito-Lopez
Water quality monitoring of drinking, waste, fresh and seawaters is of great importance to ensure safety and wellbeing for humans, fauna and flora. Researchers are developing robust water monitoring microfluidic devices but, the delivery of a cost-effective, commercially available platform has not yet been achieved. Conventional water monitoring is mainly based on laboratory instruments or sophisticated and expensive handheld probes for on-site analysis, both requiring trained personnel and being time-consuming. As an alternative, microfluidics has emerged as a powerful tool with the capacity to replace conventional analytical systems. Nevertheless, microfluidic devices largely use conventional pumps and valves for operation and electronics for sensing, that increment the dimensions and cost of the final platforms, reducing their commercialization perspectives. In this review, we critically analyze the characteristics of conventional microfluidic devices for water monitoring, focusing on different water sources (drinking, waste, fresh and seawaters), and their application in commercial products. Moreover, we introduce the revolutionary concept of using functional materials such as hydrogels, poly(ionic liquid) hydrogels and ionogels as alternatives to conventional fluidic handling and sensing tools, for water monitoring in microfluidic devices.

19 August 2015 in Langmuir
Verified
Journal Article
Closed access
ACAlejandro Cuenca
Alejandro Cuenca
JAJerónimo Agrisuelas
Jerónimo Agrisuelas
Raquel Catalán CarrióRaquel Catalán Carrió
Raquel Catalán Carrió
JGJosé Juan García-Jareño
José Juan García-Jareño
FVFrancisco Vicente
Francisco Vicente

26 December 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Raquel Catalán CarrióRaquel Catalán Carrió
Raquel Catalán Carrió
TATugce Akyazi
Tugce Akyazi
LBLourdes Basabe-Desmonts
Lourdes Basabe-Desmonts
Fernando Benito-LopezFernando Benito-Lopez
Fernando Benito-Lopez
The main problem for the expansion of the use of microfluidic paper-based analytical devices and, thus, their mass production is their inherent lack of fluid flow control due to its uncontrolled fabrication protocols. To address this issue, the first step is the generation of uniform and reliable microfluidic channels. The most common paper microfluidic fabrication method is wax printing, which consists of two parts, printing and heating, where heating is a critical step for the fabrication of reproducible device dimensions. In order to bring paper-based devices to success, it is essential to optimize the fabrication process in order to always get a reproducible device. Therefore, the optimization of the heating process and the analysis of the parameters that could affect the final dimensions of the device, such as its shape, the width of the wax barrier and the internal area of the device, were performed. Moreover, we present a method to predict reproducible devices with controlled working areas in a simple manner.

30 June 2015 in Journal of the Electrochemical Society
Verified
Journal Article
Closed access
PDF file
Raquel Catalán CarrióRaquel Catalán Carrió
Raquel Catalán Carrió
JAJerónimo Agrisuelas
Jerónimo Agrisuelas
ACA. Cuenca
A. Cuenca
JGJosé Juan García-Jareño
José Juan García-Jareño
Antoni F Roig-NavarroAntoni F Roig-Navarro
Antoni F Roig-Navarro
FVF. Vicente
F. Vicente
The simultaneous measurement of current, mass, motional resistance and absorbance magnitudes allows the electrochemical cation insertion process to be explained during successive voltammograms around the Prussian Blue ⇄ Everitt's Salt system in CsCl aqueous acid solutions. Two different ways for the entrance of cesium to the porous structure of Prussian Blue have been observed. Firstly, Cs+ is spontaneously absorbed as CsCl into the interstitial cluster of water of the channels formed by the Fe(II)low spin−CN−Fe(III)high spin structural units of the crystal. This chemical absorption involves a spontaneous substitution of inner water molecules of the interstitial water cluster. Finally, Cs+ can act as a counter-ion during electrochemical stabilization process of Prussian Blue by means of successive voltammograms.

7 July 2017 in ECS Transactions
Verified
Journal Article
Closed access
PDF file
JAJeronimo Agrisuelas
Jeronimo Agrisuelas
Raquel Catalán CarrióRaquel Catalán Carrió
Raquel Catalán Carrió
ACAlejandro Cuenca
Alejandro Cuenca
JGJosé Juan García-Jareño
José Juan García-Jareño
ARAntoni Francesc Roig
Antoni Francesc Roig
FVFrancisco Vicente
Francisco Vicente
The simultaneous measurement of current, mass and motional resistance magnitudes allows explaining the electrochemical cation insertion process during successive voltammograms around the Prussian Blue ⇄ Everitt's Salt system in an aqueous solution of CsCl. There are two different ways for entering cesium to the porous structure of Prussian Blue: one, enters chemically as CsCl by a spontaneous substitution of inner water molecules of the interstitial water cluster and, also can enter as counter-ion during the first cathodic scan of the electrochemical stabilisation process of Prussian Blue.