Yu Sogo

Dr. Yu Sogo


Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2002 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
AIAtsuo Ito
Atsuo Ito
HKHaruo Kawamura
Haruo Kawamura
MOMakoto Otsuka
Makoto Otsuka
MIMasako Ikeuchi
Masako Ikeuchi
HOHajime Ohgushi
Hajime Ohgushi
NINoboru Ichinose
Noboru Ichinose


25 September 2015 in Angewandte Chemie International Edition
Verified
Journal Article
Closed access
PDF file
XWXiupeng Wang
Xiupeng Wang
XLXia Li
Xia Li
AIAtsuo Ito
Atsuo Ito
YWYohei Watanabe
Yohei Watanabe
YSYu Sogo
Yu Sogo
TOTadao Ohno
Tadao Ohno

1 July 2005 in Current Applied Physics
Verified
Journal Article
Closed access
AIAtsuo Ito
Atsuo Ito
MOMakoto Otsuka
Makoto Otsuka
HKHaruo Kawamura
Haruo Kawamura
MIMasako Ikeuchi
Masako Ikeuchi
HOHajime Ohgushi
Hajime Ohgushi
NINoboru Ichinose
Noboru Ichinose

1 March 2010 in Acta Biomaterialia
Verified
Journal Article
Closed access
XWXiupeng Wang
Xiupeng Wang
AIAtsuo Ito
Atsuo Ito
YSYu Sogo
Yu Sogo
XLXia Li
Xia Li
AOAyako Oyane
Ayako Oyane

5 January 2017 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
KFKengo Fujii
Kengo Fujii
AIAtsuo Ito
Atsuo Ito
HMHirotaka Mutsuzaki
Hirotaka Mutsuzaki
SMShinji Murai
Shinji Murai
YSYu Sogo
Yu Sogo
Masashi YamazakiMasashi Yamazaki
Masashi Yamazaki
Loosening of screws is a common problem in orthopedic and maxillofacial surgery. Modifying the implant surface to improve the mechanical strength of screws has been tried and reported. We developed screws coated with fibroblast growth factor-2 (FGF-2)−apatite composite layers. We then showed, in a percutaneous external fixation model, that this composite layer had the ability to hold and release FGF-2 slowly, thereby reducing the risk of pin tract infection of the percutaneous external fixation. The objective of the current study was to clarify the effect of FGF-2−apatite composite layers on titanium screws on bone formation around the screw. We analyzed samples of previously performed animal experiments. The screws were coated with FGF-2−apatite composite layers by immersing them in supersaturated calcium phosphate solutions containing FGF-2. Then, the uncoated, apatite-coated, and FGF-2−apatite composite layer-coated screws were implanted percutaneously in rabbits. Finally, using inflammation-free histological sections, we histomorphometrically assessed them for the presence of bone formation. Weibull plot analysis was then applied to the data. On average, screws coated with FGF-2−apatite composite layers showed a significantly higher bone apposition rate than the uncoated or apatite-coated screws. Although the difference in the average bone apposition rate was small, the FGF-2−apatite composite layers produced a significant, marked reduction in the incidence of impaired bone formation around the screw compared with the incidence in the absence of FGF-2 (uncoated and apatite-coated screws). The probability of resulting in a bone apposition rate equal to or less than 63.75%, for example, is 3.5 × 10-4 for screws coated with the FGF-2−apatite composite layers versus 0.05 for screws in the absence of FGF-2. FGF-2-apatite composite layer coating significantly reduced the risk of impaired bone apposition to the screw. Thus, it is feasible to use titanium screws coated with FGF-2−apatite composite layers as internal fixation screws to decrease the risk of loosening.