Diego Paredes-Cuervo

Dr. Diego Paredes-Cuervo

Universidad Tecnológica de Pereira
orcid

Research Focus & Metrics

Academic Career Length

57Years (1970-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 May 2016 in Environmental Science and Pollution Research
Verified
Journal Article
Closed access
PDF file
Zhongbing ChenZhongbing Chen
Zhongbing Chen
DPDiego Paredes-Cuervo
Diego Paredes-Cuervo
Jochen MuellerJochen Mueller
Jochen Mueller
AWArndt Wiessner
Arndt Wiessner
HKHeinz Köser
Heinz Köser
PKPeter Kuschk
Peter Kuschk

6 June 2016 in Environmental Technology
Verified
Journal Article
Closed access
EBEliana Bohórquez
Eliana Bohórquez
DPDiego Paredes-Cuervo
Diego Paredes-Cuervo
CACarlos Alberto ARIAS
Carlos Alberto ARIAS
This study assessed the treatment of domestic wastewater to find the optimum vertical flow-constructed wetland (VFCW) configuration under tropical conditions. Eight pilot-scale configurations units were studied to compare between fine sand and medium gravel used as substrate, two feeding frequencies (20 pulses d−1 and 10 pulses d−1), and the presence or absence of tropical plants (Heliconia psittacorum). The results showed that the sand beds were significantly more efficient in the removal of organic matter, ammonia nitrogen, and total suspended solids than gravel beds, presenting average removal rates of 48 and 24 g m−2 d−1 of COD; 35 and 16 g m−2 d−1 of BOD5; 7 and 4 g m−2 d−1 of ; 9 and 0 g m−2 d−1 for sand and gravel, respectively. The oxygen consumption rates were calculated and a value of 65 g m−2 d−1 was obtained for sand beds while for the gravel beds the consumption rate was 30 g m−2 d−1. The assessment of different kinds of nitrogen showed interesting dynamics in the nitrification processes. The presence of H. psittacorum showed positive effects in the total nitrogen (TN) removal. The different loading frequencies applied did not show significant statistical differences in the removal of the tested contaminants. Preliminary results were found in the pathogen removal, where the sand is favorable as the substrate. This work represents the first step in the research of optimum VFWC design and operation parameters for Colombia as well as the use of plants of the genus Heliconia.

1 June 2020 in Science of The Total Environment
Verified
Journal Article
Closed access
CRCarlos A. Ramirez-Vargas
Carlos A. Ramirez-Vargas
CACarlos Alberto ARIAS
Carlos Alberto ARIAS
LZLiang Zhang
Liang Zhang
DPDiego Paredes-Cuervo
Diego Paredes-Cuervo
Hans BrixHans Brix
Hans Brix

18 April 2016 in Ingeniería e Investigación
Verified
Journal Article
Open access
JVJuan Pablo Arrubla Vélez
Juan Pablo Arrubla Vélez
JVJanneth Astrid Cubillos Vargas
Janneth Astrid Cubillos Vargas
CRCarlos A. Ramirez-Vargas
Carlos A. Ramirez-Vargas
JGJhon Alexander Arredondo Gonzalez
Jhon Alexander Arredondo Gonzalez
CACarlos Alberto ARIAS
Carlos Alberto ARIAS
DPDiego Paredes-Cuervo
Diego Paredes-Cuervo
In several countries around the world, Pharmaceutical and Personal Care Products (PPCPs) exist in aquatic environments, a fact that increases the awareness within the scientific community with respect to their possible fate and environment effects. This research presents a preliminary monitoring of use, consumption and presence of PPCPs in wastewater from a treatment plant in a rural area of Pereira (Colombia). Domestic sewage is treated in a septic tank followed by an Up-Flow Anaerobic Filter and its effluent is discharged into the Otún River, upstream of the water intake of the supply system of the city. The compounds monitored in this research included ibuprofen, naproxen, diclofenac, aspirin, ketoprofen, caffeine, galaxolide, tonalide and dihydrojasmonate. An adapted method of multi-residue analysis was used, which is based on solid phase extraction with hydrophilic-lipophilic balance cartridges, and determination by gas chromatography-mass spectrometry. The removal efficiencies demonstrated that the treatment plant could eliminate less than 50% of dihydrojasmonate, diclofenac and galaxolide existing in wastewater; concentration of aspirin, naproxen and tonalide could only be reduced in 15%; and caffeine, ibuprofen and ketoprofen were not removed. Results provided basic information to decide over the necessity of complementary treatments for effluents from systems with the mentioned units.

1 August 2007 in Water Science & Technology
Verified
Journal Article
Closed access
PDF file
DPDiego Paredes-Cuervo
Diego Paredes-Cuervo
PKP. Kuschk
P. Kuschk
FSF. Stange
F. Stange
RMR.A. Müller
R.A. Müller
HKH. Köser
H. Köser
Anaerobic ammonia oxidation (Anammox) has been identified as a new general process-strategy for nitrogen removal in wastewater treatment. In order to evaluate the role and effects of the Anammox process in wetlands, laboratory-scale model experiments were performed with planted fixed bed reactors. A reactor (planted with Juncus effusus) was fed with synthetic wastewater containing 150–200 mg L−1 NH+4 and 75–480 mg L−1 NO−2. Under these operating conditions, the plants were affected by the high ammonia and nitrite concentrations and the nitrogen removal rate fell within the same range of 45–49 mg N d−1 (equivalent to 0.64–0.70 g Nm−2d−1) as already reported by other authors. In order to stimulate the rate of nitrogen conversion, the planted reactor was inoculated with Anammox biomass. As a result, the rate of nitrogen removal was increased 4–5-fold and the toxic effects on the plants also disappeared. The results show that, in principle, subsurface flow wetlands can also function as an “Anammox bioreactor”. However, the design of a complete process for the treatment of waters with a high ammonia load and, in particular, the realisation of simple technical solutions for partial nitrification have still to be developed.

7 July 2022 in Frontiers in Sustainable Cities
Verified
Journal Article
Open access
LMLourdes Montalvo
Lourdes Montalvo
DFDavid Fosca
David Fosca
DPDiego Paredes-Cuervo
Diego Paredes-Cuervo
MAMonica Abarca
Monica Abarca
CSCarlos Hiroo Saito
Carlos Hiroo Saito
EVEdwin Villanueva
Edwin Villanueva
Monitoring air quality is very important in urban areas to alert the citizens about the risks posed by the air they breathe. However, implementing conventional monitoring networks may be unfeasible in developing countries due to its high costs. In addition, it is important for the citizen to have current and future air information in the place where he is, to avoid overexposure. In the present work, we describe a low-cost solution deployed in Lima city that is composed of low-cost IoT stations, Artificial Intelligence models, and a web application that can deliver predicted air quality information in a graphical way (pollution maps). In a series of experiments, we assessed the quality of the temporal and spatial prediction. The error levels were satisfactory when compared to reference methods. Our proposal is a cost-effective solution that can help identify high-risk areas of exposure to airborne pollutants and can be replicated in places where there are no resources to implement reference networks.