Florian Schaff

Dr. Florian Schaff

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 November 2015 in Nature
Verified
Journal Article
Closed access
FSFlorian Schaff
Florian Schaff
MBMartin Bech
Martin Bech
PZPaul Zaslansky
Paul Zaslansky
CJChristoph Jud
Christoph Jud
MLMarianne Liebi
Marianne Liebi
FPFranz Pfeiffer
Franz Pfeiffer

10 January 2018 in European Radiology Experimental
Verified
Journal Article
Open access
PDF file
EBEva-Maria Braig
Eva-Maria Braig
LBLorenz Birnbacher
Lorenz Birnbacher
FSFlorian Schaff
Florian Schaff
LGLukas Gromann
Lukas Gromann
AFAlexander Fingerle
Alexander Fingerle
DMDaniela Muenzel
Daniela Muenzel
Currently, the detection of retained wood is a frequent but challenging task in emergency care. The purpose of this study is to demonstrate improved foreign-body detection with the novel approach of preclinical X-ray dark-field radiography. At a preclinical dark-field x-ray radiography, setup resolution and sensitivity for simultaneous detection of wooden and metallic particles have been evaluated in a phantom study. A clinical setting has been simulated with a formalin fixated human hand where different typical foreign-body materials have been inserted. Signal-to-noise ratios (SNR) have been determined for all test objects. On the phantom, the SNR value for wood in the dark-field channel was strongly improved by a factor 6 compared to conventional radiography and even compared to the SNR of an aluminium structure of the same size in conventional radiography. Splinters of wood < 300 μm in diameter were clearly detected on the dark-field radiography. Dark-field radiography of the formalin-fixated human hand showed a clear signal for wooden particles that could not be identified on conventional radiography. x-ray dark-field radiography enables the simultaneous detection of wooden and metallic particles in the extremities. It has the potential to improve and simplify the current state-of-the-art foreign-body detection.

1 September 2016 in Journal of Structural Biology
Verified
Journal Article
Open access
MTMikael Turunen
Mikael Turunen
JKJørn D. Kaspersen
Jørn D. Kaspersen
UOULF OLSSON
ULF OLSSON
MGManuel Guizar-Sicairos
Manuel Guizar-Sicairos
MBMartin Bech
Martin Bech
HIHanna Isaksson
Hanna Isaksson
The macro- and micro-features of bone can be assessed by using imaging methods. However, nano- and molecular features require more detailed characterization, such as use of e.g., vibrational spectroscopy and X-ray scattering. Nano- and molecular features also affect the mechanical competence of bone tissue. The aim of the present study was to reveal the effects of mineralization and its alterations on the mineral crystal scale, by investigating the spatial variation of molecular composition and mineral crystal structure across the cross-section of femur diaphyses in young rats, and healthy and osteoporotic mature rats (N=5). Fourier transform infrared spectroscopy and scanning small- and wide-angle X-ray scattering (SAXS/WAXS) techniques with high spatial resolution were used at identical locations over the whole cross-section. This allowed quantification of point-by-point information about the spatial distribution of mineral crystal volume. All measured parameters (crystal dimensions, degree of orientation and predominant orientation) varied across the cortex. Specifically, the crystal dimensions were lower in the central cortex than in the endosteal and periosteal regions. Mineral crystal orientation followed the cortical circumference in the periosteal and endosteal regions, but was less well-oriented in the central regions. Central cortex is formed rapidly during development through endochondral ossification. Since rats possess no osteonal remodeling, this bone remains (until old age). Significant linear correlations were observed between the dimensional and organizational parameters, e.g., between crystal length and degree of orientation (R(2)=0.83, p<0.001). Application of SAXS/WAXS provides valuable information on bone nanostructure and its constituents, effects of diseases and, prospectively, mechanical competence.

1 March 2017 in NDT & E International
Verified
Journal Article
Closed access
FPF. Prade
F. Prade
FSFlorian Schaff
Florian Schaff
SSS. Senck
S. Senck
PMPascal Meyer
Pascal Meyer
JMJ. Mohr
J. Mohr
FPF. Pfeiffer
F. Pfeiffer

5 October 2016 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
MWM. Wieczorek
M. Wieczorek
FSFlorian Schaff
Florian Schaff
FPF. Pfeiffer
F. Pfeiffer
TLT. Lasser
T. Lasser
The x-ray dark-field signal measured in grating interferometers is anisotropic, depending on both the beam direction and the grating orientation with respect to the sample. We present a novel general closed-form, continuous forward model of the anisotropic dark-field signal. Furthermore, we derive a discretization using spherical harmonics, leading to a large-scale linear inverse problem. We present first experimental results of a wooden sample, demonstrating marked advantages over previous results, in particular, the resolution of multiple scattering directions in one volume element.

1 June 2015 in Optics Express
Verified
Journal Article
Open access
PDF file
JVJakob Vogel
Jakob Vogel
FSFlorian Schaff
Florian Schaff
AFAndreas Fehringer
Andreas Fehringer
CJChristoph Jud
Christoph Jud
MWMatthias Wieczorek
Matthias Wieczorek
TLTobias Lasser
Tobias Lasser
Quite recently, a method has been presented to reconstruct X-ray scattering tensors from projections obtained in a grating interferometry setup. The original publications present a rather specialised approach, for instance by suggesting a single SART-based solver. In this work, we propose a novel approach to solving the inverse problem, allowing the use of other algorithms than SART (like conjugate gradient), a faster tensor recovery, and an intuitive visualisation. Furthermore, we introduce constraint enforcement for X-ray tensor tomography (cXTT) and demonstrate that this yields visually smoother results in comparison to the state-of-art approach, similar to regularisation.