This paper proposes a new sensor placement approach for leak location in water distribution networks (WDNs). The sensor placement problem is formulated as an integer optimization problem. The optimization criterion consists in minimizing the number of non-isolable leaks according to the isolability criteria introduced. Because of the large size and non-linear integer nature of the resulting optimization problem, genetic algorithms (GAs) are used as the solution approach. The obtained results are compared with a semi-exhaustive search method with higher computational effort, proving that GA allows one to find near-optimal solutions with less computational load. Moreover, three ways of increasing the robustness of the GA-based sensor placement method have been proposed using a time horizon analysis, a distance-based scoring and considering different leaks sizes. A great advantage of the proposed methodology is that it does not depend on the isolation method chosen by the user, as long as it is based on leak sensitivity analysis. Experiments in two networks allow us to evaluate the performance of the proposed approach.
This paper presents a literature review on optimal control techniques for energy management and control of microgrids. A classifi- cation of references linked with the design and development of optimal energy management systems (EMS) is made, considering mainly the objective functions to be solved and also the optimization techniques used for solving optimal control problems (OCPs) related with reliable operations of microgrids. A hierarchical control architecture for the development of EMS is the most com- monly found in literature, which implies the necessity of a telecommunications infrastructure to communicate a distributed control layer with an upper layer, where the optimization of the microgrid operation is done. Typically, this layer is developed at an entity called microgrid central controller (MGCC). A general architecture for optimal EMS is provided and analyzed in detail, as well as its future perspectives
17 May 2016 in IEEE Transactions on Industrial Informatics
This paper presents a methodology on the design of an optimal predictive control scheme applied to an islanded microgrid. The controller manages the batteries energy and performs a centralized load shedding strategy to balance the load and generation within the microgrid, and to keep the stability of the voltage magnitude. A nonlinear model predictive control (NMPC) algorithm is used for processing a data set composed of the batteries state of charge, the distributed energy resources (DERs) active power generation, and the forecasted load. The NMPC identifies upcoming active power unbalances and initiates automated load shedding over noncritical loads. The control strategy is tested in a medium voltage distribution system with DERs. This control strategy is assisted by a distribution monitoring system, which performs real-time monitoring of the active power generated by the DERs and the current load demand at each node of the microgrid. Significant performance improvement is achieved with the use of this control strategy over tested cases without its use. The balance between the power generated by the DERs and the load demand is maintained, while the voltage magnitude is kept within the maximum variation margin of ±5% recommended by the standard ANSI C84.1-1989.
In this paper, we propose a new approach for model-based leak detection and location in water distribution networks (WDN), which considers an extended time-horizon analysis of pressure sensitivities. Five different ways of using the leak sensitivity matrix to isolate the leaks are described and compared. The first method is based on the binarization approach. The second, third and fourth methods are based on the comparison of the measured pressure vectors with the leak sensitivity matrix using different metrics: correlation, angle between vectors and Euclidean distance, respectively. The fifth method is based on the least square optimization method. The performance of these methods is compared when applied to two academic small networks (Hanoi and Quebra) widely used in the literature. Finally, the three methods with better performance are applied to a district metering area of the Barcelona WDN using real data.
In this paper, a sensor placement approach to improve the leak location in waterdistribution networks is proposed when the leak signature space (LSS) method is used.The sensor placement problem is formulated as an integer optimization problem where thecriterion to be minimized is the number of overlapping signature domains computed fromthe original LSS representation. First, a semi-exhaustive search approach based on a lazyevaluation mechanism ensures optimal placement in the case of low complexity scenarios.For more complex cases, a stochastic optimization process is proposed, based on eitherthe genetic algorithms (GAs) or particle swarm optimization (PSO). Experiments on twodifferent networks are used to evaluate the performance of the resolution methods, as well asthe efficiency achieved in the leak location when using the sensor placement results.
This paper proposes a reliable fault-tolerant model predictive control applied to drinking water transport networks. After a fault has occurred, the predictive controller should be redesigned to cope with the fault effect. Before starting to apply the fault-tolerant control strategy, it should be evaluated whether the predictive controller will be able to continue operating after the fault appearance. This is done by means of a structural analysis to determine loss of controllability after the fault complemented with feasibility analysis of the optimization problem related to the predictive controller design, so as to consider the fault effect in actuator constraints. Moreover, by evaluating the admissibility of the different actuator-fault configurations, critical actuators regarding fault tolerance can be identified considering structural, feasibility, performance and reliability analyses. On the other hand, the proposed approach allows a degradation analysis of the system to be performed. As a result of these analyses, the predictive controller design can be modified by adapting constraints such that the best achievable performance with some pre-established level of reliability will be achieved. The proposed approach is tested on the Barcelona drinking water transport network.Postprint (author's final draft