In view of problems such as the poor control effect of combined sewage pollution caused by traditional intercepting weir and the limited extension of the urban drainage model, which needs a large amount of basic data, this paper not only studied the characteristics of mixed-flow pollution via the urban drainage model but also simulated and optimized 6 interception control strategies and proposed a water quality interception strategy based on the pollution concentration of combined sewage. The results showed that, compared with the traditional interception weir, the interception control strategy of rainwater discharge based on the mixed pipe network model can obviously improve the control rate of various pollutants and reduce the interception amount required for pollution control. Through optimization of the interception based on water quality control by the combination of chemical oxygen demand (COD) and NH4-N, the interception rate was improved by 10.9% to 56.1% in contrast to the traditional interception weir and the closure water volume was reduced by 1432–6154 m3, which effectively improved the reliability and economy of the interception.
The combined sewer overflows (CSO) pollution has caused many serious environmental problems, which has aroused a worldwide concern. Traditional interception-storage measures, which exhibit the disadvantages of the larger storage tank volume and the low concentration, cannot efficiently control the CSO pollution. To solve this problem, a water quality-based double-gate control strategy based on the pollution based real-time control (PBRTC) rule was proposed, and the chemical oxygen demand (COD) concentration was taken as the control index. A case study was carried out in Fuzhou, China as an example, in which the hydraulic and water quality model were constructed to evaluate two schemes. According to the results, compared to the traditional scheme, the double-gate scheme can not only reduce the storage tank volume by 1515 m3, but also increase the average COD interception rate by 1.84 times, thus ensuring the effective and stable operation of the facility. Furthermore, the traditional scheme and the double-gate scheme were evaluated under design rainfall beyond the design return period, which confirmed the high performance of the double-gate scheme in controlling CSO pollution.
This study evaluated the effectiveness of five commercial substrates (zeolite, volcanic rock, gravel, magic rack, and ceramic pellets) in removing nitrogen (N) and phosphorus (P) from urban river systems using constructed wetlands. By employing X-ray CT and NGS technologies, we analyzed the physical structure of the substrates and the microbial communities they harbor. The results indicated that volcanic rock and ceramic pellets, due to their high porosity and specific surface area, performed exceptionally well in nitrogen and phosphorus removal. Specifically, the microbial systems with these two substrates achieved ammonia nitrogen removal rates of 89.86% and 88.45%, total nitrogen removal rates of 78.78% and 74.97%, and total phosphorus removal rates of 92.67% and 80.82%, respectively, within a 7-day period. Furthermore, the microbial communities on volcanic rock and ceramic pellets were more diverse, which correlated with their high pollutant removal efficiency. The study further elucidated the synergistic role of substrate characteristics and microbial community structure and function in nitrogen and phosphorus removal, enhancing the understanding of the purification mechanisms in constructed wetlands. These findings provide a scientific basis for the ecological restoration of urban rivers and are significant for improving the quality of urban water environments.