Farnaz Matin

Dr. Farnaz Matin

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 December 2021 in Biomolecules
Verified
Journal Article
Open access
PDF file
Ziwen GaoZiwen Gao
Ziwen Gao
JSJana Schwieger
Jana Schwieger
FMFarnaz Matin
Farnaz Matin
PBPeter Behrens
Peter Behrens
TLThomas Lenarz
Thomas Lenarz
Verena ScheperVerena Scheper
Verena Scheper
Dexamethasone is widely used in preclinical studies and clinical trials to treat inner ear disorders. The results of those studies vary widely, maybe due to the different dexamethasone formulations used. Laboratory (lab) and medical grade (med) dexamethasone (DEX, C22H29FO5) and dexamethasone dihydrogen phosphate-disodium (DPS, C22H28FNa2O8P) were investigated for biocompatibility and bio-efficacy in vitro. The biocompatibility of each dexamethasone formulation in concentrations from 0.03 to 10,000 µM was evaluated using an MTT assay. The concentrations resulting in the highest cell viability were selected to perform a bio-efficiency test using a TNFα-reduction assay. All dexamethasone formulations up to 900 µM are biocompatible in vitro. DPS-lab becomes toxic at 1000 µM and DPS-med at 2000 µM, while DEX-lab and DEX-med become toxic at 4000 µM. Bio-efficacy was evaluated for DEX-lab and DPS-med at 300 µM, for DEX-med at 60 µM, and DPS-lab at 150 µM, resulting in significantly reduced expression of TNFα, with DPS-lab having the highest effect. Different dexamethasone formulations need to be applied in different concentration ranges to be biocompatible. The concentration to be applied in future studies should carefully be chosen based on the respective dexamethasone form, application route and duration to ensure biocompatibility and bio-efficacy.

19 April 2023 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
VDVanessa Domsta
Vanessa Domsta
CHChristin Hänsch
Christin Hänsch
SLStine Lenz
Stine Lenz
Ziwen GaoZiwen Gao
Ziwen Gao
FMFarnaz Matin
Farnaz Matin
ASAnne Seidlitz
Anne Seidlitz
The local treatment of diseases by drug-eluting implants is a promising tool to enable successful therapy under potentially reduced systemic side effects. Especially, the highly flexible manufacturing technique of 3D printing provides the opportunity for the individualization of implant shapes adapted to the patient-specific anatomy. It can be assumed that variations in shape can strongly affect the released amounts of drug per time. This influence was investigated by performing drug release studies with model implants of different dimensions. For this purpose, bilayered model implants in a simplified geometrical shape in form of bilayered hollow cylinders were developed. The drug-loaded abluminal part consisted of a suitable polymer ratio of Eudragit® RS and RL, while the drug-free luminal part composed of polylactic acid served as a diffusion barrier. Implants with different heights and wall thicknesses were produced using an optimized 3D printing process, and drug release was determined in vitro. The area-to-volume ratio was identified as an important parameter influencing the fractional drug release from the implants. Based on the obtained results drug release from 3D printed implants with individual shapes exemplarily adapted to the frontal neo-ostial anatomy of three different patients was predicted and also tested in an independent set of experiments. The similarity of predicted and tested release profiles indicates the predictability of drug release from individualized implants for this particular drug-eluting system and could possibly facilitate the estimation of the performance of customized implants independent of individual in vitro testing of each implant geometry.

26 April 2021 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
FMFarnaz Matin
Farnaz Matin
Ziwen GaoZiwen Gao
Ziwen Gao
FRFelix Repp
Felix Repp
SJSamuel John
Samuel John
TLThomas Lenarz
Thomas Lenarz
Verena ScheperVerena Scheper
Verena Scheper
Modern therapy of inner ear disorders is increasingly shifting to local drug delivery using a growing number of pharmaceuticals. Access to the inner ear is usually made via the round window membrane (RWM), located in the bony round window niche (RWN). We hypothesize that the individual shape and size of the RWN have to be taken into account for safe reliable and controlled drug delivery. Therefore, we investigated the anatomy and its variations. Cone beam computed tomography (CBCT) images of 50 patients were analyzed. Based on the reconstructed 3D volumes, individual anatomies of the RWN, RWM, and bony overhang were determined by segmentation using 3D SlicerTM with a custom build plug-in. A large individual anatomical variability of the RWN with a mean volume of 4.54 mm3 (min 2.28 mm3, max 6.64 mm3) was measured. The area of the RWM ranged from 1.30 to 4.39 mm2 (mean: 2.93 mm2). The bony overhang had a mean length of 0.56 mm (min 0.04 mm, max 1.24 mm) and the shape was individually very different. Our data suggest that there is a potential for individually designed and additively manufactured RWN implants due to large differences in the volume and shape of the RWN.

11 June 2022 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
FMFarnaz Matin
Farnaz Matin
Ziwen GaoZiwen Gao
Ziwen Gao
JSJana Schwieger
Jana Schwieger
MUMartin Ulbricht
Martin Ulbricht
VDVanessa Domsta
Vanessa Domsta
Verena ScheperVerena Scheper
Verena Scheper
Postoperative restenosis in patients with external ear canal (EEC) atresia or stenosis is a common complication following canaloplasty. Our aim in this study was to explore the feasibility of using a three dimensionally (3D)-printed, patient-individualized, drug ((dexamethasone (DEX)), and ciprofloxacin (cipro))-releasing external ear canal implant (EECI) as a postoperative stent after canaloplasty. We designed and pre-clinically tested this novel implant for drug release (by high-performance liquid chromatography), biocompatibility (by the MTT (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) assay), bio-efficacy (by the TNF-α (tumor necrosis factor-alpha)-reduction test (DEX) and inhibition zone test (for cipro)), and microbial contamination (formation of turbidity or sediments in culture medium). The EECI was implanted for the first time to one patient with a history of congenital EEC atresia and state after three canaloplasties due to EEC restenosis. The preclinical tests revealed no cytotoxic effect of the used materials; an antibacterial effect was verified against the bacteria Staphylococcus aureus and Pseudomonas aeruginosa, and the tested UV-irradiated EECI showed no microbiological contamination. Based on the test results, the combination of silicone with 1% DEX and 0.3% cipro was chosen to treat the patient. The EECI was implantable into the EEC; the postoperative follow-up visits revealed no otogenic symptoms or infections and the EECI was explanted three months postoperatively. Even at 12 months postoperatively, the EEC showed good epithelialization and patency. Here, we report the first ever clinical application of an individualized, drug-releasing, mechanically flexible implant and suggest that our novel EECI represents a safe and effective method for postoperatively stenting the reconstructed EEC.

22 September 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
FMFarnaz Matin
Farnaz Matin
EAEralp-Niyazi Artukarslan
Eralp-Niyazi Artukarslan
AIAngelika Illg
Angelika Illg
ALAnke Lesinski-Schiedat
Anke Lesinski-Schiedat
TLThomas Lenarz
Thomas Lenarz
MSMarie Charlot Suhling
Marie Charlot Suhling
This retrospective study aimed to investigate the range of hearing levels in a cochlear implant (CI) elderly population receiving electric-acoustic-stimulation (EAS) or electric-stimulation (ES) alone. The investigation evaluates the degree of hearing preservation (HP) and the speech comprehension resulting from EAS or ES-only to identify audiometric factors that predict adequate EAS and ES use. We analyzed the pure tone audiometry and speech perception in quiet and noise preoperatively and 12-months after activation of 89 elderly adults (age of 65 years old or older), yielding in total 97 CIs. Thirty-two (33.1%) patients were potential EAS candidates preoperatively, of which 18 patients used EAS at the time of first fitting and the other 14 patients continued to use their residual hearing for EAS at 12-months. Post-treatment, patients with EAS system and ES-only users’ with longer electrodes showed better results in monosyllable word scores in quiet than ES-only users with shorter electrodes. A similar trend was revealed for the speech recognition in noise. Patients with an EAS system benefit from maintaining their natural residual hearing. Nevertheless, strict preoperative patient selection is warranted particularly in elderly patients, in whom the hearing thresholds for EAS indication differ slightly from that in younger adults.

17 December 2020 in Life
Verified
Journal Article
Open access
PDF file
Ziwen GaoZiwen Gao
Ziwen Gao
FMFarnaz Matin
Farnaz Matin
CWConstantin Weber
Constantin Weber
SJSamuel John
Samuel John
TLThomas Lenarz
Thomas Lenarz
Verena ScheperVerena Scheper
Verena Scheper
Chronic rhinosinusitis (CRS) is a common disease in the general population that is increasing in incidence and prevalence, severely affecting patients’ quality of life. Medical treatment for CRS includes self-management techniques, topical and oral medical treatments, and functional endoscopic sinus surgery (FESS). FESS is a standard procedure to restore sinus ventilation and drainage by physically enlarging the inflamed sinus passageways. Nasal drug-releasing stents are implanted to keep the surgically expanded aperture to the sinus frontalis open. The outcome of such an intervention is highly variable. We defined the anatomical structures which should be removed, along with ‘no-go areas’ which need to be preserved during FESS. Based on these definitions, we used cone beam computed tomography (CBCT) images to measure the dimensions of the frontal neo-ostium in 22 patients. We demonstrate anatomical variability in the volume and diameter of the frontal sinus recess after surgery. This variability could be the cause of therapy failure of drug-eluting implants after FESS in some patients. Implants individually made to fit a given patient’s postsurgical anatomy may improve the therapeutic outcome.