Vitalii Valentinovich Kolobov

Vitalii Valentinovich Kolobov

Auto-generated profile, based on publicly available information

Vitalii Valentinovich Kolobov


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 September 2023 in Solar-Terrestrial Physics
Verified
Journal Article
Open access
PDF file
VSVasily Nikolaevich Selivanov
Vasily Nikolaevich Selivanov
TATatyana Aksenovich
Tatyana Aksenovich
VBVladislav Bilin
Vladislav Bilin
VKVitaliy Kolobov
Vitaliy Kolobov
YSYaroslav Saharov
Yaroslav Saharov
Database containing the results of measurements of geomagnetically induced currents (GIC) for the period of 2011 to 2022 in transformer neutrals at three 330 kV substations of the main power transmission lines “Northern Transit” passing through the territory of the Republic of Karelia, Murmansk and Leningrad regions has been created and is publicly available. The GIC value depends on the geoelectric field magnitude in the Earth surface, on the relative position of the substations to which the power transmission lines are connected, and on the resistance of electrical network elements. Important factors are the electrical network branching, which determines paths of induced current spreading, and the network topology at the time of monitoring data acquisition. We describe the structure and principles of functioning of the Russian unique regional monitoring system of geomagnetically induced currents in the electrical network. We demonstrate the features of the data contained in the GIC database, which must be taken into account when processing and analyzing the data. Examples of using the GIC database for energy and geophysical studies are given. The work performed on the organization of continuous monitoring of GIC at substations of the main power transmission line in the Arctic zone has no analogues in the Russian Federation and provides extensive original material that allows us to study geomagnetic disturbances and their impact on electrical networks. The database is available at [http://gic.en51.ru]

1 January 2012 in Seismic Instruments
Verified
Journal Article
Closed access
PDF file
VKV. V. Kolobov
V. V. Kolobov
DKD. N. Kuklin
D. N. Kuklin
ASA. N. Shevtsov
A. N. Shevtsov
AZA. A. Zhamaletdinov
A. A. Zhamaletdinov

29 September 2023 in Solar-Terrestrial Physics
Verified
Journal Article
Open access
PDF file
VSVasily Nikolaevich Selivanov
Vasily Nikolaevich Selivanov
TATatyana Aksenovich
Tatyana Aksenovich
VBVladislav Bilin
Vladislav Bilin
VKVitaliy Kolobov
Vitaliy Kolobov
YSYaroslav Saharov
Yaroslav Saharov
Database containing the results of measurements of geomagnetically induced currents (GIC) for the period of 2011 to 2022 in transformer neutrals at three 330 kV substations of the main power transmission lines “Northern Transit” passing through the territory of the Republic of Karelia, Murmansk and Leningrad regions has been created and is publicly available. The GIC value depends on the geoelectric field magnitude in the Earth surface, on the relative position of the substations to which the power transmission lines are connected, and on the resistance of electrical network elements. Important factors are the electrical network branching, which determines paths of induced current spreading, and the network topology at the time of monitoring data acquisition. We describe the structure and principles of functioning of the Russian unique regional monitoring system of geomagnetically induced currents in the electrical network. We demonstrate the features of the data contained in the GIC database, which must be taken into account when processing and analyzing the data. Examples of using the GIC database for energy and geophysical studies are given. The work performed on the organization of continuous monitoring of GIC at substations of the main power transmission line in the Arctic zone has no analogues in the Russian Federation and provides extensive original material that allows us to study geomagnetic disturbances and their impact on electrical networks. The database is available at [http://gic.en51.ru].

1 January 2013 in Seismic Instruments
Verified
Journal Article
Closed access
PDF file
MBM. B. Barannik
M. B. Barannik
VKV. V. Kolobov
V. V. Kolobov
ASA. N. Shevtsov
A. N. Shevtsov
AZAbdulkhai Zhamaletdinov
Abdulkhai Zhamaletdinov
A generating-measuring complex of directional operation, which allows investigating seismically dangerous zone of stressedly-deformed state of rock, ore zones, and fracture zones in the directions which are the most sensitive from the standpoint of the aim in view, namely along and across the strike axes of the object of interest, is developed. The complex includes the Energy-2M directional operation generator and a portable high-sensitivity KVVN-7m measuring station that allows performing frequency probing with controllable sources and sounding in the field of natural electromagnetic field variations during one cycle. The generator includes a system of independent phase and amplitude adjustment of the current at the output of the Energy-2M generator inverter along two channels. A circuit of programmed generator current supply to two mutually orthogonal antenna arrays (long grounded lines) and a system of precision control over the current parameters in each arm is developed. The generator allows generating a programmed current with circular or elliptical field polarization in the vicinity of the object under study in the specified direction in the frequency range from 1 to 2000 Hz. The Energy-2M generator is mounted on board a ZIL-131 motor vehicle and fed by two PN-72 generators 15 kW each. The KVVN-7 digital measuring station has been completely modified. Moreover, all out-of-date elements have been replaced by modern operational amplifiers characterized by extremely low internal noises, which do not exceed unities or tenths of nV/Hz0.5. The generating complex is equipped with a system for control, regulation, protection, and automation (SCRPA) based on GPS time synchronization. Thermostatting of the unit for clock frequency and reference voltage is provided. All these measures allowed reaching the accuracy of synchronization over the absolute time not worse than 2 × 10−4 s, and frequency stability of the generator signal not worse than 10−7 Hz.

26 June 2025 in Solar-Terrestrial Physics
Verified
Journal Article
Open access
PDF file
VPVyacheslav A. Pilipenko
Vyacheslav A. Pilipenko
EEElena Ermakova
Elena Ermakova
APAlexander Potapov
Alexander Potapov
RMRoman Marchuk
Roman Marchuk
VKVitaliy Kolobov
Vitaliy Kolobov
EDEldar Dmitriev
Eldar Dmitriev
In July–August 2024 on the Kola Peninsula, the FENICS-2024 experiment was conducted to generate artificial electromagnetic signals at night, using two power transmission lines as a horizontal radiating antenna. The generator frequency varied discretely from session to session from 1 to 194 Hz with current amplitude from ~150 A at low frequencies to ~40 A at high frequencies. The paper presents the results of the first stage of the experiment when the power transmission line Vykhodnoy—Olenegorsk with a distance between earth electrodes of substances L=84 km was utilized as a radiating antenna. Magnetic stations, located from ~1200 to ~2100 km from the nodal substation, recorded signals with frequencies from 1 to 9 Hz with ~0.3–~6.0 fT/A amplitudes normalized to the emitter current. The observations have shown the promise of the new type of active experiments on creating a probing signal for magnetotelluric sounding over a large area. The observation results will be compared with theoretical models in the subsequent work.

23 November 2021 in Instruments and Experimental Techniques
Verified
Journal Article
Closed access
PDF file
VKV. V. Kolobov
V. V. Kolobov
MBM. B. Barannik
M. B. Barannik
A digitally controlled high-precision low-noise high-voltage source is described. A push–pull parallel resonant voltage converter with a constant switching frequency of 110 kHz is used in the source. The high-voltage source is adjusted by changing the output voltage of a linear voltage regulator that feeds the resonant converter. An algorithm for controlling the converter switches that makes it possible to implement a mode of supplying the parallel circuit of the converter from the voltage source is proposed. An automatic frequency control system ensures the temperature stability of the converter operating mode. An active ripple filter was designed. Its main feature is the application of a compensating voltage between the common bus of the source and the low-potential output of the voltage multiplier. This solution made it possible to construct the filter based on one low-voltage op-amp, which is simultaneously used as an error signal amplifier of the source control loop. As a result of applying the active filter, the output noise and ripple peak-to-peak amplitude at frequencies higher than 10 Hz does not exceed 3.3 mV. The peak-to-peak noise in the frequency range of 0.1–10 Hz is below 3.5 mV and is determined by the 1/f noise level of the used voltage reference. The developed high voltage source is used in the ion source power supply of the mass-spectrometry system for isotope analysis of noble gases and has the following specifications: the output-voltage control range is 0–5500 V with a step of 84 mV; the maximum load current is 1 mA; and the overall output voltage instability is no more than 50 ppm/h in the operating temperature range of 20–50°C.