Tatyana Aksenovich

Ms. Tatyana Aksenovich

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 September 2023 in Solar-Terrestrial Physics
Verified
Journal Article
Open access
PDF file
VSVasily Nikolaevich Selivanov
Vasily Nikolaevich Selivanov
TATatyana Aksenovich
Tatyana Aksenovich
VBVladislav Bilin
Vladislav Bilin
VKVitaliy Kolobov
Vitaliy Kolobov
YSYaroslav Saharov
Yaroslav Saharov
Database containing the results of measurements of geomagnetically induced currents (GIC) for the period of 2011 to 2022 in transformer neutrals at three 330 kV substations of the main power transmission lines “Northern Transit” passing through the territory of the Republic of Karelia, Murmansk and Leningrad regions has been created and is publicly available. The GIC value depends on the geoelectric field magnitude in the Earth surface, on the relative position of the substations to which the power transmission lines are connected, and on the resistance of electrical network elements. Important factors are the electrical network branching, which determines paths of induced current spreading, and the network topology at the time of monitoring data acquisition. We describe the structure and principles of functioning of the Russian unique regional monitoring system of geomagnetically induced currents in the electrical network. We demonstrate the features of the data contained in the GIC database, which must be taken into account when processing and analyzing the data. Examples of using the GIC database for energy and geophysical studies are given. The work performed on the organization of continuous monitoring of GIC at substations of the main power transmission line in the Arctic zone has no analogues in the Russian Federation and provides extensive original material that allows us to study geomagnetic disturbances and their impact on electrical networks. The database is available at [http://gic.en51.ru]

29 September 2023 in Solar-Terrestrial Physics
Verified
Journal Article
Open access
PDF file
VSVasily Nikolaevich Selivanov
Vasily Nikolaevich Selivanov
TATatyana Aksenovich
Tatyana Aksenovich
VBVladislav Bilin
Vladislav Bilin
VKVitaliy Kolobov
Vitaliy Kolobov
YSYaroslav Saharov
Yaroslav Saharov
Database containing the results of measurements of geomagnetically induced currents (GIC) for the period of 2011 to 2022 in transformer neutrals at three 330 kV substations of the main power transmission lines “Northern Transit” passing through the territory of the Republic of Karelia, Murmansk and Leningrad regions has been created and is publicly available. The GIC value depends on the geoelectric field magnitude in the Earth surface, on the relative position of the substations to which the power transmission lines are connected, and on the resistance of electrical network elements. Important factors are the electrical network branching, which determines paths of induced current spreading, and the network topology at the time of monitoring data acquisition. We describe the structure and principles of functioning of the Russian unique regional monitoring system of geomagnetically induced currents in the electrical network. We demonstrate the features of the data contained in the GIC database, which must be taken into account when processing and analyzing the data. Examples of using the GIC database for energy and geophysical studies are given. The work performed on the organization of continuous monitoring of GIC at substations of the main power transmission line in the Arctic zone has no analogues in the Russian Federation and provides extensive original material that allows us to study geomagnetic disturbances and their impact on electrical networks. The database is available at [http://gic.en51.ru].

31 December 2022 in Russian Journal of Earth Sciences
Verified
Journal Article
Open access
PDF file
TATatyana Aksenovich
Tatyana Aksenovich
VBVladislav Bilin
Vladislav Bilin
YSYaroslav Sakharov
Yaroslav Sakharov
VSVasily Nikolaevich Selivanov
Vasily Nikolaevich Selivanov
The main problem of electric utilities around the world is to ensure continuous power supply to consumers. One of the causes of power outages and blackouts can be geomagnetic storms during periods of the increased solar activity. They arouse geomagnetically induced currents (GICs) flowing in the long-distance high-voltage power grids on Earth’s surface. The history of this phenomenon investigation shows that GICs during strong geomagnetic storms had led to blackouts in certain regions of Canada, Sweden and the USA. To study these phenomena and assess the risks of such accidents for the regional system, a GICs registration system in 330 kV autotransformers neutrals of the Kola-Karelian power transit was developed in northwestern Russia. During 11 years of monitoring numerous cases of the flow of high values of quasi-dc currents with different time durations, induced by variations of the geomagnetic field, have been registered. In order to analyze the currents a wavelet transform was chosen, since this method allows to define not only the frequency composition but also changes in spectral characteristics over time, which is significant in the study of GIC. The paper presents a discussion of GIC scalograms obtained for four events of Solar Cycle 24: 13-14 November 2012, 17-18 March 2015, 7-8 September 2015 and 7-8 September 2017. The analysis showed that the characteristic duration of the peak of the considered GICs is from 4.6 to 11.1 min.

20 January 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
TATatyana Aksenovich
Tatyana Aksenovich
VSVasily Nikolaevich Selivanov
Vasily Nikolaevich Selivanov
During geomagnetic storms, which are a result of solar wind’s interaction with the Earth’s magnetosphere, geomagnetically induced currents (GICs) begin to flow in the long, high-voltage electrical networks on the Earth’s surface. It causes a number of negative phenomena that affect the normal operation of the entire electric power system. To investigate the nature of the phenomenon and its effects on transformers, a GIC monitoring system was created in 2011. The system consists of devices that are installed in the neutrals of autotransformers at five substations of the Kola–Karelian power transit in northwestern Russia. Considering the significant amount of data accumulated over 12 years of operating the GIC monitoring system, manual analysis becomes impractical. To analyze the constantly growing volume of recorded data effectively, a method for the automatic classification of GICs in autotransformer neutrals was proposed. The method is based on a continuous wavelet transform of the neutral current data combined with a convolutional neural network (CNN) to classify the obtained scalogram images. The classifier’s performance is evaluated using accuracy and binary cross-entropy loss metrics. As the result of comparing four CNN architectures, a model that showed high GIC classification performance on the validation set was chosen as the final model. The proposed CNN model, in addition to the main layers, includes pre-processing layers and a dropout layer.

20 March 2025 in Vestnik MEI
Verified
Journal Article
Closed access
PDF file
TATatyana Aksenovich
Tatyana Aksenovich
The main objective pursued by electric power utilities around the world is to provide uninterrupted power supply to consumers. Magnetic storms caused by increased solar activity can cause emergency power outages. During magnetic storms, geomagnetically induced currents (GIC) begin to flow in extended power grids on the Earth’s surface. They, in turn, become the source of a number of negative phenomena that affect normal operation of the entire electric power system. The history of studying this phenomenon shows that the GICs emerged during strong geomagnetic storms led to blackouts in certain regions of Canada, Sweden, and the United States. To study these phenomena and assess the risks of such accidents for the regional system, a system for recording GICs in the neutrals of 330 kV autotransformers used in the Kola-Karelian power transit system was developed in the northwestern part of Russia. For 13 years of continuous monitoring, numerous cases have been recorded, in which quite high quasi DC currents of different durations induced by geomagnetic field variations had emerged. For analyzing the currents, a wavelet transform was chosen, because this method makes it possible to define not only the frequency composition, but also changes in spectral characteristics with time, which is significant in the study of GIC. The GIC scalograms obtained for four events of Solar Cycle 24: 13-14 November 2012, 17-18 March 2015, 7-8 September 2015, and 7-8 September 2017 are analyzed. The analysis results have shown that the characteristic duration of the peaks of the considered GICs was from 4.6 to 11.1 min. Основная задача электроснабжающих компаний по всему миру — бесперебойное питание потребителей. Магнитные бури, вызванные возросшей солнечной активностью, могут служить причиной аварийного отключения электроэнергии. Во время магнитных бурь в протяженных электрических сетях на поверхности Земли начинают протекать геоиндуцированные токи (ГИТ). Они, в свою очередь, становятся источником целого ряда негативных явлений, влияющих на нормальную работу всей электроэнергетической системы. История изучения этого явления показывает, что ГИТ во время сильных магнитных бурь приводили к нарушению электроснабжения отдельных регионов Канады, Швеции и США. С целью изучения этого явления и оценки рисков таких аварий для региональной системы на северо-западе России была создана система регистрации ГИТ в нейтралях автотрансформаторов 330 кВ Кольско-Карельского транзита. За 13 лет непрерывного мониторинга зафиксированы многочисленные случаи протекания высоких значений квазипостоянных токов разной длительности, индуцированных изменением геомагнитного поля. Для анализа токов выбрано вейвлет-преобразование, поскольку этот метод позволяет фиксировать не только состав частот, но и изменение спектральных характеристик во времени, что является немаловажным при изучении ГИТ. Представлен анализ полученных скейлограмм ГИТ для четырех событий 24-го солнечного цикла: 13 — 14 ноября 2012 г., 17 — 18 марта 2015 г., 7 — 8 сентября 2015 г. и 7 — 8 сентября 2017 г. Анализ показал, что характерная длительность пиков рассмотренных ГИТ составила от 4,6 до 11,1 мин.

12 December 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
TATatyana Aksenovich
Tatyana Aksenovich
VSVasily Nikolaevich Selivanov
Vasily Nikolaevich Selivanov
During geomagnetic storms, which are a result of solar wind interaction with the Earth’s magnetosphere, geomagnetically induced currents (GICs) begin to flow in the long-distance high-voltage power grids on the Earth’s surface. It causes a number of negative phenomena that affect the normal operation of the entire electric power system. To investigate the nature of the phenomenon and its possible effects on transformers, a GIC monitoring system was created in 2011, the devices of which were installed at five substations of the Kola-Karelian power transit in northwestern Russia. Over 12 years of operating the system a large amount of data has been accumulated, which cannot be analyzed manually within a reasonable amount of time. To analyze the constantly growing volume of recorded data effectively, a method for automatic classification of GIC in autotransformer neutral was proposed. The method is based on a continuous wavelet transform of the neutral current data combined with a convolutional neural network (CNN) to classify the obtained scalogram images. As the result of comparing four CNNs with different architectures, a model that showed excellent GIC classification performance on the validation set (100.00% accuracy and loss of 0.0115) was chosen.