Yula Serpanos

Dr. Yula Serpanos

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 December 2018 in American Journal of Audiology
Verified
Journal Article
Closed access
PDF file
JBJessica Barczik
Jessica Barczik
YSYula Serpanos
Yula Serpanos
Purpose: The purpose of this study is to evaluate smartphone-based self-hearing test applications (apps) for accuracy in threshold assessment and validity in screening for hearing loss across frequencies and earphone transducer styles. Method: Twenty-two adult participants (10 = normal hearing ; 12 = sensorineural hearing loss ; n = 44 ears) underwent conventional audiometry and performed 6 self-administered hearing tests using two iPhone-based apps (App 1 = uHear [Version 2.0.2, Unitron]; App 2 = uHearingTest [Version 1.0.3, WooFu Tech, LLC.]) each with 3 different transducers (earbud earphones, supra-aural headphones, circumaural headphones). Hearing sensitivity results using the smartphone apps across frequencies and transducers were compared with conventional audiometry. Results: Differences in accuracy were revealed between the hearing test apps across frequencies and earphone styles. The uHear app using the iPhone standard EarPod earbud earphones was accurate to conventional thresholds ( p > .002 with Bonferroni correction) at 1000, 2000, 4000, and 6000 Hz and found valid (81%–100% sensitivity, specificity, positive and negative predictive values) for screening mild or greater hearing loss (> 25 dB HL) at 500, 1000, 2000, 4000, and 6000 Hz. The uHearingTest app was accurate in threshold assessment and determined valid for screening mild or greater hearing loss (> 25 dB HL) using supra-aural headphones at 2000, 4000, and 8000 Hz. Conclusions: Self-hearing test apps can be accurate in hearing threshold assessment and screening for mild or greater hearing loss (> 25 dB HL) when using appropriate transducers. To ensure accuracy, manufacturers should specify earphone model instructions to users of smartphone-based self-hearing test apps.

1 June 2007 in American Journal of Audiology
Verified
Journal Article
Closed access
PDF file
YSYula Serpanos
Yula Serpanos
FJFredi Jarmel
Fredi Jarmel
Purpose: This investigation reports on quantitative and qualitative follow-up information obtained from a preschool audiologic screening program covering a 10-year period (1995 to 2004).Method: The audiologic screening consisted of a hearing (pure tone) and tympanometry screening. A total of 34,979 children, 3 to 5 years of age, were screened.Results: Eighteen percent (6,337) of the children were referred for further hearing and/or medical ear evaluation. Of 1,421 follow-up responses received, 93% complied with the follow-up recommendations while 7% did not. Of 1,316 children in the follow-up group, outer and/or middle ear disorder in one or both ears was medically confirmed for 37%. Unilateral or bilateral hearing loss was diagnosed in 18% as conductive (12%), sensorineural (1%), mixed (0.4%), or unspecified (5%). Overall, hearing loss and/or otologic disorder was confirmed in 49% of the follow-up group, suggesting a prevalence of 1.8% in a preschool-age population. A small (n= 32) sample of unsolicited comments indicated that physicians most influenced noncompliance with hearing evaluation follow-up.Conclusions: The quantitative hearing and otologic follow-up outcome data affirm the importance of audiologic screening in the preschool population. Qualitative data suggest that some physicians may not be advocating appropriate screening follow-up services.

21 November 2018 in American Journal of Speech-Language Pathology
Verified
Journal Article
Closed access
PDF file
YSYula Serpanos
Yula Serpanos
BRBrittany Renne
Brittany Renne
JSJanet R. Schoepflin
Janet R. Schoepflin
DDDiane Davis
Diane Davis
Purpose: The purpose of this study is to determine the accuracy of smartphone sound level meter applications (SLMAs) with calibration features across stimulus levels and for ambient room noise measures in the clinical setting. Method: The accuracy of 3 iOS-based smartphone SLMAs (SLMA1: Analyzer [Version 2.7.2, DSP Mobile], SLMA2: Sound Level Meter Pro [Version 2.2, Mint Muse LLC], and SLMA3: SPL Meter [Version 9.3, Andrew Smith, Studio Six Digital]), using a single smartphone device (iPhone 6S Model A1688, iOS 9.3.4, Apple), was evaluated with and without calibration using a 1000-Hz narrowband noise (NBN) and white noise (WN) stimuli over a range of sound levels (20–100 dB) and in ambient noise measures of 8 speech and hearing room environments. A simultaneous and corresponding SLMA and Type 1 sound level meter (SLM) measure per condition were documented with a photo image; each condition was replicated 5 times. Mean SLMA and SLM measures were compared. SLMA measures were considered accurate if within ± 2 dB of the SLM. Results: Measures of NBN and WN signals using these SLMAs were accurate at levels above 40–50 dB when calibrated. NBN and WN signals using some SLMAs were significantly ( p < .05) more accurate with calibration at levels > 40 to 50 dB. SLMA measures with or without calibration adjustment were inaccurate and overestimated room ambient noise levels < 50 dB. Conclusions: These findings suggest that some SLMAs are accurate for measuring NBN and WN stimuli within the range of 50–100 dB in sound-treated environments when calibrated. However, outcomes indicated that some SLMAs, even with calibration, overestimated low ambient noise levels and may not accurately verify quiet room environments < 50 dB for clinical services. These results should not be generalized for all smartphone types, and continued research on SLMAs using next-generation smartphone devices is warranted.

1 March 2015 in Contemporary Issues in Communication Science and Disorders
Verified
Journal Article
Closed access
ADAmanda M. DelGiacco
Amanda M. DelGiacco
YSYula Serpanos
Yula Serpanos
EGEmily Gunderson
Emily Gunderson

3 March 2022 in American Journal of Audiology
Verified
Journal Article
Open access
YSYula Serpanos
Yula Serpanos
MHMelissa Hobbs
Melissa Hobbs
KNKarina Nunez
Karina Nunez
LGLucia Gambino
Lucia Gambino
JBJasmin Butler
Jasmin Butler
Purpose: This investigation aims to provide outcomes from a clinical perspective on the validity and efficacy of a wireless automated audiometer system that could be used in multiple settings when a sound booth is not accessible. Testing was conducted in a clinical setting under modified protocols meeting safety precautions during the COVID-19 pandemic. Method: Four doctoral students in audiology served as examiners. Participants were 69 adults between the ages of 20 and 69 years, with normal hearing (≤ 25 dB HL; n = 110 ears) or hearing loss (> 25 dB HL; n = 25 ears). Two versions of a pure-tone air-conduction threshold test following a modified Hughson-Westlake approach were performed and compared at 500, 1000, 2000, 3000, 4000, 6000, and 8000 Hz (a) in a sound-treated test booth using standard manual audiometry and (b) in a quiet, nonsound-treated clinical room (sound booth free) using automated KUDUwave audiometry. Participants were asked to complete a five-item feedback questionnaire, and examiners were interviewed to report on their experience. Results: Clinical validity to within ±10 dB of standard audiometry was demonstrated for 94.5% of the total thresholds ( n = 937) measured with the sound booth–free approach. Less accuracy (73.3%) was observed using a ±5 dB comparison. When comparing the mean thresholds, there were significant differences ( p < .01) between the mean thresholds at most frequencies, with mean sound booth thresholds being higher than the sound booth–free mean thresholds. A strong threshold correlation (.91–.98) was found between the methods across frequencies. Participant and examiner feedback supported the efficacy of the sound booth–free technology. Conclusions: Findings support sound booth–free, automated software-controlled audiometry with active noise monitoring as a valid and efficient procedure for pure-tone hearing threshold assessment. This method offers an effective alternative when circumstances require more transportable hearing assessment technology or do not allow for standard manual audiometry in a sound booth.

1 July 2004 in Journal of the American Academy of Audiology
Verified
Journal Article
Closed access
PDF file
YSYula Serpanos
Yula Serpanos
JGJudith S. Gravel
Judith S. Gravel
The test efficiency and reliability of loudness assessment using a computer-controlled method of cross-modality matching (CMM) between line length and loudness was investigated in children 4 to 12 years with normal hearing or mild to severe degrees of sensorineural hearing loss. Adult listeners with normal hearing served as a comparison group. Computer-generated visual and acoustic stimuli were used to derive individual loudness data.Children and adults with normal hearing presented with similar loudness functions, while children with sensorineural hearing loss had steeper functions than their normal-hearing counterparts. Retest data supported reliability of the CMM method with children within the current study and between previous studies performed with a similar, but manual, method. The computer CMM approach proved more time efficient than the manual one, halving the test time. The CMM loudness task in a computerized version may have potential in a research or clinical setting, in particular for individualizing hearing aid fittings with children. Se investigó la eficiencia y la confiabilidad de una prueba de evaluación de la intensidad subjetiva utilizando un método controlado por computadora de ordenamiento por modalidad cruzada (cross-modality matching: CMM) entre la longitud de la línea y la sonoridad, en niños de 4 a 12 años con audición normal o con hipoacusias sensorineurales de grado leve a severo. El grupo de comparación fue constituido por sujetos adultos con audición normal. Se utilizaron estímulos acústicos y visuales generados por computadora para establecer los datos individuales de intensidad subjetiva.Los niños y adultos con audición normal mostraron funciones de intensidad subjetiva similares, mientras que los niños con alteraciones auditivas sensorineurales obtuvieron funciones con pendiente más pronunciada que sus contrapartes normo-oyentes. Los datos de re-evaluación apoyaron la confiabilidad del método de CMM en niños, con relación al estudio actual y a estudios previos, realizados con un método similar, aunque manual. El enfoque computarizado CMM demostró ser más tiempo-eficiente que el manual, reduciendo a la mitad el tiempo de examen. La tarea de reconocimiento de la intensidad subjetiva por CMM, en una versión computarizada, puede tener potencial en un contexto clínico o de investigación, en particular, para individualizar la adaptación de auxiliares auditivos en niños.