Diana Cantor

Mrs. Diana Cantor

Universidad Nacional de Colombia, Medellín, Antioquia, Colombia
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 July 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
DCDiana Cantor
Diana Cantor
AOAndrés Ochoa
Andrés Ochoa
OMOscar Mesa
Oscar Mesa
The growing share of intermittent renewable energy sources raised complementarity to a central concept in the electricity supply industry. The straightforward case of two sources suggests that to guarantee supply, the time series of both sources should be negatively correlated. Extrapolation made Pearson’s correlation coefficient (ρ) the most widely used metric to quantify complementarity. This article shows several theoretical and practical drawbacks of correlation coefficients to measure complementarity. Consequently, it proposes three new alternative metrics robust to those drawbacks based on the natural interpretation of the concept: the Total Variation Complementarity Index (ϕ), the Variance Complementarity Index (ϕ′), and the Standard Deviation Complementarity Index (ϕs). We illustrate the use of the three indices by presenting one theoretical and three real case studies: (a) two first-order autoregressive processes, (b) one wind and one hydropower energy time series in Colombia at the daily time resolution, (c) monthly water inflows to two hydropower reservoirs of Colombia with different hydrologic regimes, and (d) monthly water inflows of the 15 largest hydropower reservoirs in Colombia. The conclusion is that ϕ outperforms the use of ρ to quantify complementarity because (i) ϕ takes into account scale, whereas ρ is insensitive to scale; (ii) ρ does not work for more than two sources; (iii) ρ overestimates complementarity; and (iv) ϕ takes into account other characteristics of the series. ϕ′ corrects the scale insensitivity of ρ. Moreover, it works with more than two sources. However, it corrects neither the overestimation nor the importance of other characteristics. ϕs improves ϕ′ concerning the overestimation, but it lets out other series characteristics. Therefore, we recommend total variation complementarity as an integral way of quantifying complementarity.

14 September 2025 in International Journal of Energy and Water Resources
Verified
Journal Article
Open access
PDF file
AOAndrés Ochoa
Andrés Ochoa
JRJ. J. Rivera
J. J. Rivera
DCDiana Cantor
Diana Cantor
This study examines the influence of the El Niño–Southern Oscillation on the statistical distribution of daily inflows to the 15 most important hydropower reservoirs across Colombia over the period 2000–2024. Twenty-five years of daily streamflow data were analyzed to determine whether El Niño–Southern Oscillation phases (La Niña, Normal, El Niño) produce statistically distinct hydrological signatures. Using the Oceanic Niño Index to classify each month into one of the three El Niño–Southern Oscillation phases, daily inflow records were grouped accordingly and applied the Anderson–Darling test to evaluate statistical differences among distributions. The analysis was performed independently for each river and calendar month, resulting in 540 pairwise comparisons. Six of eight possible outcome patterns were observed, with the most frequent pattern–rejection of the null hypothesis in all three comparisons–occurring in nearly 70% of the 180 river-month cases, indicating strong phase-dependent hydrological differentiation. The results exhibit clear spatial and temporal variability in El Niño–Southern Oscillation influence, with strongest signals during December–March and considerable complementarity among major reservoirs. By comparing monthly and daily streamflow statistics, the analysis demonstrates that daily resolution provides richer and more operationally relevant information, especially for reservoir management. These findings highlight the value of incorporating El Niño–Southern Oscillation-phase-resolved diagnostics into water resources planning and energy system operations in tropical regions influenced by climate variability.

29 June 2021 in TechRxiv
Verified
Preprint
Open access
PDF file
DCDiana Cantor
Diana Cantor
AOAndrés Ochoa
Andrés Ochoa
OMOscar Mesa
Oscar Mesa
Complementarity has become an essential concept in energy supply systems. Although there are some other metrics, most studies use correlation coefficients to quantify complementarity. The standard interpretation is that a high negative correlation indicates a high degree of complementarity. However, we show that the correlation is not an entirely satisfactory measure of complementarity. As an alternative, we propose a new index based on the mathematical concept of the total variation. For two time series, the new index φ is one minus the ratio of the total variation of the sum to the sum of the two series’ total variation. We apply the index first to an auto-regressive (AR) process and then to various Colombian electric system series. The AR case clearly illustrates the limitations of the correlation coefficient as a measure of complementarity. We then evaluate complementarity across various space-time scales in the Colombian power sectors, considering hydro and wind projects. The complementarity assessment on a broad temporal and geographical scale helps analyze large power systems with different energy sources. The case study of the Colombian hydropower systems suggests that φ is better than ρ because (i) it considers scale, whereas ρ, being non-dimensional, is insensitive to the scale and even to the physical dimensions of the variables; (ii) one can apply φ to more than two resources; and (iii) ρ tends to overestimate complementarity.