In this paper, Ti:Sa amplifiers with crystals of the different geometries are discussed. Benefits of using this active medium for a thin disk (TD) and slab amplifiers are evaluated numerically and tested experimentally. Thermal management for amplifiers with multi-kW average power and multi-J pulse energy has been demonstrated. The presented numerical simulations revealed the existing limitations for heat extraction in TD geometry in the sub-joule energy regime for higher repetition rate operation. Geometry conversion from TD to thin-slab (TS) and cross-thin-slab (XTS) configurations significantly increases the cooling efficiency with an acceptable crystal temperature for pump average power values up to few kW with room temperature cooling, and up to tens of kW with cryogenic cooling. The abilities to attain 0.3 J output energy and a greater than 50% extraction efficiency were demonstrated with a repetition rate exceeding 10 kHz with room temperature cooling and one order more of a repetition rate with cryogenic conditions with pulsed pumping. Direct diode pumping simulated for CW regimes demonstrated 1.4 kW output power with 34% extraction efficiency using room temperature cooling and more than 10 kW and ~40% efficiency with cryogenic cooling.
We demonstrate a room-temperature Ti:Sapphire (Ti:Sa) amplifier that uses a cross pump-seed geometry (cross-thin-slab) to generate 30-mJ output pulses at 0.5-kHz repetition rate, and 25 mJ at 1 kHz when pumped by 100-mJ, 515-nm pulses from a diode-pumped Yb:YAG laser. The geometry allows to maintain a crystal temperature of ∼30°C using cooling water at 10°C. The amplifier is an attractive solution for use in the first stages of amplification in high peak and high average power chirped pulse amplification laser systems.
In this paper, the different Ti:Sapphire crystal configurations of the final amplifiers, depending on the Chirped Pulse Amplification laser system parameters, such as the repetition rates and pulse energy, are discussed. Restrictions placed on the final Ti:Sa amplifiers with a high repetition rate are discussed. The repetition rate of these systems is limited due to the crystal overheating, which leads to stress fracturing or significant beam distortion. The heating density threshold leading to stress fracturing was calculated and taken as the limit of the upper level of the possible pump average power. On the basis of these calculations, the highest repetition rates and corresponding thermolens focal distances were estimated for conventional crystal geometry of the most suitable thicknesses. It was demonstrated that conventional crystal shapes, such as a thin disc, can be used for systems with repetition rates below a few hundred Hz if several Joules of the output pulse energy are required. The rectangular thin crystal plate geometry was more suitable for Ti:Sa amplifiers with repetition rates above 1 kHz. Finally, the parameters of rectangular thin crystal plate Ti:Sa laser amplifier with an output energy above 3 J per pulse for a laser system with more than 100 TW pulse power and 1 kHz repetition rates are presented.
Post-compression of high energy laser pulses by folded free propagation MPC in atmospheric air is presented. Proof-of-principle experiments demonstrate the ability of this scheme to compress the 0.1J-level energy pulses up to 10 times scalable.
A proof-of-principle experiment demonstrates post-compression by a factor of ~six of 0.1 J-level Yb:YAG picosecond laser pulses spectrally broadened by free beam propagation in atmospheric air folded by flat mirrors.