Nisha Hollingsworth

Ms. Nisha Hollingsworth

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Fuel Processing Technology
Verified
Journal Article
Closed access
SWSabina I. Wilkanowicz
Sabina I. Wilkanowicz
NHNisha Hollingsworth
Nisha Hollingsworth
KSKeara Saud
Keara Saud
UKUsha Kadiyala
Usha Kadiyala
Ronald LarsonRonald Larson
Ronald Larson

12 July 2017 in Biomedical Materials
Verified
Journal Article
Closed access
PDF file
TGTinotenda Gwisai
Tinotenda Gwisai
NHNisha Hollingsworth
Nisha Hollingsworth
SCSarah Cowles
Sarah Cowles
NTNagendran Tharmalingam
Nagendran Tharmalingam
EMEleftherios Mylonakis
Eleftherios Mylonakis
ASAnita Shukla
Anita Shukla
Device-associated and hospital-acquired infections remain amongst the greatest challenges in regenerative medicine. Furthermore, the rapid emergence of antibiotic resistance and lack of new classes of antibiotics has made the treatment of these bacterial infections increasingly difficult. The repurposing of Food and Drug Administration approved drugs for antimicrobial therapies is a powerful means of reducing the time and cost associated with drug discovery and development. In this work, niclosamide, a commercially available anthelmintic drug with recently identified antimicrobial properties, was found to prevent the formation of, and combat existing biofilms of, several relevant Gram-positive bacteria, namely strains of Staphylococcus aureus , including methicillin resistant S. aureus (MRSA), and Staphylococcus epidermidis , all common causes of hospital-acquired and device-associated infections. This anti-biofilm activity was demonstrated at niclosamide concentrations as low as 0.01 μ g ml −1 . We then assessed niclosamide activity as an antibacterial coating, which could potentially be applied to medical device surfaces. We developed solvent cast niclosamide coatings on a variety of surfaces common amongst medical devices including glass, titanium, stainless steel, and aluminum. Niclosamide-coated surfaces exhibited potent in vitro activity against S. aureus , MRSA, and S. epidermidis . At niclosamide surface concentrations as low as 1.6 × 10 −2 μ g mm −2 , the coatings prevented attachment of these bacteria. The coatings also cleared bacteria inoculated suspensions at niclosamide surface concentrations of 3.1 × 10 −2 μ g mm −2 . Hemolysis was not observed at any of the antimicrobial coating concentrations tested. We report a facile, effective means of coating devices with niclosamide to both clear and prevent biofilm formation of common bacteria encountered in hospital-acquired and device-associated infections.

12 September 2019 in Soft Matter
Verified
Journal Article
Closed access
PDF file
NHNisha Hollingsworth
Nisha Hollingsworth
SWSabina I. Wilkanowicz
Sabina I. Wilkanowicz
Ronald LarsonRonald Larson
Ronald Larson
We infer the swelling/de-swelling behavior of weakly ionizable poly(acrylic acid) (PAA) brushes of 2–39 kDa molar mass in the presence of KCl concentrations from 0.1–1000 mM, pH = 3, 7, and 9, and grafting densities σ = 0.12–2.15 chains per nm2 using a Quartz Crystal Microbalance with Dissipation (QCM-D), confirming and extending the work of Wu et al. to multiple chain lengths. At pH 7 and 9 (above the pKa ∼ 5), the brush initially swells at low KCl ionic strength (<10 mM) in the “osmotic brush” regime, and de-swells at higher salt concentrations, in the “salted brush” regime, and is relatively unaffected at pH 3, below the pKa, as expected. At pH 7, at low and moderate grafting densities, our results in the high-salt “salted brush” regime (Cs > 10 mM salt) agree with the predicted scaling H ∼ Nσ+1/3Cs −1/3 of brush height H, while in the low-salt “osmotic brush” regime (Cs < 10 mM salt), we find H ∼ Nσ+1/3Cs +0.28–0.38, whose dependence on Cs agrees with scaling theory for this regime, but the dependence on σ strongly disagrees with it. The predicted linearity in the degree of polymerization N is confirmed. The new results partially confirm scaling theory and clarify where improved theories and additional data are needed.

6 March 2021 in Polymers
Verified
Journal Article
Open access
PDF file
NHNisha Hollingsworth
Nisha Hollingsworth
Ronald LarsonRonald Larson
Ronald Larson
We use a quartz crystal microbalance with dissipation (QCM-D) to investigate the swelling/de-swelling and hysteresis in brushes of weakly ionizable polyanion poly(acrylic acid) (PAA) brushes and bilayers containing a PAA brush and a poly(ethylene imine) (PEI) overlayer