Understanding the irradiated area and dose correctly is important for the reirradiation of organs that deform after irradiation, such as the liver. We investigated the spatial registration error using the deformable image registration (DIR) software products MIM Maestro (MIM) and Velocity AI (Velocity). Image registration of pretreatment computed tomography (CT) and posttreatment CT was performed in 24 patients with liver tumors. All the patients received proton beam therapy, and the follow-up period was 4–14 (median: 10) months. We performed DIR of the pretreatment CT and compared it with that of the posttreatment CT by calculating the dislocation of metallic markers (implanted close to the tumors). The fiducial registration error was comparable in both products: 0.4–32.9 (9.3 ± 9.9) mm for MIM and 0.5–38.6 (11.0 ± 10.0) mm for Velocity, and correlated with the tumor diameter for MIM (r = 0.69, P = 0.002) and for Velocity (r = 0.68, P = 0.0003). Regarding the enhancement effect, the fiducial registration error was 1.0–24.9 (7.4 ± 7.7) mm for MIM and 0.3–29.6 (8.9 ± 7.2) mm for Velocity, which is shorter than that of plain CT (P = 0.04, for both). The DIR performance of both MIM and Velocity is comparable with regard to the liver. The fiducial registration error of DIR depends on the tumor diameter. Furthermore, contrast-enhanced CT improves the accuracy of both MIM and Velocity. H28-102; July 14, 2016 approved.
1 July 2020 in Journal of Oral and Maxillofacial Surgery
Lymphocytes play an important role in the cancer immune system. In the present study, we aimed to evaluate the associations of lymphopenia during proton beam therapy (PBT) and concurrent chemotherapy with clinical outcomes and to determine whether lung or bone is more influential on lymphopenia during PBT. Data from 41 patients with stage III non-small cell lung cancer (NSCLC) who received PBT of 74 GyE with concurrent chemotherapy between 2007 and 2017 were reviewed retrospectively. The correlation between dosimetry parameters obtained from dose–volume histograms of the bone and lung and lymphopenia during PBT were analyzed. Minimum absolute lymphocyte count (ALCmin) and maximum neutrophil/lymphocyte ratio (NLRmax) were used as indicators of lymphopenia. Bone V5–20 and lung V5–50 were significantly correlated with the ALCmin and NLRmax during PBT. Multivariable analysis showed that the NLRmax, but not the ALCmin, was associated with overall survival (OS), progression-free survival (PFS) and distant metastasis-free survival (DMFS). The 3-year rates of OS, PFS and DMFS of patients with a low (≤ 6.3) versus high (> 6.3) NLRmax were 73.9% vs 44.4% (P = 0.042), 26.1% vs 5.6% (P = 0.022) and 39.1% vs 5.6% (P < 0.001), respectively. Lung V20 was significantly associated with DMFS on multivariable analyses (hazard ratio: 1.094, P = 0.008), whereas bone V5 had no impact on survival outcomes. We concluded that the NLRmax was a better prognostic indicator than the ALCmin, and the lung dose had more influence than the bone dose on the main survival outcomes in stage III NSCLC patients treated with PBT combined with concurrent chemotherapy.
The purpose of this study was to evaluate the reproducibility of visual feedback-guided breath-hold using a machine vision system with a charge-coupled device camera and a monocular head-mounted display. Sixteen patients with lung tumors who were treated with stereotactic radiotherapy were enrolled. A machine vision system with a charge-coupled device camera was used for monitoring respiration. A monocular head-mounted display was used to provide the patient with visual feedback about the breathing trace. The patients could control their breathing so that the breathing waveform would fall between the upper and lower threshold lines. Planning and treatment were performed under visual feedback-guided expiratory breath-hold. Electronic portal images were obtained during treatment. The range of cranial-caudal motion of the tumor location during each single breath-hold was calculated as the intra-breath-hold (intra-BH) variability. The maximum displacement between the two to five averaged tumor locations of each single breath-hold was calculated as the inter-breath-hold (inter-BH) variability. All 16 patients tolerated the visual feedback-guided breath-hold maneuvers well. The intra- and inter-BH variability of all patients was 1.5 +/- 0.6 mm and 1.2 +/- 0.5 mm, respectively. A visual feedback-guided breath-hold technique using the machine vision system is feasible with good breath-hold reproducibility.
Background/Aim: To evaluate the outcomes of proton beam therapy (PBT) for early-stage non-small cell lung cancer (NSCLC) in patients with interstitial lung disease (ILD). Patients and Methods: Between 2002 and 2017, 110 patients receiving hypofractionated PBT for cT1-2N0M0 NSCLC were reviewed. Results: Of the 110 patients, 17 were diagnosed with ILD. The median follow-up period was 37.8 months. No significant difference in the 1-year cumulative rate of grade ≥2 pneumonitis was observed between patients with and those without ILD (17.6% vs. 14.1%, p=0.708). The lung doses were significantly lower in patients with than in those without ILD among patients without grade ≥2 pneumonitis. There were no significant differences in overall survival or local recurrence-free rates according to the presence of ILD. Conclusion: PBT appears to be a feasible and effective treatment for cT1-2N0M0 NSCLC in patients with ILD, but the lung dose should be strictly reduced.