Javier Montero

Dr. Javier Montero

University of Salamanca (Salamanca, SPAIN)
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2013 in Journal of Dentistry
Verified
Journal Article
Closed access
AGAna Luísa Gomes
Ana Luísa Gomes
RCRaquel Castillo-Oyagüe
Raquel Castillo-Oyagüe
CLChristopher D. Lynch
Christopher D. Lynch
Javier MonteroJavier Montero
Javier Montero
AAAlberto Albaladejo
Alberto Albaladejo

1 January 2009
Verified
Journal Article
Closed access
Javier MonteroJavier Montero
Javier Montero
MBManuel Bravo
Manuel Bravo
AAAlberto Albaladejo-Martínez
Alberto Albaladejo-Martínez
LHLuis Antonio Hernández-Martín
Luis Antonio Hernández-Martín
EREva María Rosel-Gallardo
Eva María Rosel-Gallardo

1 April 2016 in Implant Dentistry
Verified
Journal Article
Closed access
GMGuillermo Manzano
Guillermo Manzano
Javier MonteroJavier Montero
Javier Montero
FMFrancisco Javier Martin-Vallejo
Francisco Javier Martin-Vallejo
MFMassimo Del Fabbro
Massimo Del Fabbro
MBManuel Bravo
Manuel Bravo
TTTiziano Testori
Tiziano Testori
Clinicians should be able to weigh the role of the main risk factors associated with early implant failure. The aim of this meta-analysis was to assess the influence of different patient-related and implant-related risk factors on the occurrence of early implant failure. In July, 2014 the main electronic databases were searched for studies reporting on early failures. Relevant papers were selected by 2 independent authors using predefined selection criteria. Three authors independently scored the included studies for quality assessment. The estimated odds ratios of the main risk factors from the selected papers were subjected to meta-analysis. Nine studies were included. A total of 18,171 implants were meta-analyzed, of which 10,921 were analyzed for smoking, 15,260 for implant diameter, 16,075 for implant length, and 16,711 for implant location (maxilla vs mandible). The main significant risk factors for early implant failures were the smoking habit (odds ratio [OR], 1.7; 95% confidence interval [CI], 1.3, 2.3), implants shorter than 10 mm (OR, 1.6; 95% CI, 1.2, 2.2) and implants placed in the maxilla (OR, 1.3; 95% CI, 1.0, 1.6). Clinicians should be aware of the increased risk of early failure in the presence of smokers, implants with reduced length, and implant-supported maxillary rehabilitation.

1 January 2014 in The International Journal of Oral and Maxillofacial Implants
Verified
Journal Article
Closed access
GMGuillermo Manzano
Guillermo Manzano
LHL. Rubén Herrero
L. Rubén Herrero
Javier MonteroJavier Montero
Javier Montero
Guillermo Manzano, DDS/L. Rub?n Herrero, DDS/Javier Montero, DDS, PhD: Purpose: This study aimed to compare the values of removal torque (RT) and bone-implant contact (BIC) reported in different animal studies for zirconia and titanium implants. Materials and Methods: A systematic review of the literature was performed to analyze BIC and RT of animal studies in which both zirconia and titanium dental implants were used. To identify the studies to include in this systematic review, an exhaustive search of PubMed was performed of animal studies published in English with reports on the quantification of the osseointegration of both titanium and zirconia implants by means of BIC and/or RT. The results were aggregated and analyzed within each of the animal models (pig, rabbit, rat, monkey, dog, and sheep). Results: The selection process resulted in a final sample of 16 studies. In general, no significant differences were found between titanium and zirconia. The significant differences in terms of BIC and RT reported by the authors were attributable to the different surface treatments and microporosities of the implant surfaces studied, not to the materials themselves. Only two articles reported significantly lower BIC for modified zirconia implants as compared to modified titanium implants. Four authors described statistically significant differences in terms of RT between zirconia and titanium implants in the different animal models, regardless of the surface treatment received by the implants. Conclusions: Within the limitations of this study, the values for the BIC and RT of zirconia implants in most of the studies analyzed did not show statistical differences compared with titanium implants. Modified-surface zirconia may have potential as a candidate for a successful implant material, although further clinical studies are necessary.

23 February 2018 in Clinical Oral Investigations
Verified
Journal Article
Closed access
PDF file
FAF. Aragón
F. Aragón
MZM. A. Zea-Sevilla
M. A. Zea-Sevilla
Javier MonteroJavier Montero
Javier Montero
PSP. Sancho
P. Sancho
RCR. Corral
R. Corral
AAA. Albaladejo
A. Albaladejo

1 June 2013 in Journal of Dentistry
Verified
Journal Article
Closed access
Javier MonteroJavier Montero
Javier Montero
RCRaquel Castillo-Oyagüe
Raquel Castillo-Oyagüe
CLChristopher D. Lynch
Christopher D. Lynch
AAAlberto Albaladejo
Alberto Albaladejo
ACAntonio Castaño
Antonio Castaño