The purpose of this pilot study was to investigate whether transcranial static magnetic field stimulation (tSMS), which can modulate cortical excitability, would influence inhibitory control function when applied over the dorsolateral prefrontal cortex (DLPFC). Young healthy adults (n = 8, mean age ± SD = 24.4 ± 4.1, six females) received the following stimulations for 30 min on different days: (1) tSMS over the left DLPFC, (2) tSMS over the right DLPFC, and (3) sham stimulation over either the left or right DLPFC. The participants performed a Go/NoGo task before, immediately after, and 10 min after the stimulation. They were instructed to extend the right wrist in response to target stimuli. We recorded the electromyogram from the right wrist extensor muscles and analyzed erroneous responses (false alarm and missed target detection) and reaction times. As a result, 50% of the participants made erroneous responses, and there were five erroneous responses in total (0.003%). A series of statistical analyses revealed that tSMS did not affect the reaction time. These preliminary findings suggest the possibility that tSMS over the DLPFC is incapable of modulating inhibitory control and/or that the cognitive load imposed in this study was insufficient to detect the effect.
BACKGROUND: Mirror illusion therapy (mirror therapy) is based on the experimental substrate of a visual illusion of active hand movement to excite ipsilateral primary motor cortex (iM1). PURPOSE: We tested whether iM1 excitability could be modulated
Transcranial static magnetic stimulation (tSMS) has been known to reduce human cortical excitability. Here, we investigated whether tSMS would modulate visuo-spatial cognition in healthy humans. Subjects performed a visuo-spatial task requiring judgements about the symmetry of pre-bisected lines. Visual stimuli consisted of symmetrically or asymmetrically transected lines, tachystoscopically presented for 150 ms on a computer monitor. Task performance was examined before, immediately after, and 10 min after tSMS/sham stimulation of 20 min over the posterior parietal cortex (PPC: P4 from the international 10–20 system) or superior temporal gyrus (STG: C6). Nine out of 16 subjects misjudged pre-bisected lines by consistently underestimating the length of the right-side segment (judging lines to be exactly pre-bisected when the transector was located to the left of the midpoint, or judging the left-side segment to be longer when the transector was located at the midpoint). In these subjects showing a leftward bias, tSMS over the right STG reduced the magnitude of the leftward bias. This did not occur with tSMS over the right PPC or sham stimulation. In the remaining right-biased subjects, no intervention effect was observed with any stimulation. Our findings indicate that application of tSMS over the right STG modulates visuo-spatial cognition in healthy adults.
Venous thrombosis has been shown to be the most frequent cause of free flap failure in traumatic lower extremity injuries. However, the roles of various anastomotic venous factors, including venous anastomosis (end-to-end (ETE) or end-to-side (ETS)), venous outflow (one vein or two veins), and recipient venous selection (deep or superficial vein), remain unclear. This retrospective study aims to investigate factors contributing to microvascular complications in patients with lower extremity Gustilo type IIIB/IIIC injuries reconstructed by free flap with a focus on the three abovementioned venous factors. A total of 44 flap treatment outcomes of 41 patients with these injuries from 2015 to 2020 were assessed according to the three venous factors (type of anastomosis, venous outflow, and vein selection). The average patient age was 52 years, with the majority (75.6%) being male. Eight patients (18.2%) returned to the operating room due to venous thrombosis, and five patients (11.4%) experienced total flap failure. The following factors were suspected to have contributed to venous thrombosis: vein size mismatch (n = 2) and recipient vein insufficiency possibly due to post-traumatic vessel disease (PTVD) (n = 6). End-to-side (ETS) anastomoses showed lower venous thrombosis rates than end-to-end (ETE) anastomoses (6.3% versus 25%, p = 0.22), two-vein outflows had lower rates than one (8.3% versus 30%, p = 0.07), and deep veins had the lowest thrombosis rates (7.7%), whereas superficial veins had the highest (38.5%). The key venous factors in preventing venous thrombosis include using as many two-vein ETS anastomoses as possible to deep recipient veins.