Nasim Shahidi Hamedani

Dr. Nasim Shahidi Hamedani

Institute of Experimental Haematology and Transfusion Medicine, University of Bonn, Bonn, Germany
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 February 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Nasim Shahidi HamedaniNasim Shahidi Hamedani
Nasim Shahidi Hamedani
Arijit BiswasArijit Biswas
Arijit Biswas
OROliver Rudan
Oliver Rudan
RTRosa Toenges
Rosa Toenges
CMCarlotta Meyring
Carlotta Meyring
BPBernd Pötzsch
Bernd Pötzsch
Coagulation factor XIII (FXIII) is a protransglutaminase which plays an important role in clot stabilization and composition by cross-linking the α- and γ-chains of fibrin and increasing the resistance of the clot to mechanical and proteolytic challenges. In this study, we selected six DNA aptamers specific for activated FXIII (FXIIIa) and investigated the functional characterization of FXIIIa after aptamer binding. One of these aptamers, named FA12, efficiently captures FXIIIa even in the presence of zymogenic FXIII subunits. Furthermore, this aptamer inhibits the incorporation of FXIII and α2-antiplasmin (α2AP) into fibrin(ogen) with IC50-values of 38 nM and 17 nM, respectively. In addition to FA12, also another aptamer, FA2, demonstrated significant effects in plasma-based thromboelastometry (rotational thromboelastometry analysis, ROTEM)-analysis where spiking of the aptamers into plasma decreased clot stiffness and elasticity (p < 0.0001). The structure–function correlations determined by combining modeling/docking strategies with quantitative in vitro assays revealed spatial overlap of the FA12 binding site with the binding sites of two FXIII substrates, fibrinogen and α2AP, while FA2 binding sites only overlap those of fibrinogen. Taken together, these features especially render the aptamer FA12 as an interesting candidate molecule for the development of FXIIIa-targeting therapeutic strategies and diagnostic assays.

8 May 2022 in Life
Verified
Journal Article
Open access
PDF file
SRSara Reda
Sara Reda
EREva Rudde
Eva Rudde
JMJens Müller
Jens Müller
Nasim Shahidi HamedaniNasim Shahidi Hamedani
Nasim Shahidi Hamedani
JOJohannes Oldenburg
Johannes Oldenburg
Heiko RuehlHeiko Ruehl
Heiko Ruehl
Direct oral anticoagulants (DOACs) apixaban and rivaroxaban are broadly used in the management of venous thromboembolism (VTE). Although not routinely required, measurement of their plasma concentration is advised for an increasing number of indications. Due to the lack of therapeutic ranges, current guidelines recommend reporting DOAC plasma levels together with expected levels from previous pivotal studies. The aim of this study was to assess DOAC level variation in a large VTE patient population. Drug concentrations determined by measurement of the anti-Xa-activity using drug-specific calibrators in citrated plasma samples from patients on rivaroxaban (n = 1471) or apixaban (n = 725) were analyzed. Observed 5th–95th percentile ranges of apixaban peak/trough levels (63–299/13–114 ng/mL for 5 mg, 37–161/7–68 ng/mL for 2.5 mg twice daily) were similar to previously reported mass-spectrometry-based reference data, and 10th–90th percentile ranges of rivaroxaban peak/trough levels (98–367/8–55 ng/mL for 20 mg, 51–211/5–27 ng/mL for 10 mg once daily) were even narrower. Age and drug levels correlated weakly (r ≤ 0.330). Drug levels measured repeatedly in subgroups of patients showed a strong correlation (r ≥ 0.773). In conclusion, anti-Xa-activity-based measurement of apixaban and rivaroxaban yields reliable results. However, the paucity of levels off-range underlines the need for evidence-based thresholds to better assist clinical decision making.

30 April 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Nasim Shahidi HamedaniNasim Shahidi Hamedani
Nasim Shahidi Hamedani
FHFelix Lucian Happich
Felix Lucian Happich
EKEva-Maria Klein
Eva-Maria Klein
HRHeiko Rühl
Heiko Rühl
GMGünter Mayer
Günter Mayer
BPBernd Pötzsch
Bernd Pötzsch
Activated protein C (APC) is a serine protease with anticoagulant and cytoprotective activities which make it an attractive target for diagnostic and therapeutic applications. In this work, we present one-step activation of APC from a commercial source of protein C (PC, Ceprotin) followed by rapid and efficient purification using an APC-specific aptamer, HS02-52G, loaded on MyOne superparamagnetic beads. Due to the Ca2+-dependent binding of APC to HS02-52G, an efficient capturing of APC was applied in the presence of Ca2+ions, while a gentle release of captured APC was achieved in the elution buffer containing low EDTA concentration (5 mM). The captured and eluted APC showed more than 95% purity according to SDS-PAGE gel analysis and an enzyme-linked fluorescent assay (VIDAS Protein C). The purification yield of 45% was calculated when 4.2 µg APC was used, however this yield reduced to 21% if the starting amount of APC increased to 28.5 µg. Altogether, this method is recommended for rapid and efficient PC activation and APC purification. The purified APC can be used directly for downstream processes where high concentration of pure and active APC is needed.

14 July 2022 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Nasim Shahidi HamedaniNasim Shahidi Hamedani
Nasim Shahidi Hamedani
JOJohannes Oldenburg
Johannes Oldenburg
BPBernd Pötzsch
Bernd Pötzsch
JMJens Müller
Jens Müller
Emicizumab mimics the hemostatic activity of activated factor VIII (FVIIIa) within the tenase complex. Despite functional similarities between FVIIIa and emicizumab, conventional laboratory methods designed for monitoring of FVIII activity are inappropriate for the measurement of emicizumab. At present, a modified one stage (FVIII) assay (mOSA) is mainly used for emicizumab monitoring. Two-stage chromogenic FVIII assays based on human factors can be used, although limited performance due to lack of corresponding optimization might be observed. Furthermore, the presence of FVIII or anticoagulants in the patient sample may falsify assay results. To address these issues, we optimized and evaluated a two-stage chromogenic assay (emi-tenase) for measurement of emicizumab in plasma samples. Heat inactivation of samples was established to abolish the influence of endogenous or substituted FVIII. The lower limit of quantification (LLoQ) was found to be 2 μg/ml in a manual assay format and 9.5 μg/ml on an automated coagulation analyzer. Intra- and inter-assay coefficients of variation (CV) did not exceed 20%. Analysis of 17 patient plasma samples with severe haemophilia A under emicizumab treatment showed good correlation of results between the emi-tenase assay and the mOSA (Cohens Kappa coefficient = 0.9). Taken together, the emi-tenase assay allows specific measurement of emicizumab plasma levels over a broad concentration range (10 μg/ml to 100 μg/ml). The assay can be applied on an automated coagulation analyzer, demonstrating its applicability within a routine laboratory setting.

7 February 2022 in Research Square
Verified
Preprint
Open access
PDF file
Nasim Shahidi HamedaniNasim Shahidi Hamedani
Nasim Shahidi Hamedani
FHFelix Lucian Happich
Felix Lucian Happich
EKEva-Maria Klein
Eva-Maria Klein
HRHeiko Rühl
Heiko Rühl
GMGünter Mayer
Günter Mayer
BPBernd Pötzsch
Bernd Pötzsch
Activated protein C (APC) is a serine protease with anticoagulant and cytoprotective activities which make it an attractive target for diagnostic and therapeutic applications. In this work, we present one-step activation of APC from a commercial source of protein C (PC, Ceprotin®) followed by rapid and efficient purification using the APC-specific aptamer HS02-52G loaded on MyOne superparamagnetic beads. Due to the Ca2+-dependent binding of APC to HS02-52G, an efficient capturing of APC was applied in the presence of Ca2+ ions, while a gentle release of captured APC was achieved in the elution buffer containing low EDTA concentration (5 mM). The captured and eluted APC showed more than 95% purity according to an enzyme-linked fluorescent assay (VIDAS® Protein C). The purification yield of 45% was calculated when 4.2 µg APC was used, however this yield reduced to 21% if the starting amount of PC increased to 28.5 µg. Altogether, this method is recommended for rapid and efficient PC activation and APC purification. The purified APC can be used directly for downstream processes where high concentration of pure and active APC is needed.