Ludovic Bellon

Dr. Ludovic Bellon


Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 October 1997 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
AGA. Garcimartín
A. Garcimartín
AGA. Guarino
A. Guarino
LBLudovic Bellon
Ludovic Bellon
SCS. Ciliberto
S. Ciliberto
We present the data of a mode-I fracture experiment. The samples are broken under imposed pressure. The acoustic emission of microfractures before the breakup of the sample is registered. From the acoustic signals, the position of microfractures and the energy released are calculated. A measure of the clustering of microfractures yields information about the critical load. The statistics from energy measurements strongly suggest that the fracture can be viewed as a critical phenomenon; energy events are distributed in magnitude as a power law, and a critical exponent is found for the energy near fracture.

27 April 2021 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
SDSalambô Dago
Salambô Dago
JPJorge Pereda
Jorge Pereda
NBNicolas Barros
Nicolas Barros
SCSergio Ciliberto
Sergio Ciliberto
LBLudovic Bellon
Ludovic Bellon
The Landauer principle states that at least kBTln2 of energy is required to erase a 1-bit memory, with kBT the thermal energy of the system. We study the effects of inertia on this bound using as one-bit memory an underdamped micromechanical oscillator confined in a double-well potential created by a feedback loop. The potential barrier is precisely tunable in the few kBT range. We measure, within the stochastic thermodynamic framework, the work and the heat of the erasure protocol. We demonstrate experimentally and theoretically that, in this underdamped system, the Landauer bound is reached with a 1% uncertainty, with protocols as short as 100 ms.

1 March 2010 in Europhysics Letters
Verified
Journal Article
Closed access
JGJ. R. Gomez-Solano
J. R. Gomez-Solano
LBLudovic Bellon
Ludovic Bellon
APA. Petrosyan
A. Petrosyan
SCS. Ciliberto
S. Ciliberto

1 February 2001 in Europhysics Letters
Verified
Journal Article
Closed access
LBLudovic Bellon
Ludovic Bellon
SCS Ciliberto
S Ciliberto
CLC Laroche
C Laroche

1 August 2002 in Physica D: Nonlinear Phenomena
Verified
Journal Article
Closed access
LBLudovic Bellon
Ludovic Bellon
SCS Ciliberto
S Ciliberto

1 September 2013 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PPPierdomenico Paolino
Pierdomenico Paolino
FAFelipe Aguilar
Felipe Aguilar
LBLudovic Bellon
Ludovic Bellon
In this article, we present a deflection measurement setup for Atomic Force Microscopy (AFM). It is based on a quadrature phase differential interferometer: we measure the optical path difference between a laser beam reflecting above the cantilever tip and a reference beam reflecting on the static base of the sensor. A design with very low environmental susceptibility and another allowing calibrated measurements on a wide spectral range are described. Both enable a very high resolution (down to \documentclass[12pt]{minimal}\begin{document}$2.5 \times 10^{-15}\,{\rm m}/\sqrt{\rm Hz}$\end{document}2.5×10−15m/ Hz ), illustrated by thermal noise measurements on AFM cantilevers. They present an excellent long-term stability and a constant sensitivity independent of the optical phase of the interferometer. A quick review shows that our precision is equaling or out-performing the best results reported in the literature, but for a much larger deflection range, up to a few μm.