Alicja Łukaszczyk

Dr. Alicja Łukaszczyk

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2021 in Materials
Verified
Journal Article
Open access
PDF file
FMFilip Maciąg
Filip Maciąg
TMTomasz Moskalewicz
Tomasz Moskalewicz
KKKazimierz Kowalski
Kazimierz Kowalski
AŁAlicja Łukaszczyk
Alicja Łukaszczyk
ZHZoya Hadzhieva
Zoya Hadzhieva
Aldo R. BoccacciniAldo R. Boccaccini
Aldo R. Boccaccini
Zein coatings were obtained by electrophoretic deposition (EPD) on commercially pure titanium substrates in an as-received state and after various chemical treatments. The properties of the zein solution, zeta potential and conductivity, at varying pH values were investigated. It was found that the zein content and the ratio of water to ethanol of the solution used for EPD, as well as the process voltage value and time, significantly influence the morphology of coatings. The deposits obtained from the solution containing 150 g/L and 200 g/L of zein and 10 vol % of water and 90 vol % of ethanol, about 4–5 μm thick, were dense and homogeneous. The effect of chemical treatment of the Ti substrate surface prior to EPD on coating adhesion to the substrate was determined. The coatings showed the highest adhesion to the as-received and anodized substrates due to the presence of a thick TiO2 layer on their surfaces and the presence of specific surface features. Coated titanium substrates showed slightly lower electrochemical corrosion resistance than the uncoated one in Ringer’s solution. The coatings showed a well-developed surface topography compared to the as-received substrate, and they demonstrated hydrophilic nature. The present results provide new insights for the further development of zein-based composite coatings for biomedical engineering applications.

22 July 2020 in Materials
Verified
Journal Article
Open access
PDF file
AFAleksandra Fiołek
Aleksandra Fiołek
SZSławomir Zimowski
Sławomir Zimowski
Kopia AgnieskaKopia Agnieska
Kopia Agnieska
AŁAlicja Łukaszczyk
Alicja Łukaszczyk
TMTomasz Moskalewicz
Tomasz Moskalewicz
The present study explores the possibilities of fabricating a graphite/polyetheretherketone (PEEK) composite coating on a Ti-6Al-4V titanium alloy through duplex treatment consisting of electrophoretic deposition (EPD) and heat treatment. It has been found that the electrophoretic co-deposition of graphite and PEEK microparticles can be performed from environmentally-friendly pure ethanolic suspensions. Zeta potential measurements and a study of the interaction between both particle types with the use of transmission electron microscopy allowed potential mechanisms of particle co-deposition to be indicated. Microstructure characterization was performed on macro-, micro- and nanoscale using visible light microscopy, X-ray diffractometry and electron microscopy. This allowed the coating homogeneity and distribution of graphite particles in the polymer matrix to be described. Graphite particles in the form of graphene nanosheet packages were relatively evenly distributed in the coating matrix and oriented parallel to the coating surface. The heat-treated coatings showed high scratch resistance and no adhesive type destruction was observed, but they were highly susceptible to deformation. The corrosion measurements were performed with use of electrochemical techniques like open circuit potential and linear sweep voltamperometry. The coated alloy indicated better electrochemical corrosion resistance compared with the uncoated alloy. This work showed the high versatility of the electrophoretic co-deposition of graphite and PEEK particles, which combined with post-EPD heat treatment allows composite coatings to be fabricated with controlled distribution of graphite particles.

18 October 2021 in Electrochem
Verified
Journal Article
Open access
PDF file
AŁAlicja Łukaszczyk
Alicja Łukaszczyk
JBJacek Banaś
Jacek Banaś
Marcin PisarekMarcin Pisarek
Marcin Pisarek
ASAntoine Seyeux
Antoine Seyeux
PMPhilippe Marcus
Philippe Marcus
Jolanta SwiatowskaJolanta Swiatowska
Jolanta Swiatowska
The electrochemical behavior of low alloyed Fe-Cr steels with 3 and 5% wt. of Cr in neutral Na2SO4 electrolyte combined with a detailed chemical and morphological characterization of these alloys performed by Auger electron spectroscopy, X-ray photoelectron spectroscopy, time-of-flight secondary ion mass spectrometry and scanning electron microscopy are presented here. The corrosion of low alloyed Fe-Cr steels proceeds in the prepassive range, with the formation of corrosion surface films having a duplex structure with outer iron oxide/hydroxide layer and inner Cr oxide-rich layer. The thickness, composition, and the morphology of the surface films vary as a function of chromium content in the alloy as well as conditions of electrochemical tests (temperature). Even a low chromium content shows a beneficial effect on the corrosion performances of the Fe-Cr steels. The chromium as a more active component than iron of ferrite increases the anodic activity of this phase, which results in a rapid saturation of the surface with the anodic reaction products forming a fine crystalline-like and compact layer of corrosion products. In this way, the chromium acts as a modifier of formation/crystallization of the iron-rich surface film (mainly magnetite) in the prepassive range.

Verified
Journal Article
Open access
PDF file
FKFilip Kuśmierczyk
Filip Kuśmierczyk
AFAleksandra Fiołek
Aleksandra Fiołek
AŁAlicja Łukaszczyk
Alicja Łukaszczyk
Kopia AgnieskaKopia Agnieska
Kopia Agnieska
Maciej SitarzMaciej Sitarz
Maciej Sitarz
TMTomasz Moskalewicz
Tomasz Moskalewicz
In this work, sulfonated polyetheretherketone (S-PEEK)-based coatings, nanocrystalline ZnS and hydroxyapatite (n-HA) particles were developed on Zr-2.5Nb zirconium alloy substrates by electrophoretic deposition (EPD) combined with subsequent heat treatment. The properties of suspensions and deposition kinetics were studied. Cationic chitosan polyelectrolyte ensured the stabilization of the suspension and allowed for the co-deposition of all coating components on the cathode. The heating of the coated samples at a temperature of 450 °C and slow cooling resulted in sulfonation of the PEEK and the formation of dense coatings. The coatings were characterized by high roughness, hardness, modulus of elasticity and adhesion strength. The coatings revealed mild hydrophilicity, improved the electrochemical corrosion resistance of the alloy and induced the formation of hydroxyapatite with a cauliflower-like morphology on its surface during the Kokubo test. This work explored the great development potential of advanced sulfonated PEEK-based coatings, incorporating antibacterial and bioactive components by EPD combined with heat treatment to stimulate the surface properties of zirconium alloy for prospective dental and orthopedic applications. The antibacterial and osteoconductive properties of the obtained coatings should be further investigated.

20 April 2021 in Materials
Verified
Journal Article
Open access
PDF file
AŁAlicja Łukaszczyk
Alicja Łukaszczyk
SZSławomir Zimowski
Sławomir Zimowski
WPWojciech Pawlak
Wojciech Pawlak
BDBeata Dubiel
Beata Dubiel
TMTomasz Moskalewicz
Tomasz Moskalewicz
In the present work, an oxygen hardening of near-β phase Ti–13Nb–13Zr alloy in plasma glow discharge at 700–1000 °C was studied. The influence of the surface treatment on the alloy microstructure, tribological and micromechanical properties, and corrosion resistance is presented. A strong influence of the treatment on the hardened zone thickness, refinement of the α’ laths and grain size of the bulk alloy were found. The outer hardened zone contained mainly an oxygen-rich Ti α’ (O) solid solution. The microhardness and elastic modulus of the hardened zone decreased with increasing hardening temperature. The hardened zone thickness, size of the α’ laths, and grain size of the bulk alloy increased with increasing treatment temperature. The wear resistance of the alloy oxygen-hardened at 1000 °C was about two hundred times, and at 700 °C, even five hundred times greater than that of the base alloy. Oxygen hardening also slightly improved the corrosion resistance. Tribocorrosion tests revealed that the alloy hardened at 700 °C was wear-resistant in a corrosive environment, and when the friction process was completed, the passive film was quickly restored. The results show that glow discharge plasma oxidation is a simple and effective method to enhance the micromechanical and tribological performance of the Ti–13Nb–13Zr alloy.

1 August 2023 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
FMFilip Maciąg
Filip Maciąg
TMTomasz Moskalewicz
Tomasz Moskalewicz
KKKatarzyna Cholewa - Kowalska
Katarzyna Cholewa - Kowalska
ZHZoya Hadzhieva
Zoya Hadzhieva
MDMichal Dziadek
Michal Dziadek
Aldo R. BoccacciniAldo R. Boccaccini
Aldo R. Boccaccini
Cu- and Mg-doped mesoporous sol-gel bioactive glasses (MSGG) were developed and their microstructure was investigated. Selected biological tests were also performed to assess their suitability for the functionalization of polymer zein coatings. The electrophoretic deposition (EPD) conditions to obtain composite coatings on Ti-13Nb-13Zr substrates were determined. The coatings with excellent adhesion to the substrates were macroscopically uniform, exhibiting open porosity and high roughness. The surfaces of the samples coated with MSGG/zein coatings became more hydrophilic than the titanium alloy substrates. However, with increase of the volume fraction of glass particles in the coatings, the contact angle increased. The coated alloy showed enhanced resistance to electrochemical corrosion in Ringer’s solution. The chemical composition of the glass used in the coating affected the parameters of wettability and resistance to electrochemical corrosion. Both coating types showed an increase in the antibacterial properties against Gram-negative (E. coli) and Gram-positive (S. aureus) bacteria compared to pure zein. However, no significant differences were observed after a 24 h-long test.