Damage is an inevitable occurrence in metallic structures and when unchecked could result in a catastrophic breakdown of structural assets. Non-destructive evaluation (NDE) is adopted in industries for assessment and health inspection of structural assets. Prominent among the NDE techniques is guided wave ultrasonic testing (GWUT). This method is cost-effective and possesses an enormous capability for long-range inspection of corroded structures, detection of sundries of crack and other metallic damage structures at low frequency and energy attenuation. However, the parametric features of the GWUT are affected by structural and environmental operating conditions and result in masking damage signal. Most studies focused on identifying individual damage under varying conditions while combined damage phenomena can coexist in structure and hasten its deterioration. Hence, it is an impending task to study the effect of combined damage on a structure under varying conditions and correlate it with GWUT parametric features. In this respect, this work reviewed the literature on UGWs, damage inspection, severity, temperature influence on the guided wave and parametric characteristics of the inspecting wave. The review is limited to the piezoelectric transduction unit. It was keenly observed that no significant work had been done to correlate the parametric feature of GWUT with combined damage effect under varying conditions. It is therefore proposed to investigate this impending task.
The two-tank water system is common practice for the storage and distribution of water in many homes. Water is transported via a pipeline network from the storage tank (lower tank) to the distribution tank (overhead tank) using an electric pumping machine. Due to limited control in the existing pumping system, water wastage becomes inevitable. Determining the quality of water in the overhead tank before supply in the home is still unaddressed. In this work, an integrated Android mobile App and a control system were developed to assess the water quality, perform level check in the overhead tank, and activate intelligent pumping control. An ultrasonic pulse-echo technique was used for water level checks, while the water turbidity and pH signals were used for water quality checks. Three-level control conditions (LC_1, LC_2, LC_3) and two water quality check conditions (QC_1 and QC_2) were devised and used in the intelligent control algorithm of the system. Control valve1 regulates the flushable poor water quality while valve2 regulates the house's supply of good water quality. The absolute relative error between the expected time and the system time of filling the tank level was observed to be less than 10% when the water volume is less than 81%. Hence, distortion in the sensory signals increases and worsen as the water level approaches the ultrasonic sensor position. The poor internet signal network was observed to affect the real-time monitoring and automation of the system control through delay in system responses to commands. However, the average recorded response time of the system is 3 s, and it could be less in the situation of good internet network services.
The positioning control of a dish antenna mounted on distributed mobile telemedicine nodes (DMTNs) within Nigeria communicating via NigComSat-1R has been presented. It was desired to improve the transient and steady performance of satellite dish antenna and reduce the effect of delay during satellite communication. In order to overcome this, the equations describing the dynamics of the antenna positioning system were obtained and transformed into state space variable equations. A full state feedback controller was developed with forward path gain and an observer. The proposed controller was introduced into the closed loop of the dish antenna positioning control system. The system was subjected to unit step forcing function in MATLAB/Simulink simulation environment considering three different cases so as to obtain time domain parameters that characterized the transient and steady state response performances. The simulation results obtained revealed that the introduction of the full state feedback controller provided improved position tracking to unit step input with a rise time of 0.42 s, settling time of 1.22 s and overshoot of 4.91%. With the addition of observer, the rise time achieved was 0.39 s, settling time of 1.31 s, and overshoot of 10.7%. The time domain performance comparison of the proposed system with existing systems revealed its superiority over them.
Despite the acclaimed long-term benefits of solar PV systems, most stand-alone solar projects in Nigeria seem to fail within a short duration. In this work, an analysis is carried out to examine the factors that lead to such poor performance of solar projects in Nigeria. A case study of standalone solar street lights (SASSL) in Nsukka geographical region in Nigeria was explored. The field work was carried out from Dec 2016 - January 2018. Data from field indicate that in most cases, premature battery failure due to undercharging was responsible for the collapse of these stand-alone solar systems. Given that the PV module is the sole charge generator in SASSL, the energy yield of the PV modules used in the SASSLs were further investigated. Controlled experiments were carried out to determine the impact of specific environmental and installations conditions on the yield of the PV modules. The results of the experiments led to the development of a model. The weather and installation specific data were then inserted into the model and were used to determine the likely reasons for the premature failure of SASSLs. The results indicated that the within the period under review, the PV modules were capable of providing adequate energy to the battery for only 25% of the time. For another 25% of the time the energy provided were marginal while for 50% of the time the energy provided were grossly inadequate. Keywords: Failure, Battery, Dust, Solar, mechanism, Street light, Irradiance, PV Module.
Human health monitoring (HHM) is essential for continued daily task execution, as is structural health monitoring (SHM) for structures to ensure the continual performance of their designed tasks with optimal efficiency. The existence of damage in a structure affects its optimal use through stiffness deterioration. Damage of different forms could occur in a structure but have the singular objective of material degradation, leading to its underuse for a task. Guided wave ultrasonics has shown strength in detecting sundry damage in structures, but most of the damage monitored and detected is unfilled with substances. However, some damage could trap and accumulate substances that could hasten material degradation through corrosion activities under favorable conditions, especially in the oil and gas industry. This study used the ultrasonic-guided waves’ pitch–catch inspection technique to identify damage filled with different materials. The assessment was based on the RMSD of the dominant Lamb wave mode’s average maximum amplitude and the response signals’ transmission coefficient (TC). A five-cycle tone burst of excitation signals of different frequencies was created to generate propagating Lamb waves in the structure. The fundamental antisymmetric mode was found to be more sensitive than the fundamental symmetric mode when detecting damage filled with various substances. At 80 kHz, the deviation of the current response signals from the baseline response signals due to different filled substances in the damage was distinct and decreased with increased fluid viscosity. Given that structures in the oil and gas sector are particularly susceptible to substance-induced damage, the outcomes of this study are paramount.