Nancy Karuri

Prof. Nancy Karuri


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 January 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
KKKawaljit Kaur
Kawaljit Kaur
WCWinny Chelangat
Winny Chelangat
SDSergey I. Druzhinin
Sergey I. Druzhinin
NKNancy Karuri
Nancy Karuri
MMMareike Müller
Mareike Müller
Holger SchönherrHolger Schönherr
Holger Schönherr
There is a growing demand for rapid and sensitive detection approaches for pathogenic bacteria that can be applied by non-specialists in non-laboratory field settings. Here, the detection of the typical E. coli enzyme β-glucuronidase using a chitosan-based sensing hydrogel-coated paper sensor and the detailed analysis of the reaction kinetics, as detected by a smartphone camera, is reported. The chromogenic reporter unit affords an intense blue color in a two-step reaction, which was analyzed using a modified Michaelis–Menten approach. This generalizable approach can be used to determine the limit of detection and comprises an invaluable tool to characterize the performance of lab-in-a-phone type approaches. For the particular system analyzed, the ratio of reaction rate and equilibrium constants of the enzyme–substrate complex are 0.3 and 0.9 pM−1h−1 for β-glucuronidase in phosphate buffered saline and lysogeny broth, respectively. The minimal degree of substrate conversion for detection of the indigo pigment formed during the reaction is 0.15, while the minimal time required for detection in this particular system is ~2 h at an enzyme concentration of 100 nM. Therefore, this approach is applicable for quantitative lab-in-a-phone based point of care detection systems that are based on enzymatic substrate conversion via bacterial enzymes.

30 July 2022 in Chemosensors
Verified
Journal Article
Open access
PDF file
CKCelestine Kathure Kinyua
Celestine Kathure Kinyua
AOAyub Omondi Owino
Ayub Omondi Owino
KKKawaljit Kaur
Kawaljit Kaur
DDDIPANKAR DAS
DIPANKAR DAS
NKNancy Karuri
Nancy Karuri
Holger SchönherrHolger Schönherr
Holger Schönherr
The rapid and selective detection of bacterial contaminations and bacterial infections in a non-laboratory setting using advanced sensing materials holds the promise to enable robust point-of-care tests and rapid diagnostics for applications in the medical field as well as food safety. Among the various possible analytes, bacterial enzymes have been targeted successfully in various sensing formats. In this current work, we focus on the systematic investigation of the role of surface area on the sensitivity in micro- and nanostructured autonomously reporting sensing hydrogel materials for the detection of bacterial enzymes. The colorimetric sensing materials for the detection of β-glucuronidase (ß-GUS) from Escherichia coli (E. coli) were fabricated by template replication of crosslinked pullulan acetoacetate (PUAA) and by electrospinning chitosan/polyethylene oxide nanofibers (CS/PEO NFs), both equipped with the chromogenic substrate 5-bromo-4-chloro-3-indolyl-β-D-glucuronide. The investigation of the dependence of the initial reaction rates on surface area unveiled a linear relationship of rate and thereby time to observe a signal for a given concentration of bacterial enzyme. This knowledge was exploited in nanoscale sensing materials made of CS/PEO NFs with diameters of 295 ± 100 nm. Compared to bulk hydrogel slabs, the rate of hydrolysis was significantly enhanced in NFs when exposed to bacteria suspension cultures and thus ensuring a rapid detection of living E. coli that produces the enzyme β-GUS. The findings afford generalized design principles for the improvement of known and novel sensing materials towards rapid detection of bacteria by nanostructuring in medical and food related settings.

8 December 2023 in Optics
Verified
Journal Article
Open access
PDF file
ATAmon Kipchirchir Too
Amon Kipchirchir Too
ESEvaggelos Sidiropoulos
Evaggelos Sidiropoulos
YHYannik Holz
Yannik Holz
NKNancy Karuri
Nancy Karuri
Thomas SeegerThomas Seeger
Thomas Seeger
Simultaneous gas phase temperature and water vapor concentration measurement are important to understand reacting flows such as combustion or gas reforming processes. Here, coherent anti-Stokes Raman scattering (CARS) offers the possibility for non-intrusive measurements with a high temporal and spatial resolution. Therefore, this work demonstrates the simultaneous measurement of temperature and relative water vapor–nitrogen concentrations by using dual-pump vibrational coherent anti-Stokes Raman scattering (DPVCARS). A calibration procedure is developed for a temperature range of 473 K to 673 K and a water vapor concentration of 24% to 46% at ambient pressure. This setup is tested with 500 CARS single pulse spectra taken in a gas cell at a known temperature and concentration. Based on these results, information about precision and accuracy can be delivered.