Xinqi Bao

Dr. Xinqi Bao

Engineering, King's College London, London, City of London, UK
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 March 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Xinqi BaoXinqi Bao
Xinqi Bao
YXYujia Xu
Yujia Xu
EKErnest N. Kamavuako
Ernest N. Kamavuako
Deep learning techniques are the future trend for designing heart sound classification methods, making conventional heart sound segmentation dispensable. However, despite using fixed signal duration for training, no study has assessed its effect on the final performance in detail. Therefore, this study aims at analysing the duration effect on the commonly used deep learning methods to provide insight for future studies in data processing, classifier, and feature selection. The results of this study revealed that (1) very short heart sound signal duration (1 s) weakens the performance of Recurrent Neural Networks (RNNs), whereas no apparent decrease in the tested Convolutional Neural Network (CNN) model was found. (2) RNN outperformed CNN using Mel-frequency cepstrum coefficients (MFCCs) as features. There was no difference between RNN models (LSTM, BiLSTM, GRU, or BiGRU). (3) Adding dynamic information (∆ and ∆²MFCCs) of the heart sound as a feature did not improve the RNNs’ performance, and the improvement on CNN was also minimal (≤2.5% in MAcc). The findings provided a theoretical basis for further heart sound classification using deep learning techniques when selecting the input length.

15 December 2022 in Computers in Biology and Medicine
Verified
Journal Article
Open access
YXYujia Xu
Yujia Xu
Hak Keung LamHak Keung Lam
Hak Keung Lam
GJGuangyu Jia
Guangyu Jia
JJJian Jiang
Jian Jiang
JLJunkai Liao
Junkai Liao
Xinqi BaoXinqi Bao
Xinqi Bao
The COVID-19 pandemic continues to spread rapidly over the world and causes a tremendous crisis in global human health and the economy. Its early detection and diagnosis are crucial for controlling the further spread. Many deep learning-based methods have been proposed to assist clinicians in automatic COVID-19 diagnosis based on computed tomography imaging. However, challenges still remain, including low data diversity in existing datasets, and unsatisfied detection resulting from insufficient accuracy and sensitivity of deep learning models. To enhance the data diversity, we design augmentation techniques of incremental levels and apply them to the largest open-access benchmark dataset, COVIDx CT-2A. Meanwhile, similarity regularization (SR) derived from contrastive learning is proposed in this study to enable CNNs to learn more parameter-efficient representations, thus improve the accuracy and sensitivity of CNNs. The results on seven commonly used CNNs demonstrate that CNN performance can be improved stably through applying the designed augmentation and SR techniques. In particular, DenseNet121 with SR achieves an average test accuracy of 99.44% in three trials for three-category classification, including normal, non-COVID-19 pneumonia, and COVID-19 pneumonia. The achieved precision, sensitivity, and specificity for the COVID-19 pneumonia category are 98.40%, 99.59%, and 99.50%, respectively. These statistics suggest that our method has surpassed the existing state-of-the-art methods on the COVIDx CT-2A dataset. Source code is available at https://github.com/YujiaKCL/COVID-CT-Similarity-Regularization.

25 December 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Xinqi BaoXinqi Bao
Xinqi Bao
AAAime Kingwengwe Abdala
Aime Kingwengwe Abdala
EKErnest N. Kamavuako
Ernest N. Kamavuako
The respiratory rate (RR) is a vital physiological parameter in prediagnosis and daily monitoring. It can be obtained indirectly from Electrocardiogram (ECG) signals using ECG-derived respiration (EDR) techniques. As part of the study in designing an early cardiac screening system, this work aimed to study whether the accuracy of ECG derived RR depends on the auscultation sites. Experiments were conducted on 12 healthy subjects to obtain simultaneous ECG (at auscultation sites and Lead I as reference) and respiration signals from a microphone close to the nostril. Four EDR algorithms were tested on the data to estimate RR in both the time and frequency domain. Results reveal that: (1) The location of the ECG electrodes between auscultation sites does not impact the estimation of RR, (2) baseline wander and amplitude modulation algorithms outperformed the frequency modulation and band-pass filter algorithms, (3) using frequency domain features to estimate RR can provide more accurate RR except when using the band-pass filter algorithm. These results pave the way for ECG-based RR estimation in miniaturised integrated cardiac screening device.

25 May 2023 in Biomedical Engineering Advances
Verified
Journal Article
Open access
Xinqi BaoXinqi Bao
Xinqi Bao
YXYujia Xu
Yujia Xu
HLHak-Keung Lam
Hak-Keung Lam
Mohamed TrabelsiMohamed Trabelsi
Mohamed Trabelsi
ICInes Chihi
Ines Chihi
EKErnest N. Kamavuako
Ernest N. Kamavuako


3 August 2021 in Sensors
Verified
Journal Article
Open access
PDF file
EKErnest N. Kamavuako
Ernest N. Kamavuako
MBMitchell Brown
Mitchell Brown
Xinqi BaoXinqi Bao
Xinqi Bao
ICInes Chihi
Ines Chihi
SPSamuel Pitou
Samuel Pitou
MHMatthew Howard
Matthew Howard
Commercial myoelectric prostheses are costly to purchase and maintain, making their provision challenging for developing countries. Recent research indicates that embroidered EMG electrodes may provide a more affordable alternative to the sensors used in current prostheses. This pilot study investigates the usability of such electrodes for myoelectric control by comparing online and offline performance against conventional gel electrodes. Offline performance is evaluated through the classification of nine different hand and wrist gestures. Online performance is assessed with a crossover two-degree-of-freedom real-time experiment using Fitts’ Law. Two performance metrics (Throughput and Completion Rate) are used to quantify usability. The mean classification accuracy of the nine gestures is approximately 98% for subject-specific models trained on both gel and embroidered electrode offline data from individual subjects, and 97% and 96% for general models trained on gel and embroidered offline data, respectively, from all subjects. Throughput (0.3 bits/s) and completion rate (95–97%) are similar in the online test. Results indicate that embroidered electrodes can achieve similar performance to gel electrodes paving the way for low-cost myoelectric prostheses.