Systemic lupus erythematosus is characterized by autoantibodies and immune complex deposition. Several autoantibodies against mainly nuclear autoantigens have been described. One of these nuclear autoantigens is the Smith antigen. In this review, we focus on the position of autoantibodies against the Smith antigen in the classification criteria, the characteristics of the antigen, the production of anti-Smith antibodies in SLE and we discuss the different test methods available, together with their pitfalls, to detect these autoantibodies.
Indirect immunofluorescence (IIF) on the human epithelial cell-line HEp-2 (or derivatives) serves as the gold standard in antinuclear antibody (ANA) screening. IIF, and its evaluation, is a labor-intensive method, making ANA testing a major challenge for present clinical laboratories. Nowadays, several automated ANA pattern recognition systems are on the market. In the current study, the EUROPattern Suite is evaluated for its use in daily practice in a routine setting. A total of 1033 consecutive routine samples was used to screen for ANA. Results (positive/negative ANA screening, pattern identification and titer) were compared between software-generated results (EUROPattern) and visual interpretation (observer) of automatically acquired digital images. Considering the visual interpretation as reference, a relative sensitivity of 99.3% and a relative specificity of 88.9% were obtained for negative and positive discrimination by the software (EPa). A good agreement between visual and software-based interpretation was observed with respect to pattern recognition (mean kappa: for 7 patterns: 0.7). Interestingly, EPa software distinguished more patterns per positive sample than the observer (on average 1.5 and 1.2, respectively). Finally, a concordance of 99.3% was observed within the range of 1 titer step difference between EPa and observer. The ANA IIF results reported by the EPa software are in very good agreement with the results reported by the observer with respect to being negative/positive, pattern recognition and titer, making automated ANA IIF evaluation an objective and time-efficient tool for routine testing.
1 January 2022 in The Journal of Applied Laboratory Medicine
Background: Primary biliary cholangitis (PBC), autoimmune hepatitis (AIH) and primary sclerosing cholangitis (PSC) are autoimmune liver diseases associated with distinct autoantibodies. Diagnosis is based upon clinical, serological, and histopathology findings. The role of autoantibodies in the diagnosis of these autoimmune liver diseases, with the focus on PBC and AIH, will be discussed. Content: When AIH or PBC is suspected, testing for multiple autoantibodies can be requested. In this mini-review, the different ways in which autoantibodies can be tested (indirect immunofluorescence and antigen-specific tests) in the context of PBC and AIH are discussed, as well as the pitfalls in interpreting the test results. Summary: For appropriate interpretation of test results, an important prerequisite is that the doctor knows which test is used in the laboratory of choice and that the laboratory specialist is aware of what the doctor wants to test for. Good communication between clinician and laboratory specialist can, therefore, aid in the diagnosis of autoimmune liver diseases.
Over the years, a wide variety of therapeutic antibodies has been successfully introduced in the auto-immunology clinic, and many more are on the way. Many of these treatments address either a pathogenic circulating molecule or a cell-bound molecule. Whereas addressing the former target results in neutralization of the soluble factor and binding to the latter target either inhibits cellular function or induces selective cell death. If this targeted molecule or cell is part of the immune system, this therapy evokes a state of immunodeficiency with infections as a possible consequence. Therefore, immune monitoring is needed to prevent such adverse side effects of immunotherapy. In this paper, different immunotherapies used in Sjögren’s syndrome, as well as different approaches to monitoring the immune system, are discussed.
29 August 2023 in Journal of Immunological Methods
Monoclonal gammopathies are characterized by the presence of monoclonal immunoglobulins, also known as M-proteins. Therapeutic monoclonal antibodies (t-mAbs) can interfere in laboratory assays used to monitor the state of disease, such as serum protein electrophoresis (SPE) and immunofixation electrophoresis (IFE). To establish a correct interpretation of IFE, Target protein-Collision Immunofixation Electrophoresis Reflex Assay (T-CIERA) was developed to identify t-mAbs in IFE. Here we demonstrate that T-CIERA is applicable to a wide variety of t-mAbs for which the target protein is commercially available. Moreover, the shift observed was characteristic for each t-mAb, and T-CIERA enabled the identification of multiple t-mAbs sharing a common target protein. Additionally, the lower limit of detection (LLOD) was determined objectively, and T-CIERA demonstrated an adequate LLOD for all tested t-mAbs. Furthermore, T-CIERA was also successfully applied to serum samples obtained from patients receiving daratumumab, isatuximab, elotuzumab, and durvalumab treatment. In conclusion, T-CIERA is a suitable reflex assay for identifying a wide variety of t-mAbs, including those for which no commercial assay is available to deal with their interference. Moreover, CD38-CIERA could serve as an alternative or complementary test to the commercially available Hydrashift assay kits. T-CIERA would enable laboratories without mass spectrometry equipment and expertise in this area to distinguish between drug and disease to improve clinical response monitoring and diagnosis of monoclonal gammopathies.