Murat Kuscu

Dr. Murat Kuscu

Department of Electrical and Electronics Engineering, Koc University, 34450 Istanbul, Turkey
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

17 November 2016 in Proceedings of the IEEE
Verified
Journal Article
Closed access
OAOzgur B. Akan
Ozgur B. Akan
HRHamideh Ramezani
Hamideh Ramezani
TKTooba Khan
Tooba Khan
NANaveed A. Abbasi
Naveed A. Abbasi
MKMurat Kuscu
Murat Kuscu
Molecular communication (MC) is the most promising communication paradigm for nanonetwork realization since it is a natural phenomenon observed among living entities with nanoscale components. Since MC significantly differs from classical communication systems, it mandates reinvestigation of information and communication theoretical fundamentals. The closest examples of MC architectures are present inside our own body. Therefore, in this paper, we investigate the existing literature on intrabody nanonetworks and different MC paradigms to establish and introduce the fundamentals of molecular information and communication science. We highlight future research directions and open issues that need to be addressed for revealing the fundamental limits of this science. Although the scope of this development encompasses wide range of applications, we particularly emphasize its significance for life sciences by introducing potential diagnosis and treatment techniques for diseases caused by dysfunction of intrabody nanonetworks.

18 January 2016 in IEEE Sensors Journal
Verified
Journal Article
Closed access
MKMurat Kuscu
Murat Kuscu
OAOzgur B. Akan
Ozgur B. Akan
Molecular communications, where molecules are used to encode, transmit, and receive information, are a promising means of enabling the coordination of nanoscale devices. The paradigm has been extensively studied from various aspects, including channel modeling and noise analysis. Comparatively little attention has been given to the physical design of molecular receiver and transmitter, envisioning biological synthetic cells with intrinsic molecular reception and transmission capabilities as the future nanomachines. However, this assumption leads to a discrepancy between the envisaged applications requiring complex communication interfaces and protocols, and the very limited computational capacities of the envisioned biological nanomachines. In this paper, we examine the feasibility of designing a molecular receiver, in a physical domain other than synthetic biology, meeting the basic requirements of nanonetwork applications. We first review the state-of-the-art biosensing approaches to determine whether they can inspire a receiver design. We reveal that the nanoscale field effect transistor-based electrical biosensor technology (bioFET) is particularly a useful starting point for designing a molecular receiver. Focusing on bioFET-based molecular receivers with a conceptual approach, we provide a guideline elaborating on their operation principles, performance metrics, and design parameters. We then provide a simple model for signal flow in silicon nanowire FET-based molecular receiver. Finally, we discuss the practical challenges of implementing the receiver and present the future research avenues from a communication theoretical perspective.

12 January 2018 in IEEE Transactions on Nanobioscience
Verified
Journal Article
Closed access
MKMurat Kuscu
Murat Kuscu
OAOzgur B. Akan
Ozgur B. Akan
Molecular Communication (MC) is a bio-inspired communication technique that uses molecules as a method of information transfer among nanoscale devices. MC receiver is an essential component having profound impact on the communication system performance. However, the interaction of the receiver with information bearing molecules has been usually oversimplified in modeling the reception process and developing signal detection techniques. In this paper, we focus on the signal detection problem of MC receivers employing receptor molecules to infer the transmitted messages encoded into the concentration of molecules, i.e., ligands. Exploiting the observable characteristics of ligand-receptor binding reaction, we first introduce a Maximum Likelihood (ML) detection method based on instantaneous receptor occupation ratio, as aligned with the current MC literature. Then, we propose a novel ML detection technique, which exploits the amount of time the receptors stay unbound in an observation time window. A comprehensive analysis is carried out to compare the performance of the detectors in terms of bit error probability (BEP). In evaluating the detection performance, emphasis is given to the receptor saturation problem resulting from the accumulation of messenger molecules at the receiver as a consequence of intersymbol interference (ISI). The results reveal that detection based on receptor unbound time is quite reliable even in saturation, whereas the reliability of detection based on receptor occupation ratio substantially decreases as the receiver gets saturated. Lastly, we also discuss the potential methods of implementing the detectors.

1 June 2015 in IEEE Internet of Things Journal
Verified
Journal Article
Closed access
MKMurat Kuscu
Murat Kuscu
OAOzgur B. Akan
Ozgur B. Akan
Molecular devices, which consist of single or a few molecules, are envisioned to perform advanced tasks such as molecular information processing and collaborative sensing/actuating if they are operated in a cooperative manner. To connect these nanoscopic primitive devices with each other and with macroscale networks, and thus, to realize the internet of molecular devices, requires fundamentally different and novel approaches, other than the molecular or electromagnetic nanocommunications. Recently, we proposed and studied the use of Förster resonance energy transfer (FRET), which is a short-range nonradiative energy transfer process between fluorophores, as a high-rate and reliable wireless communication mechanism to connect fluorophore-based photoactive molecular devices. In this paper, we provide an in-depth architectural view of this new communication paradigm with a focus on its peculiarities, fundamental principles, and design requirements by comprehensively surveying the theoretical and experimental positions and ideas. We give an overview of networking opportunities offered by the intrinsic capabilities of fluorophores under the novel concept of Internet of Molecular Things. We present some prospective applications, theoretical modeling approaches, and experimental opportunities, and finally discuss the implementation challenges.

7 February 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MKMurat Kuscu
Murat Kuscu
OAOzgur B. Akan
Ozgur B. Akan
We consider a microfluidic molecular communication (MC) system, where the concentration-encoded molecular messages are transported via fluid flow-induced convection and diffusion, and detected by a surface-based MC receiver with ligand receptors placed at the bottom of the microfluidic channel. The overall system is a convection-diffusion-reaction system that can only be solved by numerical methods, e.g., finite element analysis (FEA). However, analytical models are key for the information and communication technology (ICT), as they enable an optimisation framework to develop advanced communication techniques, such as optimum detection methods and reliable transmission schemes. In this direction, we develop an analytical model to approximate the expected time course of bound receptor concentration, i.e., the received signal used to decode the transmitted messages. The model obviates the need for computationally expensive numerical methods by capturing the nonlinearities caused by laminar flow resulting in parabolic velocity profile, and finite number of ligand receptors leading to receiver saturation. The model also captures the effects of reactive surface depletion layer resulting from the mass transport limitations and moving reaction boundary originated from the passage of finite-duration molecular concentration pulse over the receiver surface. Based on the proposed model, we derive closed form analytical expressions that approximate the received pulse width, pulse delay and pulse amplitude, which can be used to optimize the system from an ICT perspective. We evaluate the accuracy of the proposed model by comparing model-based analytical results to the numerical results obtained by solving the exact system model with COMSOL Multiphysics.