This study proposed a deep reinforcement learning-based energy management strategy (DRL-EMS) that can be applied to a hybrid electric ship propulsion system (HSPS) integrating liquid hydrogen (LH2) fuel gas supply system (FGSS), proton-exchange membrane fuel cell (PEMFC) and lithium-ion battery systems. This study analyzed the optimized performance of the DRL-EMS and the operational strategy of the LH2-HSPS. To train the proposed DRL-EMS, a reward function was defined based on fuel consumption and degradation of power sources during operation. Fuel consumption for ship propulsion was estimated with the power for balance of plant (BOP) of the LH2 FGSS and PEMFC system. DRL-EMS demonstrated superior global and real-time optimality compared to benchmark algorithms, namely dynamic programming (DP) and sequential quadratic programming (SQP)-based EMS. For various operation cases not used in training, DRL-EMS resulted in 0.7% to 9.2% higher operating expenditure compared to DP-EMS. Additionally, DRL-EMS was trained to operate 60% of the total operation time in the maximum efficiency range of the PEMFC system. Different hydrogen fuel costs did not affect the optimized operational strategy although the operating expenditure (OPEX) was dependent on the hydrogen fuel cost. Different capacities of the battery system did not considerably change the OPEX.
This study analyzes the thermodynamic, economic, and regulatory aspects of boil-off hydrogen (BOH) in liquid hydrogen (LH2) carriers that can be re-liquefied using a proposed re-liquefaction system or used as fuel in a fuel cell stack. Five LH2 carriers sailing between two designated ports are considered in a case study. The specific energy consumption of the proposed re-liquefaction system varies from 8.22 to 10.80 kWh/kg as the re-liquefaction-to-generation fraction (R/G fraction) is varied. The economic evaluation results show that the cost of re-liquefaction decreases as the re-liquefied flow rate increases and converges to 1.5 $/kg at an adequately large flow rate. Three energy efficient design index (EEDI) candidates are proposed to determine feasible R/G fractions: an EEDI equivalent to that of LNG carriers, an EEDI that considers the energy density of LH2, and no EEDI restrictions. The first EEDI candidate is so strict that the majority of the BOH should be used as fuel. In the case of the second EEDI candidate, the permittable R/G fraction is between 25% and 33%. If the EEDI is not applied for LH2 carriers, as in the third candidate, the specific life-cycle cost decreases to 67% compared with the first EEDI regulation.
1 November 2021 in International Journal of Hydrogen Energy