Koichi Morota

Dr. Koichi Morota

Shinkomonji hospital

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 February 2025 in Journal of Bone and Joint Surgery
Verified
Journal Article
Open access
YHYasukazu Hijikata
Yasukazu Hijikata
KYKazuta Yamashita
Kazuta Yamashita
NHNatsuko Hatsusaka
Natsuko Hatsusaka
TNTatsuo Nagata
Tatsuo Nagata
HKHiroko Kitamura
Hiroko Kitamura
TMTakashi Moritake
Takashi Moritake
Background: The impact of radiation exposure on cataracts and hand skin cancer in orthopaedic and spine surgeons remains understudied. This study aimed to investigate the prevalence of cataracts and chronic hand inflammation in orthopaedic and spine surgeons and to assess their association with radiation exposure. Methods: A cross-sectional analysis was conducted on orthopaedic and spine surgeons attending the 38th Annual Meeting of the Neurospinal Society of Japan or the 31st Annual Meeting of the Japanese Society for the Study of Low Back Pain. Cataractous changes were categorized into none, lens micro-opacity, or cataracts and were detailed alongside the prevalence of chronic hand inflammation, which included longitudinal melanonychia and hand eczema. Participants were divided into quartiles according to hand-exposure opportunities in the operating and fluoroscopy rooms in 2022. Prevalence ratios and 95% confidence intervals (CIs) of chronic hand inflammation in the upper quartiles relative to the first quartile were calculated using modified Poisson regression adjusted for potential confounders. Results: The median work experience of the 162 participants was 23 years, and the median number of hand-exposure opportunities was 70 (interquartile range [IQR], 20 to 123) in the operating room and 20 (IQR, 0 to 60) in the fluoroscopy room. The prevalence of cataracts was 20% (32 participants), and the prevalence of cataractous changes, including lens micro-opacity, was 40% (64 participants). Chronic hand inflammation was present in 62 participants (38%), of whom 52 had longitudinal melanonychia and 23 had hand eczema. The adjusted prevalence ratios of chronic hand inflammation relative to the lowest quartile of hand-exposure opportunities in the operating room were 0.91 (0.50, 1.66) for quartile 2, 0.72 (0.41, 1.25) for quartile 3, and 1.56 (0.97, 2.50) for quartile 4. For fluoroscopy room exposure, the adjusted prevalence ratios were 2.31 (1.16, 4.58) for quartile 2, 2.03 (1.00, 4.09) for quartile 3, and 2.94 (1.51, 5.75) for quartile 4. Conclusions: This study highlighted substantial cataractous and chronic hand inflammatory changes in spine surgeons, indicating indirect and direct radiation exposure effects. Therefore, radiation safety and protective measures must be emphasized. Comparative studies with other populations and longitudinal observations are required to better understand the effects of radiation on health. Level of Evidence: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.

10 March 2023 in Medicina
Verified
Journal Article
Open access
PDF file
YHYasukazu Hijikata
Yasukazu Hijikata
Yoshihisa KotaniYoshihisa Kotani
Yoshihisa Kotani
Akinobu SuzukiAkinobu Suzuki
Akinobu Suzuki
KMKoichi Morota
Koichi Morota
HFHaruki Funao
Haruki Funao
KIKen Ishii
Ken Ishii
Background and Objectives: The global trend toward increased protection of medical personnel from occupational radiation exposure requires efforts to promote protection from radiation on a societal scale. To develop effective educational programs to promote radiation protection, we clarify the actual status and stage of behavioral changes of spine surgeons regarding radiation protection. Materials and Methods: We used a web-based questionnaire to collect information on the actual status of radiation protection and stages of behavioral change according to the transtheoretical model. The survey was administered to all members of the Society for Minimally Invasive Spinal Treatment from 5 October to 5 November 2020. Results: Of 324 members of the Society for Minimally Invasive Spinal Treatment, 229 (70.7%) responded. A total of 217 participants were analyzed, excluding 12 respondents who were not exposed to radiation in daily practice. A trunk lead protector was used by 215 (99%) participants, while 113 (53%) preferred an apron-type protector. Dosimeters, thyroid protector, lead glasses, and lead gloves were used by 108 (50%), 116 (53%), 82 (38%), and 64 (29%) participants, respectively. While 202 (93%) participants avoided continuous irradiation, only 120 (55%) were aware of the source of the radiation when determining their position in the room. Regarding the behavioral change stage of radiation protection, 134 (62%) participants were in the action stage, while 37 (17%) had not even reached the contemplation stage. Conclusions: We found that even among the members of the Society for Minimally Invasive Spinal Treatment, protection of all vulnerable body parts was not fully implemented. Thus, development of educational programs that cover the familiar risks of occupational radiation exposure, basic protection methods in the operating room, and the effects of such protection methods on reducing radiation exposure in actual clinical practice is warranted.

5 August 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
KNKoichi Nakagami
Koichi Nakagami
TMTakashi Moritake
Takashi Moritake
KNKeisuke Nagamoto
Keisuke Nagamoto
KMKoichi Morota
Koichi Morota
SMSatoru Matsuzaki
Satoru Matsuzaki
NKNaoki KUNUGITA
Naoki KUNUGITA
A short curtain that improves on the low versatility of existing long curtains was developed as a dedicated radiation protective device for the over-table tube fluorographic imaging units. The effect of this short curtain in preventing cataracts was then examined. First, the physician lens dose reduction rate was obtained at the position of the lens. Next, the reduction rate in the collective equivalent dose for the lens of the physician’s eye was estimated. The results showed that lens dose reduction rates with the long curtain and the short curtain were 88.9% (literature-based value) and 17.6%, respectively, higher with the long curtain. In our hospital, the reduction rate in the collective equivalent dose for the lens of the physician’s eye was 9.8% and 17.6% with a procedures mixture, using the long curtain where technically possible and no curtain in all other procedures, and the short curtain in all procedures, respectively, higher with the short curtain. Moreover, a best available for curtains raised the reduction rate in the collective equivalent dose for the lens of the physician’s eye a maximum of 25.5%. By introducing the short curtain, it can be expected to have an effect in preventing cataracts in medical staff.

10 February 2024 in Nursing Reports
Verified
Journal Article
Open access
PDF file
TKTomoko Kuriyama
Tomoko Kuriyama
TMTakashi Moritake
Takashi Moritake
KNKoichi Nakagami
Koichi Nakagami
KMKoichi Morota
Koichi Morota
GHGo Hitomi
Go Hitomi
HKHiroko Kitamura
Hiroko Kitamura
With the International Commission on Radiological Protection’s (ICRP) reduction in the radiation dose threshold for cataracts, evaluating and preventing radiation exposure to the lens of the eye among interventional radiology (IR) staff have become urgent tasks. In this study, we focused on differences in lens-equivalent dose (HT Lens) to which IR nurses in three hospitals were exposed and aimed to identify factors underlying these differences. According to analyses of time-, distance-, and shielding-related factors, the magnitude of the HT Lens dose to which IR nurses were exposed could be explained not by time or shielding but by the distance between the X-ray exposure field and the location of the IR nurse. This distance tended to be shorter in hospitals with fewer staff. The most effective means of reducing the exposure of the lenses of IR nurses’ eyes to radiation is to position them at least two meters from the radiation source during angiography procedures. However, some hospitals must provide IR departments with comparatively few staff. In work environments where it is infeasible to reduce exposure by increasing distance, interventions to reduce time by managing working practices and investment in shielding equipment are also important. This study was not registered.

SMSatoru Matsuzaki
Satoru Matsuzaki
TMTakashi Moritake
Takashi Moritake
LSLue Sun
Lue Sun
KMKoichi Morota
Koichi Morota
KNKeisuke Nagamoto
Keisuke Nagamoto
NKNaoki KUNUGITA
Naoki KUNUGITA
Interventional radiology (IR) physicians must be equipped with personal passive dosimeters and personal protective equipment (PPE); however, they are inconsistently used. Therefore, we aimed to explore practical measures to increase PPE usage and ascertain whether these measures could lead to an actual decrease in exposure doses to IR physicians. Dosimeters and PPE were visually inspected. Then, a pre-operative briefing was conducted as a direct intervention, and the use of dosimeters and PPE was verbally confirmed. Finally, the intervention effect was verified by measuring the use rates and individual exposure doses. Because of the intervention, the use rate markedly improved and was almost 100%. However, both the effective dose rate (effective dose/fluoroscopy time) and the lens equivalent dose rate (lens equivalent dose/fluoroscopy time) showed that the intervention led to a statistically significant increase in exposure (effective dose rate: p = 0.033; lens equivalent dose rate: p = 0.003). In conclusion, the proper use of dosimeters and PPE raised the radiation exposure values for IR physicians immediately after the intervention, which was hypothesized to be due to the inclusion of exposure overlooked to date and the changes in the dosimeter management method from a single- to a double-dosimeter approach.

23 December 2020 in Diagnostics
Verified
Journal Article
Open access
PDF file
KMKoichi Morota
Koichi Morota
TMTakashi Moritake
Takashi Moritake
KNKeisuke Nagamoto
Keisuke Nagamoto
SMSatoru Matsuzaki
Satoru Matsuzaki
KNKoichi Nakagami
Koichi Nakagami
NKNaoki KUNUGITA
Naoki KUNUGITA
Understanding the maximum skin dose is important for avoiding tissue reactions in cerebral angiography. In this study, we devised a method for using digital imaging and communication in medicine—radiation dose structured report (DICOM-RDSR) data to accurately estimate the maximum skin dose from the total air kerma at the patient entrance reference point (Total Ka,r). Using a test data set (n = 50), we defined the mean ratio of the maximum skin dose obtained from measurements with radio-photoluminescence glass dosimeters (RPLGDs) to the Total Ka,r as the conversion factor, CFKa,constant, and compared the accuracy of the estimated maximum skin dose obtained from multiplying Total Ka,r by CFKa,constant (Estimation Model 1) with that of the estimated maximum skin dose obtained from multiplying Total Ka,r by the functional conversion factor CFKa,function (Estimation Model 2). Estimation Model 2, which uses the quadratic function for the ratio of the fluoroscopy Ka,r to the Total Ka,r (Ka,r ratio), provided an estimated maximum skin dose closer to that obtained from direct measurements with RPLGDs than compared with that determined using Estimation Model 1. The same results were obtained for the validation data set (n = 50). It was suggested the quadratic function for the Ka,r ratio provides a more accurate estimate of the maximum skin dose in real time.