sen wu

Dr. sen wu

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 April 2019 in Micromachines
Verified
Journal Article
Open access
PDF file
SWsen wu
sen wu
ZLZhijian Liu
Zhijian Liu
HYHaichao Yuan
Haichao Yuan
KYKezhen Yu
Kezhen Yu
YGYuefeng Gao
Yuefeng Gao
XPXinxiang Pan
Xinxiang Pan
Inductive wear debris sensor has been widely used in real time machine lubricant oil condition monitoring and fault forecasting. However, the small sensing zone, which is designed for high sensitivity, of the existing sensors leads to low throughput. In order to improve the throughput, a novel multichannel wear debris sensor that is based on phase division multiplexing is presented. By introducing the phase shift circuit into the system, multiple sensing coils could work at different initial phases. Multiple signals of sensing coils could be combined into one output without information loss. Synchronized sampling is used for data recording, and output signals of multiple sensing coils are extracted from the recorded data. A four-channel wear debris sensor system was designed to demonstrate our method. Subsequently, crosstalk analysis, pseudo-dynamic testing and dynamic testing were conducted to check the sensing system. Results show that signals of four sensing coils could be simultaneously detected and the detection limit for ferrous wear debris is 33 μm. Using the presented method, real time wear debris detection in multiple channels could be achieved without increasing the number of excitation source and data acquisition equipment.

4 March 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
SWsen wu
sen wu
ZLZhijian Liu
Zhijian Liu
KYKezhen Yu
Kezhen Yu
ZFZixiao Fan
Zixiao Fan
ZYZiyi Yuan
Ziyi Yuan
XPXinxiang Pan
Xinxiang Pan
Inductive wear debris sensor has been proved to be an effective device for lubricant oil condition monitoring and fault diagnosis. However, the narrow internal diameter of current sensing coil, designed for high sensitivity, limits the oil throughput. To improve the throughput without sacrificing the sensitivity, a novel multichannel wear debris detection method based on time division multiplexing is presented in this work. Only one excitation signal is used to excite multiple sensing coils. Then, the signals from multiple sensing coils are combined with a serials of square waves separately, which are self-designed specially. As a result, the peak waveforms are lifted in different timeslots by the high-level voltages in squares waves. After that, the peaks of the signals are cut out and combined into one output signal. Then, we used synchronized sampling method to record the peak values of the output signal. The signals for all sensing channels are finally extracted from the recorded peak values. To validate the feasibility of the proposed method, we designed a ten-channel sensor system using time division multiplexing. Through the pseudo-dynamic and dynamic test, it is proved that the sensor could detect wear debris in different channels simultaneously and independently without sacrificing the sensitivity. In addition, the proposed method has the potential to integrate more channels into one system, which would contribute to high throughput real time lubricant oil detection.

5 October 2022 in Energies
Verified
Journal Article
Open access
PDF file
ZLZhijian Liu
Zhijian Liu
SWsen wu
sen wu
MRMahmud Kamal Raihan
Mahmud Kamal Raihan
DZDiyu Zhu
Diyu Zhu
KYKezhen Yu
Kezhen Yu
XPXinxiang Pan
Xinxiang Pan
Wear debris in lubrication oil provides important information for marine engine condition monitoring and faults diagnosis. Inductive sensors have been widely used to detect wear debris in lubrication oil. To improve the sensitivity, the inductive coil is always connected with a capacitor in parallel to form parallel LC resonance-sensing circuit. A previous study optimized the parallel resonance circuit by adjusting the excitation frequency. However, multiple parameters (namely, excitation signal, signal detection circuits, and signal-processing program, etc.) need to be adjusted accordingly for a series of the testing frequencies. To simplify the optimization, we propose a method based on adjusting the parallel capacitance in this work. The impedance (inductance and internal resistance) of the sensing coil and its variation induced by particles are first measured, which are the necessary parameters for establishing the function relationship between the parallel capacitance and the relative impedance variation. With the function relationship, the relative impedance variation is calculated directly, and the optimal capacitance is located at the highest absolute value of it. The experimental results for the ferrous and nonferrous particles match the calculation results well. Interestingly, the optimal capacitance for the nonferrous particle was larger than that of the ferrous particle. We speculate that the difference is generated due to the increased resistance induced by the eddy current effect.

1 July 2019 in Micromachines
Verified
Journal Article
Open access
PDF file
LLLiankun Liu
Liankun Liu
LCLiang Chen
Liang Chen
SWSaijie Wang
Saijie Wang
YYYin Yi
Yin Yi
DLDazhuang Liu
Dazhuang Liu
XPXinxiang Pan
Xinxiang Pan
The inductive detection of wear debris in lubrication oil is an effective method to monitor the machine status. As the wear debris is usually micro scale, a micro inductive sensor is always used to detect them in research papers or high-tech products. However, the improvement of detection sensitivity for micro inductive sensors is still a great challenge, especially for early wear debris of 20 μm or smaller diameter. This paper proposes a novel method to improve the detection sensitivity of a micro inductive sensor. Regarding the magnetic powder surrounding the sensor, the magnetic field in the core of the sensor where the wear debris pass through would be enhanced due to the increased relative permeability. Thus, the inductive signal would be improved and the detection sensitivity would be increased. It is found that the inductive signal would linearly increase with increasing the concentration of the magnetic powder and this enhancement would also be effective for wear debris of different sizes. In addition, the detection limit of the micro inductive sensor used in our experiment could be extended to 11 μm wear debris by the proposed method.

14 November 2019 in Sensors
Verified
Journal Article
Open access
PDF file
YYYin Yi
Yin Yi
ZLZhijian Liu
Zhijian Liu
JZJie Zheng
Jie Zheng
LCLiang Chen
Liang Chen
SWsen wu
sen wu
XPXinxiang Pan
Xinxiang Pan
Wear debris detection is an effective method to determine the running state of the machine. Recently, the planar inductor is commonly used to detect wear debris. The previous studies have found that the inductive signal would be varied while changing the position of wear debris pass through. However, the effect of position on the wear debris detection is not well understood. In this paper, a novel detection system in which the position of wear debris pass through could be adjusted precisely is designed. By changing the position in horizontal or vertical direction, the inductive signals of the wear debris were acquired. In the horizontal direction, the experimental results show that the amplitude of the inductive signal first increases and then decreases when the position changes from the center of the planar inductor to the outer. The maximum inductive signal appears when the wear debris pass through the edge of the inner coil, which is 20% higher than that for the center and much higher than that for the edge of outer coil. In the vertical direction, the signal decreases almost linearly when the position is away from the planar inductor. For every 0.1 mm step far away the planar inductor, the signal amplitude drops by approximately 10%. The variation trend of our experimental results is consistent with the numerical simulation results of magnetic intensity around the planar inductor.

29 June 2022 in Sensors
Verified
Journal Article
Open access
PDF file
FWFeng Wang
Feng Wang
ZLZhijian Liu
Zhijian Liu
XRXiaojing Ren
Xiaojing Ren
SWsen wu
sen wu
MMMeilin Meng
Meilin Meng
XPXinxiang Pan
Xinxiang Pan
Inductance detection is an important method for detecting wear debris in ship lubricating oil. Presently, an LCR (inductance, resistance, capacitance) meter is generally used to detect wear debris by measuring the inductance change of the sensing coil. When ferromagnetic debris passes through the sensing coil, a pulse will appear in the inductance signal. Previous studies have shown that the amplitude of the inductance pulse decreases significantly with the increase in the particles’ velocity. Therefore, it is difficult to detect ferromagnetic debris with a high flow velocity using an LCR meter. In this paper, a novel method, high-frequency voltage acquisition (HFVA), is proposed to detect ferromagnetic debris. Different from previous methods, the wear debris was detected directly by measuring the voltage change of the sensing coil, while the synchronized sampling method was utilized to ensure the higher-frequency acquisition of the sensor output signal. The experimental results show that when the velocity of particles increased from 6 mm/s to 62 mm/s, the amplitude of the signal pulse obtained by HFVA decreased by only 13%, which was much lower than the 85% obtained by utilizing the LCR method.