Implants made of ceramic and metallic elements, which are used in dentistry, may either promote or hinder the colonization and adhesion of bacteria to the surface of the biomaterial to varying degrees. The increased interest in the use of dental implants, especially in patients with chronic systemic diseases such as cystic fibrosis (CF), is caused by an increase in disease complications. In this study, we evaluated the differences in the in vitro biofilm formation on the surface of biomaterials commonly used in dentistry (Ti-6Al-4V, cobalt-chromium alloy (CoCr), and zirconia) by Staphylococcus aureus isolated from patients with CF. We demonstrated that S. aureus adherence and growth depends on the type of material used and its surface topography. Weaker bacterial biofilm formation was observed on zirconia surfaces compared to titanium and cobalt-chromium alloy surfaces. Moreover, scanning electron microscopy showed clear differences in bacterial aggregation, depending on the type of biomaterial used. Over the past several decades, S. aureus strains have developed several mechanisms of resistance, especially in patients on chronic antibiotic treatment such as CF. Therefore, the selection of an appropriate implant biomaterial with limited microorganism adhesion characteristics can affect the occurrence and progression of oral cavity infections, particularly in patients with chronic systemic diseases.
Human milk fat plays an essential role as the source of energy and cell function regulator; therefore, the preservation of unique human milk donors’ lipid composition is of fundamental importance. To compare the effects of high pressure processing (HPP) and holder pasteurization on lipidome, human milk was processed at 62.5 °C for 30 min and at five variants of HPP from 450 MPa to 600 MPa, respectively. Lipase activity was estimated with QuantiChrom™ assay. Fatty acid composition was determined with the gas chromatographic technique, and free fatty acids content by titration with 0.1 M KOH. The positional distribution of fatty acid in triacylglycerols was performed. The oxidative induction time was obtained from the pressure differential scanning calorimetry. Carotenoids in human milk were measured by liquid chromatography. Bile salt stimulated lipase was completely eliminated by holder pasteurization, decreased at 600 MPa, and remained intact at 200 + 400 MPa; 450 MPa. The fatty acid composition and structure of human milk fat triacylglycerols were unchanged. The lipids of human milk after holder pasteurization had the lowest content of free fatty acids and the shortest induction time compared with samples after HPP. HPP slightly changed the β-carotene and lycopene levels, whereas the lutein level was decreased by 40.0% up to 60.2%, compared with 15.8% after the holder pasteurization.
Background: Human milk banks have a pivotal role in provide optimal food for those infants who are not fully breastfeed, by allowing human milk from donors to be collected, processed and appropriately distributed. Donor human milk (DHM) is usually preserved by Holder pasteurization, considered to be the gold standard to ensure the microbiology safety and nutritional value of milk. However, as stated by the European Milk Banking Association (EMBA) there is a need to implement the improvement of the operating procedure of human milk banks including preserving and storing techniques. Aim: The purpose of this study was to assess the effectiveness and safety of the selected new combination of methods for preserving donor human milk in comparison with thermal treatment (Holder pasteurization). Methods: We assessed (1) the concentration of bioactive components (insulin, adiponectin, leptin, activity of pancreatic lipase, and hepatocyte growth factor) and (2) microbiological safety in raw and pasteurized, high-pressure processed and lyophilization human breast milk. Results: The combination of two techniques, high-pressure processing and freeze-drying, showed the best potential for preserving the nutritional value of human milk and were evaluated for microbiological safety. Microbiological safety assessment excluded the possibility of using freeze-drying alone for human milk sample preservation. However, it can be used as a method for long-term storage of milk samples, which have previously been preserved via other processes. Conclusion: The results show that high-pressure treatment is the best method for preservation that ensures microbiological safety and biological activity but subsequent freeze-drying allowed long-term storage without loss of properties.
Cystic fibrosis is an inherited disease that affects multiple organs and systems. The oral cavity can serve as a substantial source of bacteria, causing respiratory infections and diseases which continue to dictate the clinical course of the disease and prognosis in patients with CF. Low voltage and electric current could effectively kill bacteria and biofilms, and the activity of milliampere currents could be used as an effective method of fighting bacteria. This study evaluated the effect of low amperage electric current on the formation of Staphylococcus aureus biofilms on dental implants such as titanium and zirconium in patients with cystic fibrosis. Our studies suggest that a constant electric current at a low intensity of 1 mA and 10 mA is inhibiting bacterial adhesion, detaching biofilm-forming bacteria on biomaterials used in dental implants such as titanium and zirconium, and destroying bacterial cells of Staphylococcus aureus strains. In addition, we observed the selection of an appropriate biomaterial for implants in people affected by chronic diseases, such as CF, should be carefully planned.
As the survival rate for preterm infants increases, more emphasis is placed on improving health-related quality of life through optimal nutritional management. Human Milk Banks (HMBs) provide bioactive nutrients and probiotic microorganisms to premature newborns, especially in the first year of life. Donated milk screening and selection of potential donors ensures the quality and microbiological safety of the donated milk. Therefore we reviewed the basic characteristics of donors and the amounts and contamination of breast milk donated to the Regional Human Milk Bank (RHMB) in Warsaw. In four years, the RHMB collected 1445.59 L of milk, of which 96.60% was distributed among hospitalised infants. Additionally, breastmilk from donor candidates (139 samples from 96 women) was tested at least once in the first year of lactation. First analyses showed that 18 women’s milk samples were microbiologically pure, and 78 samples had one or more species of commensal and/or potentially pathogenic bacteria. In human milk samples from 10 women, the bacteria level was above the standard required by the RHMB; therefore, donors were re-educated, and further samples were tested. Most women followed the recommendations on hygienic expression and storage of milk before transfer to the RHMB. Our analysis will help to increase the accessibility and quality of raw donor milk and to meet the needs of more newborns.
The common use of dental implants for dental reconstruction poses new treatment challenges for physicians, peri-implantitis being a particularly difficult one. Micro-organisms, including drug-resistant Staphylococcus spp. strains, play a crucial role in the etiology of peri-implantitis. In this paper, the authors assess the efficacy of a bioactive healing abutment (BHA) of their own design for the local release of antibiotics as a potential tool for the treatment of peri-implant disease. BHA filled with a collagen material, combined with the antibiotics clindamycin and tetracycline, was tested in vitro by disk diffusion assay. Antibacterial activity was observed for the chosen Staphylococcus aureus and Staphylococcus epidermidis bacterial strains. In addition, the impact of titanium discs (which were used to make the BHA) was monitored. The results show that the zone diameter breakpoints for BHA are higher than those of standard absorbent paper discs in both tested strains for both tested antibiotics. This work demonstrates that the proposed BHA can serve as an effective and precise drug carrier. The release of antibiotics from the described implant device is easy to control and allows for an effective local antibacterial in vitro treatment. The procedure is inexpensive, easy to perform, and repeatable.