Despite rapid advances in artificial intelligence (AI) capabilities, clinical integration remains limited, partly due to an incomplete understanding of physicians' real-world engagement and determinants of adoption. We conducted an international cross-sectional survey between June and September 2024 using a 30-item questionnaire translated into 13 languages, analysing 1049 complete responses from 50 countries and territories. Most respondents reported fundamental to advanced understanding of AI (86.5%) and believed it would improve clinical practice (80.2%), particularly in efficiency (53.5%), timeliness (52.0%), and effectiveness (44.0%). However, only 27.8% had used AI in practice, and 17.7% had received formal training. Mann-Whitney analyses showed that positive attitudes and formal training were associated with greater AI understanding, familiarity and usage (all p ≤ 0.008). In multivariable regression, physicians with formal training were more than three times as likely to use AI (adjusted OR 3.40; 95% CI 2.31-5.01; p < 0.001), and those working in institutions with AI technologies were more than eight times as likely (adjusted OR 8.43; 95% CI 5.74-12.34; p < 0.001). These findings indicate a persistent gap between awareness and adoption driven primarily by structural factors, particularly the absence of formal AI training and limited institutional investment in AI technologies.
Wearable ward monitoring must eventually detect when a patient leaves the bed, yet the brief postural transitions that begin a bed exit are under-examined relative to dynamic activities. As a feasibility study, we used a public waist-worn six-axis inertial dataset (30 healthy subjects) to ask which sensor axes carry these transitions and whether a pretrained foundation model helps. We defined a ten-class task of four basic activities and six directional transitions, treating the two lie-to-upright transitions as the bed-exit-relevant classes, evaluated with subject-grouped cross-validation. Postural transitions were the weakest classes, and the weakest of these was a bed-exit transition. Removing the gyroscope reduced macro-F1 from 0.822 to 0.647 and bed-exit F1 from 0.657 to 0.351 (p < 10−4) while leaving lying and walking unaffected. The mirror ablation separated the roles: the accelerometer captured posture and the gyroscope captured every directional transition. A six-axis hand-crafted model outperformed one accelerometer-only foundation model even after full fine-tuning (0.822 vs. 0.774) with far fewer labels. Scoring windows that cross bout boundaries lowered bed-exit sensitivity from 0.937 to 0.833. Among the configurations tested, sensor choice, the gyroscope in particular, mattered more than model scale. These results concern transition recognition in scripted recordings, not bed-exit detection on a ward.