A novel sensing system has been designed for the detection of cupric ions. It is based on the quenched fluorescence signal of carbon dots (CDs), which were carbonized from poly(vinylpyrrolidone) (PVP) and L-Cysteine (CYS). Cupric ions interact with the nitrogen and sulfur atoms on surface of the CDs to form an absorbed complex; this results in strong quenching of the fluorescence of the CDs via a fast metal-to-ligand binding affinity. The synthesized water-soluble CDs also exhibited a quantum yield of 7.6%, with favorable photoluminescent properties and good photostability. The fluorescence intensity of the CDs was very stable in high ionic strength (up to 1.0 M NaCl) and over a wide range of pH levels (2.0–12.0). This facile method can therefore develop a sensor that offers reliable, fast, and selective detection of cupric ions with a detection limit down to 0.15 μM and a linear range from 0.5 to 7.0 μM (R2 = 0.980). The CDs were used for cell imaging, observed that they were low toxicity to Tramp C1 cells and exhibited blue and green and red fluorescence under a fluorescence microscope. In summary, the CDs exhibited excellent fluorescence properties, and could be applied to the selective and sensitive detection of cupric ion and multicolor cell imaging.
Nitrogen and sulfur codoped carbon dots (NSCDs) were synthesized via a one-pot hydrothermal method, and citric acid, ethylenediamine, and methyl blue were used as precursors. The obtained NSCDs were spherical with an average size of 1.86 nm. The fluorescence emission spectra of the NSCDs were excitation independent and emitted blue fluorescence at 440 nm with an excitation wavelength at 350 nm. The quantum yield of the NSCDs was calculated to be 68.0%. The NSCDs could be constructed as fluorescent probes for highly selective and sensitive sensing mercuric (Hg2+) and hypochlorite (ClO−) ions. As the addition of Hg2+ or ClO− ions to the NSCDs, the fluorescence intensity was effectively quenched due to dynamic quenching. Under the optimal conditions, the linear response of the fluorescence intensity ranged from 0.7 μM to 15 μM with a detection limit of 0.54 μM and from 0.3 μM to 5.0 μM with a limit of detection of 0.29 μM for Hg2+ and ClO− ions, respectively. Finally, the proposed method was successfully used for quantifying Hg2+ and ClO− ions in spiked tap water samples.
In the proposed study, an efficient method for a carbon dot@β-cyclodextrin (C-dot@β-CD)-based fluorescent probe was developed for the analyses of catechol (CC) and hydroquinone (HQ) at trace levels in water samples.